APC MGE Galaxy 3500 UPS G35T15K3I3B4S

APC MGE Galaxy 3500 UPS G35T15K3I3B4S
share

Specifications:
Output
Output Power Capacity 12 kW / 15 kVA
Max Configurable Power 12 kW / 15 kVA
Nominal Output Voltage 230V
Efficiency at Full Load 95.5%
Output Voltage Distortion Less than 5%
Output Frequency (sync to mains) 47 - 53 Hz for 50 Hz nominal
Other Output Voltages 220, 240
Crest Factor Unlimited
Topology Double Conversion Online
Waveform Type Sine wave
Output Connections
(1) Hard Wire 3-wire (H N + G)
(1) Screw Terminals
Output Voltage Tolerance +/- 5% static and 100% load step
Output Voltage THD < 2% for 0 to 100% linear load and < 5% for full non linear load
Overload Operation 10 minutes @ 125% and 60 seconds @ 150%
Efficiency at Half Load 95.0%
Required Output Current Protection 75A
Bypass Built-in Maintenance Bypass, Built-in Static Bypass
Input
Nominal Input Voltage 400V 3PH
Input Frequency 40 - 70 Hz (auto sensing)
Input Connections
Hard Wire 5-wire (3PH + N + G)
Input voltage range for main operations 304 - 477V
Input voltage adjustable range for mains operation 340 - 460 (400V)V
Other Input Voltages 380, 415
Maximum Input Current 20A
Input Breaker Capacity 25 A
Input Total Harmonic Distortion Less than 3% for full load
Type of Input Protection Required 3-pole breaker

APC Symmetra PX UPS SY200K250D
APC Symmetra PX UPS SY200K250D
Specifications:GeneralBypass Voltage Tolerance +/-10% settable from +/-4/6/8 and 10%OutputOutput Power Capacity 200 kW / 200 kVAMax Configurable Power 500 kW / 500 kVANominal Output Voltage 400V 3PH, 480V 3PHOutput Voltage Distortion Less than 2%Output Frequency (sync to mains) 50 Hz, 60 HzOther Out
APC Back-UPS BX1100U-LM
APC Back-UPS BX1100U-LM
Back-UPS specification: Output Power Capacity 660 Watts / 1100 VA Max Configurable Power 660 Watts / 1100 VA Nominal Output Voltage 120V Efficiency at Full Load 97.0% Output Frequency (sync to mains) 50/60Hz +/- 3 Hz Topology Line Interactive Waveform Type Stepped approximation to a sinewave
APC Smart-UPS VT SUVTR30KH4B5S
APC Smart-UPS VT SUVTR30KH4B5S
Specifications:OutputOutput Power Capacity 24 kW / 30 kVAMax Configurable Power 24 kW / 30 kVANominal Output Voltage 400V 3PHOutput Voltage Note Configurable for 380 : 400 or 415 V 3 Phase nominal output voltageEfficiency at Full Load 96.4%Output Voltage Distortion Less than 5% at full loadOutput Fr
APC MGE Galaxy 3500 UPS G35TSBP10K30F-DP
APC MGE Galaxy 3500 UPS G35TSBP10K30F-DP
Specifications:OutputNominal Output Voltage 208VInputNominal Input Voltage 208V 3PHInput Frequency 60 HzPhysicalNet Weight 154.55 KGMaximum Height 1487.00 mmMaximum Width 351.00 mmMaximum Depth 837.00 mmShipping Weight 189.00 KGShipping Height 1663.00 mmShipping Width 723.00 mmShipping Depth 1104.00
APC Smart-UPS VT SUVTP20KF2B4S
APC Smart-UPS VT SUVTP20KF2B4S
Specifications:OutputOutput Power Capacity 16 kW / 20 kVAMax Configurable Power 16 kW / 20 kVANominal Output Voltage 120V, 208V, 208V 3PHOutput Voltage Note Configurable for 208 and 220V - 3 PhaseEfficiency at Full Load 93.8%Output Voltage Distortion Less than 5% at full loadOutput Frequency (sync t
APC Smart-UPS VT SUVTP15KF2B4S
APC Smart-UPS VT SUVTP15KF2B4S
Specifications:OutputOutput Power Capacity 12 kW / 15 kVAMax Configurable Power 12 kW / 15 kVANominal Output Voltage 120V, 208V, 208V 3PHOutput Voltage Note Configurable for 208 and 220V - 3 PhaseEfficiency at Full Load 93.0%Output Voltage Distortion Less than 5% at full loadOutput Frequency (sync t
APC Symmetra PX UPS SY400K500DR-PD
APC Symmetra PX UPS SY400K500DR-PD
Specifications:GeneralBypass Voltage Tolerance +/-10% settable from +/-4/6/8 and 10%OutputOutput Power Capacity 400 kW / 400 kVAMax Configurable Power 500 kW / 500 kVANominal Output Voltage 400V 3PH, 480V 3PHOutput Voltage Distortion Less than 2%Output Frequency (sync to mains) 50 Hz, 60 HzOther Out
APC Smart-UPS VT SUVTP15KH2B4S
APC Smart-UPS VT SUVTP15KH2B4S
Specifications:OutputOutput Power Capacity 12 kW / 15 kVAMax Configurable Power 12 kW / 15 kVANominal Output Voltage 400V 3PHOutput Voltage Note Configurable for 380 : 400 or 415 V 3 Phase nominal output voltageEfficiency at Full Load 95.7%Output Voltage Distortion Less than 5% at full loadOutput Fr
APC Symmetra PX UPS SY96K96H-NB
APC Symmetra PX UPS SY96K96H-NB
Specifications:GeneralBypass Connection 5 wire (3PH + N + G)Max Bypass Input Current 250ABypass Protection Device 250AOutputOutput Power Capacity 96 kW / 96 kVAMax Configurable Power 160 kW / 160 kVANominal Output Voltage 230V, 400V 3PHOutput Voltage Note Configurable for 380 : 400 or 415 V 3 Phase
APC Symmetra UPS SYH4K6RMT-TF3
APC Symmetra UPS SYH4K6RMT-TF3
Specifications:OutputOutput Power Capacity 2800 Watts / 4000 VAMax Configurable Power 4200 Watts / 6000 VANominal Output Voltage 120V, 208VOutput Voltage Note Configurable for 208 or 240 nominal output voltageEfficiency at Full Load 85.0%Output Voltage Distortion Less than 5% at full loadOutput Freq