Categories
- power supply
- TDK Lambda Power Supply
- Yamaha Power Supply
- Omron Power Supply
- Plus Power Supply
- Bestec Power Supply
- Sorensen Power Supply
- Antec Power Supply
- Meanwell Power Supply
- Weidmuller Power Supply
- Hipro Power Supply
- Sparkle Power Supply
- Lenovo Power Supply
- Zippy Power Supply
- Enermax Power Supply
- Agilent Power Supply
- Phihong Power Supply
- Liteon power supply
- Acble Power Supply
- Instek Power Supply
- Zalman Power Supply
- FSP Power Supply
- Aopen Power Supply
- Spellman Supply
- Delta Supply
- Cosel Supply
- Aj`s Power Source Supply
- Coolmax Supply
- MEAN WELL Power Supply
- SENDON Power Supply
- MGE Power Supply
- UPS Power Supply
- APC UPS Power Supply
- Riello UPS Power Supply
- EATON UPS Power Supply
- SANTAK UPS Power Supply
- Siemens UPS Power Supply
- Powerware UPS Power Supply
- OMRON UPS Power Supply
- Mitsubishi UPS Power Suppply
- DELTA Uninterruptible Power Supply
- EAST UPS Power Supply
- EMERSON UPS Power Supply
- Fuji UPS Power Supply
- EFFEKTA Uninterruptible Power Supply
- Gutor UPS Power Supply
- KELONG UPS Power Supply
- LADIS Uninterruptible Power Supply
- CBC UPS Power Supply
- Phoenix UPS Power Supply
- SVC Uninterruptible Power Supply
- Avaya UPS Power Supply
- NETCCA Uninterruptible Power Supply
- battery
- inverter
- Xantrex inverter
- Samlex inverter
- Schumacher inverter
- KACO inverter
- Wagan inverter
- AIMS inverter
- Victron inverter
- Targus inverter
- Whistler inverter
- Enphase inverter
- Satcon inverter
- Sima inverter
- Kensington inverter
- Exeltech inverter
- Stanley inverter
- ABB inverter
- SMA inverter
- Hyundai inverter
- Mastervolt inverter
- YAMAHA inverter
- Belkin inverter
- Microtek inverter
- Growatt inverter
- TDK inverter
- TOSHIBA inverter
- Su kam inverter
- Omnik inverter
- Ingeteam inverter
- Samil Power inverter
- Sungrow inverter
- Cobra inverter
- Power Bright inverter
- Bestek inverter
Contact Us
- A&S Power Supply Co.,Ltd
- Address:469, Xinsheng Road, Gaoxin District, Chengdu, Sichuan, China
- Tel:+86-28-65376776
- Fax:+86-28-86129221
- Email:inverter@electrical8.com
- Contact Person:Karina
Home / Products / UPS Power Supply / Mitsubishi UPS Power Suppply / Mitsubishi 9700 Series UPS 225KVA/180KW
Mitsubishi 9700 Series UPS 225KVA/180KW
share
SPECIFICATION:
AC INPUT CHARACTERISTICS
Configuration 3 phase, 3 wire
Voltage 208V +10% ~ -15%
Input Power Factor 0.98 Typical
Frequency 60 Hz ±5%
Reflected Current THD 3% max. at 100% load; 5% max. at 50% load
STATIC BYPASS INPUT
Configuration 3 phase, 3 or 4 wire
Voltage 120/208V ±10%
Frequency 60 Hz (±3% Tracking window)
Mitsubishi 7011A Series UPS 8KVA
Description:Design: On-Line Double Conversion with Extra Wide Input Voltage and Frequency WindowPower Rating: 6, 8, 10, 12 kVAVoltage Options: Input: 120/208 or 120/240 VAC Single Phase Output: 120/208 or 120/240 VAC Single Phase
Description:Design: On-Line Double Conversion with Extra Wide Input Voltage and Frequency WindowPower Rating: 6, 8, 10, 12 kVAVoltage Options: Input: 120/208 or 120/240 VAC Single Phase Output: 120/208 or 120/240 VAC Single Phase
Mitsubishi 9800AE Series UPS 375KVA
Description:Design: Double Conversion, On-Line TopologyPower Rating: 100, 150, 225, 300, 375, 500, 750 kVAVoltage Options: Input: 480V; Output: 480/277V or 600/346V
Description:Design: Double Conversion, On-Line TopologyPower Rating: 100, 150, 225, 300, 375, 500, 750 kVAVoltage Options: Input: 480V; Output: 480/277V or 600/346V
Mitsubishi 9800AE Series UPS 100KVA
Description:Design: Double Conversion, On-Line TopologyPower Rating: 100, 150, 225, 300, 375, 500, 750 kVAVoltage Options: Input: 480V; Output: 480/277V or 600/346V
Description:Design: Double Conversion, On-Line TopologyPower Rating: 100, 150, 225, 300, 375, 500, 750 kVAVoltage Options: Input: 480V; Output: 480/277V or 600/346V
Mitsubishi 1100B Series UPS 30KVA
Description:Design: Double Conversion On-Line TopologyPower Ratings: 10, 20, 30, 40, 50, 60, 70, & 80 kVAVoltage Options: Input: 208/120V; Output: 208/120VDesign Features:* Modular Design* 20 kVA and Above Can be Operated as a Capacity System or as N+1Available for All Models* Compact Design: 31.5"W
Description:Design: Double Conversion On-Line TopologyPower Ratings: 10, 20, 30, 40, 50, 60, 70, & 80 kVAVoltage Options: Input: 208/120V; Output: 208/120VDesign Features:* Modular Design* 20 kVA and Above Can be Operated as a Capacity System or as N+1Available for All Models* Compact Design: 31.5"W
Mitsubishi 9900B Series UPS 300KVA
Description:Design: Double Conversion On-Line TopologyPower Ratings: 300kVA/300kWVoltage Options: Input: 480; Output: 480
Description:Design: Double Conversion On-Line TopologyPower Ratings: 300kVA/300kWVoltage Options: Input: 480; Output: 480
Mitsubishi 9800AD Series UPS 100KVA/80KW
Specification:AC Input Rating-15% ~ +15%Power: Rated kVA at 1:1.1 ratio480 VAC (600 VAC usinginput transformer)THD (reflected current):6% typical (100% load) 9% typical (50% load)3-phase, 4-wire, plus ground(Bypass: 4-wire, Rectifier: 3-wire)Frequency: 60Hz (±5%)480Y/277 VAC
Specification:AC Input Rating-15% ~ +15%Power: Rated kVA at 1:1.1 ratio480 VAC (600 VAC usinginput transformer)THD (reflected current):6% typical (100% load) 9% typical (50% load)3-phase, 4-wire, plus ground(Bypass: 4-wire, Rectifier: 3-wire)Frequency: 60Hz (±5%)480Y/277 VAC
Mitsubishi 1100B Series UPS 50KVA
Description:Design: Double Conversion On-Line TopologyPower Ratings: 10, 20, 30, 40, 50, 60, 70, & 80 kVAVoltage Options: Input: 208/120V; Output: 208/120VDesign Features:* Modular Design* 20 kVA and Above Can be Operated as a Capacity System or as N+1Available for All Models* Compact Design: 31.5"W
Description:Design: Double Conversion On-Line TopologyPower Ratings: 10, 20, 30, 40, 50, 60, 70, & 80 kVAVoltage Options: Input: 208/120V; Output: 208/120VDesign Features:* Modular Design* 20 kVA and Above Can be Operated as a Capacity System or as N+1Available for All Models* Compact Design: 31.5"W
Mitsubishi 9800AD Series UPS 750KVA/675KW
Specification:AC Input Rating-15% ~ +15%Power: Rated kVA at 1:1.1 ratio480 VAC (600 VAC usinginput transformer)THD (reflected current):6% typical (100% load) 9% typical (50% load)3-phase, 4-wire, plus ground(Bypass: 4-wire, Rectifier: 3-wire)Frequency: 60Hz (±5%)480Y/277 VAC
Specification:AC Input Rating-15% ~ +15%Power: Rated kVA at 1:1.1 ratio480 VAC (600 VAC usinginput transformer)THD (reflected current):6% typical (100% load) 9% typical (50% load)3-phase, 4-wire, plus ground(Bypass: 4-wire, Rectifier: 3-wire)Frequency: 60Hz (±5%)480Y/277 VAC
Mitsubishi 9800AD Series UPS 375KVA/337KW
Specification:AC Input Rating-15% ~ +15%Power: Rated kVA at 1:1.1 ratio480 VAC (600 VAC usinginput transformer)THD (reflected current):6% typical (100% load) 9% typical (50% load)3-phase, 4-wire, plus ground(Bypass: 4-wire, Rectifier: 3-wire)Frequency: 60Hz (±5%)480Y/277 VAC
Specification:AC Input Rating-15% ~ +15%Power: Rated kVA at 1:1.1 ratio480 VAC (600 VAC usinginput transformer)THD (reflected current):6% typical (100% load) 9% typical (50% load)3-phase, 4-wire, plus ground(Bypass: 4-wire, Rectifier: 3-wire)Frequency: 60Hz (±5%)480Y/277 VAC
Mitsubishi 1100B Series UPS 60KVA
Description:Design: Double Conversion On-Line TopologyPower Ratings: 10, 20, 30, 40, 50, 60, 70, & 80 kVAVoltage Options: Input: 208/120V; Output: 208/120VDesign Features:* Modular Design* 20 kVA and Above Can be Operated as a Capacity System or as N+1Available for All Models* Compact Design: 31.5"W
Description:Design: Double Conversion On-Line TopologyPower Ratings: 10, 20, 30, 40, 50, 60, 70, & 80 kVAVoltage Options: Input: 208/120V; Output: 208/120VDesign Features:* Modular Design* 20 kVA and Above Can be Operated as a Capacity System or as N+1Available for All Models* Compact Design: 31.5"W