Covered type , Input 100 to 240 VAC , 15 W , Output 5 V 3 A , DIN Rail mounting type
Power rating 15 W
Efficiency 68% Min.
Rated input voltage 100 to 240 VAC
Allowable-input voltage variable range 85 to 264 VAC80 to 370 VDC
Note at DC input The range for compliance with EC Directives and safety standards (UL, EN, etc.) is 100 to 240 VAC (85 to 264 VAC).
Frequency 50/60 Hz (47 to 450 Hz Single-phase)
Rated input current 0.4 A Max. ï¼ˆAt 100 VAC input)0.25 A Max. ï¼ˆAt 200 VAC input)
Leakage current 0.5 mA Max. (At 100 VAC input)1 mA Max. (At 200 VAC input)
Inrush current 20 A Max. ï¼ˆAt 100 VAC input (For cold start at 25 CEL))40 A Max. ï¼ˆAt 200 VAC input (For cold start at 25 CEL))
Rated output voltage 5 VDC
Output voltage variable range -10 to +15% (With V. ADJ)(If the output voltage adjuster (V. ADJ) is turned, the voltage will increase by more than the allowable voltage range. When adjusting the output voltage, confirm the actual output voltage from the Power Supply and be sure that load is not damaged.)
Ripple 2%(p-p) Max. (Under the rated I/O conditions.)
Static input variation influence 0.4% Max. (with AC input voltage)
Static load variation influence 0.8% Max. (At rated input, 0 to 100% load)
Ambient temperature variation influence 0.05 %/CEL Max. (At rated input/output voltage)
Rated output current 3 A
Start up time 500 ms Max. ï¼ˆUp to 90% of output voltage at rated input and output)
Hold time 20 ms Min. (At rated input voltage: 100 or 200 VAC at 100% load.)
Overload protection 105% to 175% of the rated output currentVoltage drop, Intermittent operation, Automatic reset
Overvoltage protection Operated at 120 to 140 % of the rated output voltage, Shut-offResetting: Reset the power by turning it back (OFF time: at least 7 min)
Overheat protection No
Maintenance forecast monitor output No
Total run time monitor output No
Undervoltage alarm output No
Power failure alarm output No
Parallel operation No (However, backup operation is possible; external diodes required.)
Series operation Yes (Up to 2 Power Supplies with external diode)
Remote sensing function No
Applicable standard (UL) Standard No.: UL Listed: UL508 (Listing), UL UR: UL60950-1 (Recognition)
Applicable standard (CSA) Standard No.: cUL Listed: CSA C22.2 No.107.1, cUR: CSA C22.2 No.60950-1
Applicable standard (EN) Standard No.: EN50178, EN60950-1
Applicable standard (EC Directive (EMI)) Emission Enclosure: Conforms to EN55011 Group 1 Class AEmission AC mains: Conforms to EN55011 Group 1 Class A and based on FCC Class AEMS: EN61204-3 High severity levels
Applicable standard(VDE) Standard No.: VDE0160, VDE0805 Teil 1 File number:
Applicable standard(SEMI) F47-0200 (200 VAC input)
Applicable standard(Other) Conformed standard 2: Terminal block: Based on DIN EN50274 (VDE0660-514)
Ambient temperature Operating: -10 to 60 CELStorage: -25 to 65 CEL(with no icing or condensation)
Ambient humidity Operating: 25 to 85%Storage: 25 to 90%(With no icing or condensation)
Dielectric strength Between all inputs and all outputs: 3 kVAC for 1 min (Detection current: 20 mA)Between all inputs and PE terminals: 2 kVAC for 1 min (Detection current: 20 mA)Between all outputs and PE terminals: 1 kVAC for 1 min (Detection current: 20 mA)
Insulation resistance Between all outputs and all inputs/ PE terminals: 100 MOhm Min. (at 500 VDC)
Vibration resistance 10 to 55 Hz, 0.375 mm single amplitude in each 3 directions for 2 hours
Shock resistance 150 m/s**2, in each 6 directions 3 times
Output indicator Yes (color: green)
Heat radiation Natural air-cooling
Construction Covered type
Terminal type Screw terminal
Mounting type DIN Rail mounting type
Weight 370 g Max.

Omron Power Supply S8VS Series S8VS-01524
Omron Power Supply S8VS Series S8VS-01524
Total Run Time Monitor , Input 100 to 240 VAC , 120 W , Output 24 V 5 APower rating 120 WEfficiency 83% TYP. ï¼ˆAt 100 VAC input)85% TYP. ï¼ˆAt 200 V
Omron Power Supply S8JX Switch Mode Power S8JX-G10012D
Omron Power Supply S8JX Switch Mode Power S8JX-G10012D
Open-Frame Type , Input 100 to 240 VAC , 100W , Output 12V 8.5A , DIN Rail mounting typePower rating 100 WEfficiency 81% Min.Rated input voltage 100 to 240 VACAllowable-i
Omron S8JX Switch Mode Power S8JX-G03505D
Omron S8JX Switch Mode Power S8JX-G03505D
Open-Frame Type , Input 100 to 240 VAC , 35W , Output 5V 7A , DIN Rail mounting typeAs of November 15, 2012Power rating 35 WEfficiency 73% Min.Rated input voltage 10
Omron Power Supply S8VS Series S8VS-12024BP
Omron Power Supply S8VS Series S8VS-12024BP
Standard Model , Input 100 to 240 VAC , 15 W , Output 12 V 1.2 APower rating 15 WEfficiency 79% TYP. ï¼ˆAt 100 VAC input)78% TYP. ï¼ˆAt 200 VAC input)Rate
Omron Power Supply S8VM Series S8VM-05012D
Omron Power Supply S8VM Series S8VM-05012D
Standard Type , Open-Frame Type , DIN Rail Mounting Bracket Type , Input 100 to 240 VAC , 50 W , Output 12 V 4.3 APower rating 50 WEfficiency 79% Min.Rated 
Omron Power Supply S8VM Series S8VM-01524A
Omron Power Supply S8VM Series S8VM-01524A
Undervoltage Alarm Type , Covered Type , Bottom Mounting Type , Input 100 to 240 VAC , 15 W , Output 24 V 0.65 APower rating 15 WEfficiency 80% Min.Rated input&
Omron Power Supply S8VS Series S8VS-09024B
Omron Power Supply S8VS Series S8VS-09024B
Total Run Time Monitor , Input 100 to 240 VAC , 90 W , Output 24 V 3.75 APower rating 90 WEfficiency 83% TYP. ï¼ˆAt 100 VAC input)85% TYP. ï¼ˆAt 200 
Omron Power Supply S8VS Series S8VS-24024BE-F
Omron Power Supply S8VS Series S8VS-24024BE-F
TotalPower rating 240 WEfficiency 85% TYP. ï¼ˆAt 100 VAC input)88% TYP. ï¼ˆAt 200 VAC input)Rated input voltage 100 to 240 VACAllowable-input voltage variable range 85 to 264 VAC8
Omron S8JX Switch Mode Power S8JX-G15048C
Omron S8JX Switch Mode Power S8JX-G15048C
Covered type , Input 100 to 240 VAC , 150 W , Output 48 V 3.3 A , Front-mounting type Power rating 150 W Efficiency 85% Min. Rated input voltage 100 to 240 VAC A
Omron Power Supply S8VM Series S8VM-01515
Omron Power Supply S8VM Series S8VM-01515
Standard Type , Open-Frame Type , Bottom Mounting Type , Input 100 to 240 VAC , 15 W , Output 15 V 1 APower rating 15 WEfficiency 78% Min.Rated input voltage 10