Specifications:
INPUT
Rated power 2200 VA
Voltage 220-230-240 Vac
Voltage tolerance 140 Vac < Vin < 276 Vac @50% LOAD / 184 Vac < Vin < 276 Vac @ 100% LOAD
Frequency 50/60 Hz
Frequency tolerance 50 Hz ± 5% / 60 Hz ± 5%
Power factor > 0.99
Current distorsion ≤7%
BY PASS
Voltage tolerance 180 - 264
Frequency tolerance Frequency selected (from ±0.Hz to ±5Hz configurable)
Number phases 1
OUTPUT and INVERTER OUTPUT
Rated power 2200 VA
Active power 1760 W
Number phases 1
Crest factor (Ipeak/Irms) 3 : 1
Waveform Sinewave
Frequency Can be selected: 50 Hz or 60 Hz or self-learning
Voltage distortion with distorcing load < 4%
Voltage distortion with linear load < 2%

Riello Master HP UPS MHT 100
Riello Master HP UPS MHT 100
SpecificationsINPUTRated power 100000 VAVoltage 400 Vac three-phase VacVoltage tolerance + 20% - 25%Frequency 50/60 Hz with autorangeFrequency tolerance 45/65 HzPower factor 0,99Input current 141 ACurrent distorsion
Riello iDialog UPS IDG 600
Riello iDialog UPS IDG 600
Specifications:INPUTRated power 600 VAVoltage 220-240 VacVoltage tolerance 230 Vac (+ 20 / - 25%)Frequency 50/60 Hz auto sensingOUTPUT and INVERTER OUTPUTRated power 600 VAActive power 360 WNumber phases 1Wave form on battery Pseudo sinewaveFrequency on battery operation 50 or 60 Hz (± 1%)
Rielloi Dialog Rack UPS IDR 600
Rielloi Dialog Rack UPS IDR 600
Specifications:INPUTRated power 600 VAVoltage 220-240 VacVoltage tolerance 230 Vac (+ 20 / - 25%)Frequency 50/60 Hz auto sensingOUTPUT and INVERTER OUTPUTRated power 600 VAActive power 360 WNumber phases 1Wave form on battery Pseudo sinewaveFrequency on battery operation 50 or 60 Hz (± 1%)BATTERIES
Riello Master MPS UPS MPT 800
Riello Master MPS UPS MPT 800
Specifications: INPUT Voltage 380 - 400 - 415 Vac three-phase Vac Frequency 45 - 65 Hz Frequency tolerance ± 2% (selectable from ± 1% to ± 5% from front panel) Soft start 0 - 100% in 120’’ (selectable) Voltage Range 400 V + 20% /- 25% BY PASS Rated voltage 380 - 400 - 415 Vac three-ph
Riello Multi Sentry UPS MCM 12
Riello Multi Sentry UPS MCM 12
Specifications:INPUTRated power 12000 VAVoltage 230 Vac single-phase or 400 Vac three-phase + N VacVoltage tolerance ± 20%Frequency tolerance 40/72 HzPower factor 0.99BY PASSRated voltage 230Voltage tolerance ± 15% (selectable from ± 5% to ± 25%)Rated frequency 50/60 HzFrequency tolerance ± 5%
Riello Multi Sentry UPS MST 100
Riello Multi Sentry UPS MST 100
Specifications:INPUTRated power 100000 VAVoltage 400 Vac three-phase + N VacVoltage tolerance ± 20%Frequency tolerance 40/72 HzPower factor 0.99BY PASSRated voltage 400Voltage tolerance ± 15% (selectable from ± 5% to ± 25%)Rated frequency 50/60 HzFrequency tolerance ± 5% (selectable from ± 0.2
Riello Master HP UPS MHT 300
Riello Master HP UPS MHT 300
SpecificationsINPUTRated power 300000 VAVoltage 400 Vac three-phase VacVoltage tolerance + 20% - 25%Frequency 50/60 Hz with autorangeFrequency tolerance 45/65 HzPower factor 0,99Input current 423 ACurrent distorsion
Riello Master MPS UPS MPT 200
Riello Master MPS UPS MPT 200
Specifications:NPUTVoltage 380 - 400 - 415 Vac three-phase VacFrequency 45 - 65 HzFrequency tolerance ± 2% (selectable from ± 1% to ± 5% from front panel)Soft start 0 - 100% in 120’’ (selectable)Voltage Range 400 V + 20% /- 25%BY PASSRated voltage 380 - 400 - 415 Vac three-phase + NRated freq
Riello Master HP UL UPS MHT UL 65
Riello Master HP UL UPS MHT UL 65
Specifications: INPUT Voltage 480 Vac tolerance + N Vac Frequency 45 ÷ 65 Hz Power factor > 0,99 Current distorsion <3% Soft start 0 ÷ 100% in 30" OUTPUT Rated power 65000 VA Active power 58500 W
Riello Vision Dual UPS VSD 2200
Riello Vision Dual UPS VSD 2200
Specifications: INPUT Rated power 2200 VA Voltage 220-230-240 Vac Frequency 50/60 Hz with automatic selection Frequency tolerance ± 5Hz Power factor > 0,98 Current distorsion < 7% OUTPUT and INVERTER OUTPUT Rated power 2200 VA Active power 1980 W Number phases 1 Crest factor (Ipea