Covered type , Input Switchable between 100 to 120 VAC and 200 to 240 VAC , 150 W , Output 5 V 30 A , DIN Rail mounting type
Power rating 150 W
Efficiency 78% Min.
Rated input voltage 100 to 120 VAC200 to 240 VAC
Allowable-input voltage variable range 85 to 132 VAC170 to 264 VAC
Frequency 50/60 Hz (47 to 450 Hz Single-phase)
Rated input current 3.5 A Max. Ã¯Â¼Ë†At 100 VAC input)2.1 A Max. Ã¯Â¼Ë†At 200 VAC input)
Leakage current 0.5 mA Max. (At 100 VAC input)1 mA Max. (At 200 VAC input)
Inrush current 20 A Max. Ã¯Â¼Ë†At 100 VAC input (For cold start at 25 CEL))40 A Max. Ã¯Â¼Ë†At 200 VAC input (For cold start at 25 CEL))
Rated output voltage 5 VDC
Output voltage variable range -10 to +15% (With V. ADJ)(If the output voltage adjuster (V. ADJ) is turned, the voltage will increase by more than the allowable voltage range. When adjusting the output voltage, confirm the actual output voltage from the Power Supply and be sure that load is not damaged.)
Ripple 2%(p-p) Max. (Under the rated I/O conditions.)
Static input variation influence 0.4% Max.
Static load variation influence 0.8% Max. (At rated input, 0 to 100% load)
Ambient temperature variation influence 0.05 %/CEL Max. (At rated input/output voltage)
Rated output current 30 A
Start up time 500 ms Max. Ã¯Â¼Ë†Up to 90% of output voltage at rated input and output)
Hold time 20 ms Min. (At rated input voltage: 100 or 200 VAC at 100% load.)
Overload protection 105% to 175% of the rated output currentVoltage drop, Automatic reset
Overvoltage protection Operated at 120 to 140 % of the rated output voltage, Shut-offResetting: Reset the power by turning it back (OFF time: at least 7 min)
Overheat protection No
Maintenance forecast monitor output No
Total run time monitor output No
Undervoltage alarm output No
Power failure alarm output No
Parallel operation No (However, backup operation is possible; external diodes required.)
Series operation Yes (Up to 2 Power Supplies with external diode)
Remote sensing function No
Applicable standard (UL) Standard No.: UL Listed: UL508 (Listing), UL UR: UL60950-1 (Recognition)
Applicable standard (CSA) Standard No.: cUL Listed: CSA C22.2 No.107.1, cUR: CSA C22.2 No.60950-1
Applicable standard (EN) Standard No.: EN50178, EN60950-1
Applicable standard (EC Directive (EMI)) Emission Enclosure: Conforms to EN55011 Group 1 Class AEmission AC mains: Conforms to EN55011 Group 1 Class A and based on FCC Class AEMS: EN61204-3 High severity levels
Applicable standard(VDE) Standard No.: VDE0160, VDE0805 Teil 1 File number:
Applicable standard(Other) Conformed standard 2: Terminal block: Based on DIN EN50274 (VDE0660-514)
Ambient temperature Operating: -10 to 60 CELStorage: -25 to 65 CEL(with no icing or condensation)
Ambient humidity Operating: 25 to 85%Storage: 25 to 90%(With no icing or condensation)
Dielectric strength Between all inputs and all outputs: 3 kVAC for 1 min (Detection current: 20 mA)Between all inputs and PE terminals: 2 kVAC for 1 min (Detection current: 20 mA)Between all outputs and PE terminals: 1 kVAC for 1 min (Detection current: 20 mA)
Insulation resistance Between all outputs and all inputs/ PE terminals: 100 MOhm Min. (at 500 VDC)
Vibration resistance 10 to 55 Hz, 0.375 mm single amplitude in each 3 directions for 2 hours
Shock resistance 150 m/s**2, in each 6 directions 3 times
Output indicator Yes (color: green)
Heat radiation Natural air-cooling
Construction Covered type
Terminal type Screw terminal
Mounting type DIN Rail mounting type

Omron Power Supply S8EX Series S8EX-P10005LC
Omron Power Supply S8EX Series S8EX-P10005LC
With chassis and cover , Input 100 to 240 VAC , 100W , Output 5V 20APower rating 100 WEfficiency 81% Min. Ã¯Â¼Ë†At 100 VAC input)84% Min. Ã¯Â¼Ë†At 200 VAC inpu
Omron Power Supply S8EX Series S8EX-N01515LC
Omron Power Supply S8EX Series S8EX-N01515LC
With chassis and cover , Input 100 to 240 VAC , 15W , Output 15V 1APower rating 15 WEfficiency 80% Min. Ã¯Â¼Ë†At 100 VAC input)78% Min. Ã¯Â¼Ë†At 200 VAC inputÃ
Omron Power Supply S8JX Switch Mode Power S8JX-P30048CD
Omron Power Supply S8JX Switch Mode Power S8JX-P30048CD
Covered type , Input 100 to 240 VAC , 300W , Output 48V 7A , DIN Rail mounting typePower rating 300 WEfficiency 78% Min.Rated input voltage 100 to 240 VACAllowable-input&
Omron S8JX Switch Mode Power S8JX-G01512C
Omron S8JX Switch Mode Power S8JX-G01512C
Covered type , Input 100 to 240 VAC , 15 W , Output 12 V 1.3 A , Front-mounting typeAs of November 15, 2012Power rating 15 WEfficiency 68% Min.Rated input volta
Omron Power Supply S8VS Series S8VS-12024A
Omron Power Supply S8VS Series S8VS-12024A
Total Run Time Monitor , Input 100 to 240 VAC , 60 W , Output 24 V 2.5 APower rating 60 WEfficiency 83% TYP. Ã¯Â¼Ë†At 100 VAC input)85% TYP. Ã¯Â¼Ë†At 200 V
Omron Power Supply S8EX Series S8EX-BP15024L
Omron Power Supply S8EX Series S8EX-BP15024L
With chassis , Input 100 to 240 VAC , 150W , Output 24V 6.3APower rating 150 WEfficiency 84% Min. Ã¯Â¼Ë†At 100 VAC input)87% Min. Ã¯Â¼Ë†At 200 VAC input)Rated 
Omron Power Supply S8VS Series S8VS-09024BE
Omron Power Supply S8VS Series S8VS-09024BE
Total Run Time Monitor , Input 100 to 240 VAC , 90 W , Output 24 V 3.75 APower rating 90 WEfficiency 83% TYP. Ã¯Â¼Ë†At 100 VAC input)85% TYP. Ã¯Â¼Ë†At 200 
Omron S8JX Switch Mode Power S8JX-P10005D
Omron S8JX Switch Mode Power S8JX-P10005D
Open-Frame Type , Input 100 to 240 VAC , 100W , Output 5V 20A , DIN Rail mounting typePower rating 100 WEfficiency 78% Min.Rated input voltage 100 to 240 VACAllowable-inp
Omron Power Supply S8VS Series S8VS-24024B
Omron Power Supply S8VS Series S8VS-24024B
Total Run Time Monitor , Input 100 to 240 VAC , 240 W , Output 24 V 10 APower rating 240 WEfficiency 85% TYP. Ã¯Â¼Ë†At 100 VAC input)88% TYP. Ã¯Â¼Ë†At 200 
Omron Power Supply S8EX Series S8EX-BP15048L
Omron Power Supply S8EX Series S8EX-BP15048L
With chassis , Input 100 to 240 VAC , 150W , Output 48V 3.2APower rating 150 WEfficiency 85% Min. Ã¯Â¼Ë†At 100 VAC input)88% Min. Ã¯Â¼Ë†At 200 VAC input)Rated