Omron Power Supply S8JX Switch Mode Power S8JX-G15005CD

Omron Power Supply S8JX Switch Mode Power S8JX-G15005CD
share

Covered type , Input Switchable between 100 to 120 VAC and 200 to 240 VAC , 150 W , Output 5 V 30 A , DIN Rail mounting type
Power rating 150 W
Efficiency 78% Min.
Rated input voltage 100 to 120 VAC200 to 240 VAC
Allowable-input voltage variable range 85 to 132 VAC170 to 264 VAC
Frequency 50/60 Hz (47 to 450 Hz Single-phase)
Rated input current 3.5 A Max. ï¼ˆAt 100 VAC input)2.1 A Max. ï¼ˆAt 200 VAC input)
Leakage current 0.5 mA Max. (At 100 VAC input)1 mA Max. (At 200 VAC input)
Inrush current 20 A Max. ï¼ˆAt 100 VAC input (For cold start at 25 CEL))40 A Max. ï¼ˆAt 200 VAC input (For cold start at 25 CEL))
Rated output voltage 5 VDC
Output voltage variable range -10 to +15% (With V. ADJ)(If the output voltage adjuster (V. ADJ) is turned, the voltage will increase by more than the allowable voltage range. When adjusting the output voltage, confirm the actual output voltage from the Power Supply and be sure that load is not damaged.)
Ripple 2%(p-p) Max. (Under the rated I/O conditions.)
Static input variation influence 0.4% Max.
Static load variation influence 0.8% Max. (At rated input, 0 to 100% load)
Ambient temperature variation influence 0.05 %/CEL Max. (At rated input/output voltage)
Rated output current 30 A
Start up time 500 ms Max. ï¼ˆUp to 90% of output voltage at rated input and output)
Hold time 20 ms Min. (At rated input voltage: 100 or 200 VAC at 100% load.)
Overload protection 105% to 175% of the rated output currentVoltage drop, Automatic reset
Overvoltage protection Operated at 120 to 140 % of the rated output voltage, Shut-offResetting: Reset the power by turning it back (OFF time: at least 7 min)
Overheat protection No
Maintenance forecast monitor output No
Total run time monitor output No
Undervoltage alarm output No
Power failure alarm output No
Parallel operation No (However, backup operation is possible; external diodes required.)
Series operation Yes (Up to 2 Power Supplies with external diode)
Remote sensing function No
Applicable standard (UL) Standard No.: UL Listed: UL508 (Listing), UL UR: UL60950-1 (Recognition)
Applicable standard (CSA) Standard No.: cUL Listed: CSA C22.2 No.107.1, cUR: CSA C22.2 No.60950-1
Applicable standard (EN) Standard No.: EN50178, EN60950-1
Applicable standard (EC Directive (EMI)) Emission Enclosure: Conforms to EN55011 Group 1 Class AEmission AC mains: Conforms to EN55011 Group 1 Class A and based on FCC Class AEMS: EN61204-3 High severity levels
Applicable standard(VDE) Standard No.: VDE0160, VDE0805 Teil 1 File number:
Applicable standard(Other) Conformed standard 2: Terminal block: Based on DIN EN50274 (VDE0660-514)
Ambient temperature Operating: -10 to 60 CELStorage: -25 to 65 CEL(with no icing or condensation)
Ambient humidity Operating: 25 to 85%Storage: 25 to 90%(With no icing or condensation)
Dielectric strength Between all inputs and all outputs: 3 kVAC for 1 min (Detection current: 20 mA)Between all inputs and PE terminals: 2 kVAC for 1 min (Detection current: 20 mA)Between all outputs and PE terminals: 1 kVAC for 1 min (Detection current: 20 mA)
Insulation resistance Between all outputs and all inputs/ PE terminals: 100 MOhm Min. (at 500 VDC)
Vibration resistance 10 to 55 Hz, 0.375 mm single amplitude in each 3 directions for 2 hours
Shock resistance 150 m/s**2, in each 6 directions 3 times
Output indicator Yes (color: green)
Heat radiation Natural air-cooling
Construction Covered type
Terminal type Screw terminal
Mounting type DIN Rail mounting type

Omron Power Supply S8JX Switch Mode Power S8JX-G10012D
Omron Power Supply S8JX Switch Mode Power S8JX-G10012D
Open-Frame Type , Input 100 to 240 VAC , 100W , Output 12V 8.5A , DIN Rail mounting typePower rating 100 WEfficiency 81% Min.Rated input voltage 100 to 240 VACAllowable-i
Omron Power Supply S8VS Series S8VS-09024S-F
Omron Power Supply S8VS Series S8VS-09024S-F
Standard Model , Input 100 to 240 VAC , 60 W , Output 24 V 2.5 A , Screwless Terminal BlockPower rating 60 WEfficiency 83% TYP. ï¼ˆAt 100 VAC input)85% TYP.&
Omron S8JX Switch Mode Power S8JX-P10005D
Omron S8JX Switch Mode Power S8JX-P10005D
Open-Frame Type , Input 100 to 240 VAC , 100W , Output 5V 20A , DIN Rail mounting typePower rating 100 WEfficiency 78% Min.Rated input voltage 100 to 240 VACAllowable-inp
Omron S8JX Switch Mode Power S8JX-G60024C
Omron S8JX Switch Mode Power S8JX-G60024C
Covered type , Input 100/200 VAC , 100 W , Output 24 V 27 A , Front-mounting type Power rating 600 W Efficiency 80% Min. Rated input voltage 100 to 120 VAC200 to 
Omron Power Supply S8VS Series S8VS-24024B-F
Omron Power Supply S8VS Series S8VS-24024B-F
Total Run Time Monitor , Input 100 to 240 VAC , 240 W , Output 24 V 10 APower rating 240 WEfficiency 85% TYP. ï¼ˆAt 100 VAC input)88% TYP. ï¼ˆAt 200 
Omron Power Supply S82S S82S-7312
Omron Power Supply S82S S82S-7312
Input 12 to 24 VDC , 3 W , Output 12 V 0.25 APower rating 3 WEfficiency 60% Min.Rated input voltage 12 to 24 VDCAllowable-input voltage variable range 10.2 to 27.6 V
Omron Power Supply S8VM Series S8VM-05024P
Omron Power Supply S8VM Series S8VM-05024P
Undervoltage Alarm Type , Covered Type , Bottom Mounting Type , Input 100 to 240 VAC , 50 W , Output 24 V 2.2 A , Alarm Output SourcingPower rating 50 
Omron Power Supply S8VS Series S8VS-01524
Omron Power Supply S8VS Series S8VS-01524
Total Run Time Monitor , Input 100 to 240 VAC , 120 W , Output 24 V 5 APower rating 120 WEfficiency 83% TYP. ï¼ˆAt 100 VAC input)85% TYP. ï¼ˆAt 200 V
Omron Power Supply S8VM Series S8VM-05005
Omron Power Supply S8VM Series S8VM-05005
Standard Type , Open-Frame Type , Bottom Mounting Type , Input 100 to 240 VAC , 50 W , Output 5 V 10 APower rating 50 WEfficiency 80% Min.Rated input voltage 10
Omron S8JX Switch Mode Power S8JX-P05024
Omron S8JX Switch Mode Power S8JX-P05024
Open-Frame Type , Input 100 to 240 VAC , 50W , Output 24V 2.1A , Front-mounting typePower rating 50 WEfficiency 77% Min.Rated input voltage 100 to 240 VACAllowable-input volta