Specifications:
Output
Output Power Capacity 12 kW / 15 kVA
Max Configurable Power 12 kW / 15 kVA
Nominal Output Voltage 400V 3PH
Output Voltage Note Configurable for 380 : 400 or 415 V 3 Phase nominal output voltage
Efficiency at Full Load 95.8%
Output Voltage Distortion Less than 5%
Output Frequency (sync to mains) 47 - 53 Hz for 50 Hz nominal
Other Output Voltages 380, 415
Crest Factor Unlimited
Topology Double Conversion Online
Waveform Type Sine wave
Output Connections
(1) Hard Wire 4-wire (3PH + G)
(1) Hard Wire 5-wire (3PH + N + G)
(1) Screw Terminals
Output Voltage Tolerance +/- 5% static and 100% load step
Output Voltage THD < 2% for 0 to 100% linear load and < 5% for full non linear load
Overload Operation 10 minutes @ 125% and 60 seconds @ 150%
Efficiency at Half Load 95.3%
Required Output Current Protection 25A
Bypass Built-in Maintenance Bypass, Built-in Static Bypass
Input
Nominal Input Voltage 400V 3PH
Input Frequency 40 - 70 Hz (auto sensing)
Input Connections
Hard Wire 5-wire (3PH + N + G)
Input voltage range for main operations 304 - 477V
Input voltage adjustable range for mains operation 340 - 460 (400V)V
Other Input Voltages 380, 415
Maximum Input Current 20A
Input Breaker Capacity 25 A
Input Total Harmonic Distortion Less than 5% for full load
Type of Input Protection Required 3-pole breaker

APC Symmetra UPS SYA12K16RMP
APC Symmetra UPS SYA12K16RMP
Specifications:OutputOutput Power Capacity 9600 Watts / 12 kVAMax Configurable Power 12.8 kW / 16 kVANominal Output Voltage 120V, 208VOutput Voltage Note Configurable for 120/208 or 120/240 output voltageOutput Voltage Distortion Less than 5% at full loadOutput Frequency (sync to mains) 47 - 63 HzOt
APC Galaxy VM UPS GVMSB225KGS
APC Galaxy VM UPS GVMSB225KGS
Specifications:GeneralBypass Connection Built-in Static BypassBypass Voltage Tolerance +/-10% settable from +/-4/6/8 and 10%Max Bypass Input Current 350ABypass Protection Device 400AOutputOutput Power Capacity 202.5 kW / 225 kVAMax Configurable Power 202.5 kW / 225 kVANominal Output Voltage 480V 3PH
APC Smart-UPS VT SUVTP15KH4B4S
APC Smart-UPS VT SUVTP15KH4B4S
Specifications:OutputOutput Power Capacity 12 kW / 15 kVAMax Configurable Power 12 kW / 15 kVANominal Output Voltage 400V 3PHOutput Voltage Note Configurable for 380 : 400 or 415 V 3 Phase nominal output voltageEfficiency at Full Load 95.7%Output Voltage Distortion Less than 5% at full loadOutput Fr
APC Smart-UPS SMC1000-2U
APC Smart-UPS SMC1000-2U
Destribtions:APC Smart-UPS,600 Watts /1000 VA,Input 120V /Output 120V, Interface Port USB, Rack Height 2 UIncludes: CD with software, Documentation CD, Installation guide, Rack Mounting brackets, USB cableStandard Lead Time: Usually Ships within 2 Weeks
 APC Symmetra MW UPS SYMF1600KG
APC Symmetra MW UPS SYMF1600KG
Specifications:OutputOutput Power Capacity 1.6 MW / 1.6 MVAMax Configurable Power 1.6 MW / 1.6 MVANominal Output Voltage 480V 3PHOutput Voltage Distortion Less than 5% at full loadOutput Frequency (sync to mains) 60 Hz - programmable +/- 0.5 / 1 / 2 / 4 / 6 / 8%Crest Factor UnlimitedTopology Delta C
APC Symmetra PX UPS SY400K500D
APC Symmetra PX UPS SY400K500D
Specifications:GeneralBypass Voltage Tolerance +/-10% settable from +/-4/6/8 and 10%OutputOutput Power Capacity 400 kW / 400 kVAMax Configurable Power 500 kW / 500 kVANominal Output Voltage 400V 3PH, 480V 3PHOutput Voltage Distortion Less than 2%Output Frequency (sync to mains) 50 Hz, 60 HzOther Out
APC Smart-UPS SURT10000XLT
APC Smart-UPS SURT10000XLT
Specifications:OutputOutput Power Capacity 8000 Watts / 10 kVAMax Configurable Power 8000 Watts / 10 kVANominal Output Voltage 208VOutput Voltage Note Configurable for 208 or 240 nominal output voltageEfficiency at Full Load 92.0%Output Voltage Distortion Less than 3%Output Frequency (sync to mains)
APC Symmetra PX UPS SY300K500D
APC Symmetra PX UPS SY300K500D
Specifications:GeneralBypass Voltage Tolerance +/-10% settable from +/-4/6/8 and 10%OutputOutput Power Capacity 300 kW / 300 kVAMax Configurable Power 500 kW / 500 kVANominal Output Voltage 400V 3PH, 480V 3PHOutput Voltage Distortion Less than 2%Output Frequency (sync to mains) 50 Hz, 60 HzOther Out
APC Smart-UPS VT SUVTP15KH2B2S
APC Smart-UPS VT SUVTP15KH2B2S
Specifications:OutputOutput Power Capacity 12 kW / 15 kVAMax Configurable Power 12 kW / 15 kVANominal Output Voltage 400V 3PHOutput Voltage Note Configurable for 380 : 400 or 415 V 3 Phase nominal output voltageEfficiency at Full Load 95.7%Output Voltage Distortion Less than 5% at full loadOutput Fr
APC MGE Galaxy 3500 UPS G35T20KH2B2S
APC MGE Galaxy 3500 UPS G35T20KH2B2S