Cart()
 
 
Categories
Contact Us
  • A&S Power Supply Co.,Ltd
  • Address:469, Xinsheng Road, Gaoxin District, Chengdu, Sichuan, China
  • Tel:+86-28-65376776
  • Fax:+86-28-86129221
  • Email:inverter@electrical8.com
  • Contact Person:Karina
Home / Products / UPS Power Supply / APC UPS Power Supply / APC Symmetra PX UPS / APC Symmetra PX UPS SY125K250DL-PD

APC Symmetra PX UPS SY125K250DL-PD

APC Symmetra PX UPS SY125K250DL-PD
share

Specifications:General
Bypass Voltage Tolerance +/-10% settable from +/-4/6/8 and 10%
Output
Output Power Capacity 125 kW / 125 kVA
Max Configurable Power 500 kW / 500 kVA
Nominal Output Voltage 400V 3PH, 480V 3PH
Output Voltage Distortion Less than 2%
Output Frequency (sync to mains) 50 Hz, 60 Hz
Other Output Voltages 415
Crest Factor Unlimited
Topology Double Conversion Online
Waveform Type Sine wave
Output Connections
(1) Hard Wire 4-wire (3PH + G)
(1) Hard Wire 5-wire (3PH + N + G)
Output Voltage Tolerance +/-1% static and +/- 5% at 100% load step
Output Voltage THD < 2% linear load and <3% non-linear load
Overload Operation 10 minutes @ 125% and 60 seconds @ 150%
Bypass Built-in Maintenance Bypass, Built-in Static Bypass
Input
Nominal Input Voltage 400V 3PH, 480V 3PH
Input Frequency 40 - 70 Hz (auto sensing)
Input Connections
Hard Wire 4-wire (3PH + G)
Hard Wire 5-wire (3PH + N + G)
Input voltage range for main operations 340 - 460 (400V), 408 - 552 (480)V
Other Input Voltages 415
Maximum Short Circuit Withstand (Icw) 50.0 kA
Input Total Harmonic Distortion Less than 5% for full load
Type of Input Protection Required 3-pole breaker

APC Symmetra PX UPS SY10K40F
APC Symmetra PX UPS SY10K40F
Specifications:GeneralBypass Connection 5 wire 3PH + N +GMax Bypass Input Current 162ABypass Protection Device 175AOutputOutput Power Capacity 10 kW / 10 kVAMax Configurable Power 40 kW / 40 kVANominal Output Voltage 120V, 208V, 208V 3PHOutput Voltage Distortion Less than 5%Output Frequency (sync to
APC Smart-UPS VT SUVTR20KF2B5S
APC Smart-UPS VT SUVTR20KF2B5S
Specifications:OutputOutput Power Capacity 16 kW / 20 kVAMax Configurable Power 16 kW / 20 kVANominal Output Voltage 120V, 208V, 208V 3PHOutput Voltage Note Configurable for 200 : 208 or 220V 3 Phase nominal output voltageOutput Voltage Distortion Less than 5% at full loadOutput Frequency (sync to m
APC Back-UPS BE350G-LM
APC Back-UPS BE350G-LM
Back-UPS specification:Output Frequency (sync to mains) 47 - 63 HzTopology StandbyWaveform Type Stepped approximation to a sinewaveOutput Connections(3) NEMA 5-15R (Battery Backup) NEMA 5-15R(3) NEMA 5-15R (Surge Protection) NEMA 5-15RInputNominal Input Voltage 120VInput Frequency 50/60 Hz +/- 3 Hz
APC MGE EPS 7000 UPS E7TUPS300
APC MGE EPS 7000 UPS E7TUPS300
Specifications:GeneralMax Bypass Input Current 361AOutputOutput Power Capacity 270 kW / 300 kVAMax Configurable Power 270 kW / 300 kVANominal Output Voltage 480V 3PH, 600V 3PHEfficiency at Full Load 93.5%Output Voltage Distortion Less than 2%Output Frequency (sync to mains) 60 HzOther Output Voltage
APC MGE Galaxy 5000 UPS SUG540S90UL
APC MGE Galaxy 5000 UPS SUG540S90UL
Specifications:GeneralBypass Connection 4 wire (3Ph + N) or 5 wire (3Ph + N + G)OutputOutput Power Capacity 36 kW / 40 kVAMax Configurable Power 36 kW / 0 VANominal Output Voltage 480V 3PH, 600V 3PHEfficiency at Full Load 93.3%Output Voltage Distortion Less than 2%Output Frequency (sync to mains) 60
APC Symmetra UPS SYA16K16P
APC Symmetra UPS SYA16K16P
Specifications:OutputOutput Power Capacity 12.8 kW / 16 kVAMax Configurable Power 12.8 kW / 16 kVANominal Output Voltage 120V, 208VOutput Voltage Note Configurable for 120/208 or 120/240 output voltageOutput Voltage Distortion Less than 5% at full loadOutput Frequency (sync to mains) 47 - 63 HzOther
APC Smart-UPS VT SUVTP20KF2B4S
APC Smart-UPS VT SUVTP20KF2B4S
Specifications:OutputOutput Power Capacity 16 kW / 20 kVAMax Configurable Power 16 kW / 20 kVANominal Output Voltage 120V, 208V, 208V 3PHOutput Voltage Note Configurable for 208 and 220V - 3 PhaseEfficiency at Full Load 93.8%Output Voltage Distortion Less than 5% at full loadOutput Frequency (sync t
APC MGE Galaxy 4000 UPS G4TUPS65
APC MGE Galaxy 4000 UPS G4TUPS65
Specifications:GeneralBypass Connection 5 wire (3PH + N + G)Bypass Voltage Tolerance +/- 15%Max Bypass Input Current 180AOutputOutput Power Capacity 52 kW / 65 kVAMax Configurable Power 52 kW / 65 kVANominal Output Voltage 208V 3PHEfficiency at Full Load 87.4%Output Voltage Distortion Less than 3%Ou
APC Smart-UPS VT SUVTP15KF2B2S
APC Smart-UPS VT SUVTP15KF2B2S
Specifications:OutputOutput Power Capacity 12 kW / 15 kVAMax Configurable Power 12 kW / 15 kVANominal Output Voltage 120V, 208V, 208V 3PHOutput Voltage Note Configurable for 208 and 220V - 3 PhaseEfficiency at Full Load 93.0%Output Voltage Distortion Less than 5% at full loadOutput Frequency (sync t
APC Smart-UPS VT SUVTP20KH3B4S
APC Smart-UPS VT SUVTP20KH3B4S
Specifications:OutputOutput Power Capacity 16 kW / 20 kVAMax Configurable Power 16 kW / 20 kVANominal Output Voltage 400V 3PHOutput Voltage Note Configurable for 380 : 400 or 415 V 3 Phase nominal output voltageEfficiency at Full Load 95.3%Output Voltage Distortion Less than 5% at full loadOutput Fr