Specification:
Nominal input voltage / voltage range 230VAC / 161~276VAC
Input frequency range 50/60Hz normal mode / 40-70Hz generator mode
Boost threshold 207VAC ± 4% / 215VAC ± 4% (setup 230VAC wide range)
Output voltage 220, 230, 240VAC
Voltage tolerance (battery mode) ± 5% RMS
THD(i) linear load < 3% THD
(typical) non-linear load < 6% THD
Frequencytolerance synchronization range 45-55Hz / 55-65Hz
battery mode 50/60 ±0.1Hz
Power factor 0.9

EFFEKTA  AC line-interactive ME-Series Uninterruptible Power Supply ME 1000
EFFEKTA AC line-interactive ME-Series Uninterruptible Power Supply ME 1000
Specification:InputNominal voltage 230 VACVoltage range 170-280 VACInput frequency 50/60 HzFrequency range 45-65 HzOutput Output voltage 230 VACFrequency 50/60 Hz ±1% (battery operation)Waveform modifi ed sine wave
EFFEKTA AC line-interactive MTD-RM-Series Uninterruptible Power Supply MTD 1000 RM
EFFEKTA AC line-interactive MTD-RM-Series Uninterruptible Power Supply MTD 1000 RM
Specification:Nominal input voltage 230VACInput voltage range 170~300VACInput frequency range 45~70Hz Auto-SensingBoost starting value / shutt-off 195.5VAC ± 2% / 205.5VAC ± 2%Output voltage Adjustable on LCD Display 220, 230, 240VACVoltage tolerance Line Mode ± 15% Battery Mode
EFFEKTA AC large Uninterruptible Power Supply Pegasus II 125kVA
EFFEKTA AC large Uninterruptible Power Supply Pegasus II 125kVA
Description:Online double-conversion UPS with 3-phase in- and output.. The system can be configured for parallel redundancy. There can be up to 8 units in parallel.The usage of IGBT rectifiers reduces the distortion of dependent mains. The current drain is pure sine wave.
EFFEKTA AC large Uninterruptible Power Supply QUASAR II 20kVA
EFFEKTA AC large Uninterruptible Power Supply QUASAR II 20kVA
Description:UPS-classification VFI-SS-111 in accordance with IEC 62040-3Online double-conversion with sine-wave outputIGBT-rectifierComfortable front control panel incl. EPOInterface for EPO remote controlSpace-saving cable feeding from the bottom of the housingSmall dimensions (all models 910 x 390
EFFEKTA AC line-interactive MID-Series Uninterruptible Power Supply MID 400
EFFEKTA AC line-interactive MID-Series Uninterruptible Power Supply MID 400
Specification:Input Nominal input voltage 230VACInput voltage range 162~290VACInput frequency range 50~60Hz Auto-SensingBoost starting value / shut-off 210.5VAC ± 2% / 213.5VAC ± 2%Buck starting value / shut-off 256.5VAC ± 2% / 250VAC ± 2%Output Output voltage 220, 230, 240VACPower factor 0.6Vol
EFFEKTA AC large Uninterruptible Power Supply TRITON M3 160kVA
EFFEKTA AC large Uninterruptible Power Supply TRITON M3 160kVA
Description:With the TRITON EFFEKTA® offers a modern, modular design, online double-conversion UPS with 3-phase input & output.The system has a modular construction. For simple commissioning, operation and maintenance of all controls, ports and the module are accessible from the front.
EFFEKTA AC large Uninterruptible Power Supply TRITON M1 15kVA
EFFEKTA AC large Uninterruptible Power Supply TRITON M1 15kVA
Description:With the TRITON EFFEKTA® offers a modern, modular design, online double-conversion UPS with 3-phase input & output.The system is operated with a power module from 10 to a maximum of 40kVA. Further up to 4 of these systems can be operated in parallel
EFFEKTA AC large Uninterruptible Power Supply MHD 10kVA 3-1
EFFEKTA AC large Uninterruptible Power Supply MHD 10kVA 3-1
Description:UPS-classification VFI-SS-111 (IEC 62040-3)Online Double-ConversionMultiple Microprocessor design baseDetachable control panel with LCDWide input voltage rangeOptionally parallel designDC start and automatic self-diagnostic functionCapacity of battery unlimited
EFFEKTA AC large Uninterruptible Power Supply TRITON M1 10kVA
EFFEKTA AC large Uninterruptible Power Supply TRITON M1 10kVA
Description:With the TRITON EFFEKTA® offers a modern, modular design, online double-conversion UPS with 3-phase input & output.The system is operated with a power module from 10 to a maximum of 40kVA. Further up to 4 of these systems can be operated in parallel
EFFEKTA MKD-RM-series Uninterruptible Power Supply MHD 1000 RM
EFFEKTA MKD-RM-series Uninterruptible Power Supply MHD 1000 RM
Description:The MKD UPS is a modern, microprocessor controlled online double-conversion UPS. The MKD UPS features electronic bypass and is to be applied with supersensitive and critical applications like servers, workstations, metrological or industrial systems.