APC Smart-UPS SURT6000XLT

APC Smart-UPS SURT6000XLT
share

Specifications:Output
Output Power Capacity 4200 Watts / 6000 VA
Max Configurable Power 4200 Watts / 6000 VA
Nominal Output Voltage 208V
Output Voltage Note Configurable for 208 or 240 nominal output voltage
Efficiency at Full Load 92.0%
Output Voltage Distortion Less than 3%
Output Frequency (sync to mains) 50/60 Hz +/- 3 Hz user adjustable +/- 0.1
Other Output Voltages 240
Crest Factor 3 : 1
Topology Double Conversion Online
Waveform Type Sine wave
Output Connections
(2) NEMA L6-20R NEMA L6-20R
(2) NEMA L6-30R NEMA L6-30R
Bypass Internal Bypass (Automatic and Manual)
Input
Nominal Input Voltage 208V
Input Frequency 50/60 Hz +/- 5 Hz (auto sensing)
Input Connections
NEMA L6-30P NEMA L6-30P
Cord Length 3.05 meters
Input voltage range for main operations 160 - 280V
Input voltage adjustable range for mains operation 100 - 280V
Other Input Voltages 240

APC Smart-UPS SUA1000XL
APC Smart-UPS SUA1000XL
Specifications:OutputOutput Power Capacity 800 Watts / 1000 VAMax Configurable Power 800 Watts / 1000 VANominal Output Voltage 120VOutput Voltage Distortion Less than 5% at full loadOutput Frequency (sync to mains) 47 - 53 Hz for 50 Hz nominal, 57 - 63 Hz for 60 Hz nominalTopology Line InteractiveWa
APC Smart-UPS SURTD6000RMXLP3U
APC Smart-UPS SURTD6000RMXLP3U
Specifications:OutputOutput Power Capacity 4200 Watts / 6000 VAMax Configurable Power 4200 Watts / 6000 VANominal Output Voltage 120V, 208VOutput Voltage Note Configurable for 208 or 240 nominal output voltageEfficiency at Full Load 90.0%Output Voltage Distortion Less than 2%Output Frequency (sync t
APC Smart-UPS SUA2200
APC Smart-UPS SUA2200
Destribtions:APC Smart-UPS,1980 Watts /2200 VA,Input 120V /Output 120V, Interface Port DB-9 RS-232, SmartSlotIncludes: CD with software, Smart UPS signalling RS-232 cable, USB cable, User ManualStandard Lead Time: Usually in Stock
APC Smart-UPS SMC1000-2U
APC Smart-UPS SMC1000-2U
Destribtions:APC Smart-UPS,600 Watts /1000 VA,Input 120V /Output 120V, Interface Port USB, Rack Height 2 UIncludes: CD with software, Documentation CD, Installation guide, Rack Mounting brackets, USB cableStandard Lead Time: Usually Ships within 2 Weeks
APC MGE Galaxy 3500 UPS G35T10KF4B4S
APC MGE Galaxy 3500 UPS G35T10KF4B4S
Specifications:OutputOutput Power Capacity 8000 Watts / 10 kVAMax Configurable Power 8000 Watts / 10 kVANominal Output Voltage 208V 3PHOutput Voltage Note Configurable for 200 : 208 or 220V 3 Phase nominal output voltageEfficiency at Full Load 93.2%Output Voltage Distortion Less than 3%Output Freque
APC Flywheel UPS FWP78VXESIL
APC Flywheel UPS FWP78VXESIL
Specifications:OutputOutput Power Capacity 300 kW / 300 kVAUser Definable Output Voltages 480V 3PHInputUser Definable Input Voltage 480V 3PHPhysicalMaximum Height 73.70 inches (1872 mm)Maximum Width 30.00 inches (762 mm)Maximum Depth 30.00 inches (762 mm)Net Weight 1822.00 lbs. (828.18 kg)Shipping W
APC Symmetra UPS SYA12K16PXR
APC Symmetra UPS SYA12K16PXR
Specifications:OutputOutput Power Capacity 9600 Watts / 12 kVAMax Configurable Power 12.8 kW / 16 kVANominal Output Voltage 120V, 208VOutput Voltage Note Configurable for 120/208 or 120/240 output voltageOutput Voltage Distortion Less than 5% at full loadOutput Frequency (sync to mains) 47 - 63 HzOt
APC Symmetra UPS SYA16K16RMP
APC Symmetra UPS SYA16K16RMP
Specifications:OutputOutput Power Capacity 12.8 kW / 16 kVAMax Configurable Power 12.8 kW / 16 kVANominal Output Voltage 120V, 208VOutput Voltage Note Configurable for 120/208 or 120/240 output voltageOutput Voltage Distortion Less than 5% at full loadOutput Frequency (sync to mains) 47 - 63 HzOther
APC Galaxy VM UPS GVMPB160KGS
APC Galaxy VM UPS GVMPB160KGS
Specifications:GeneralBypass Connection Built-in Static BypassBypass Voltage Tolerance +/-10% settable from +/-4/6/8 and 10%Max Bypass Input Current 217ABypass Protection Device 400AOutputOutput Power Capacity 144 kW / 160 kVAMax Configurable Power 144 kW / 160 kVANominal Output Voltage 480V 3PHOutp
APC MGE Galaxy 5000 UPS G5TUPS100
APC MGE Galaxy 5000 UPS G5TUPS100
Specifications:GeneralMax Bypass Input Current 169AOutputOutput Power Capacity 90 kW / 100 kVAMax Configurable Power 90 kW / 130 kVANominal Output Voltage 400V 3PH, 480V 3PH, 600V 3PHOutput Voltage Note Configurable for 380 : 400 or 415 V 3 Phase nominal output voltageEfficiency at Full Load 92.9%Ou