Specifications:
INPUT
Rated power 800 VA
Voltage 220-240 Vac
Voltage tolerance 230 Vac (+ 20 / - 25%)
Frequency 50/60 Hz with auto sensing
OUTPUT and INVERTER OUTPUT
Rated power 800 VA
Active power 480 W
Number phases 1
Wave form on battery Pseudo sinewave
Frequency on battery operation 50 or 60 Hz (+/- 1%)
BATTERIES
Type VRLA AGM Maintenance-free lead-acid
Typical recharge time 6-8 h
ENVIRONMENTAL
Altitude max 6000
Color Black
Communication USB
Safety compliance EN 62040-1-1 and Directive 2006/95/EC; EN 62040-3
EMC conformance EN 62040-2 and Directive 2004/108 EC
Accessories provided user guide
Protection rating 1
Marks CE; GS/TUV on Schuko version
Operating temperature 0 ÷ 40 °C
Relative humidity <95% non condensing
Output sockets 5+3
DATA
Weight 4,1 Kg
Dimensions (h w d) 99x175x313 mm

Riello Master MPS UPS MPT 200
Riello Master MPS UPS MPT 200
Specifications:NPUTVoltage 380 - 400 - 415 Vac three-phase VacFrequency 45 - 65 HzFrequency tolerance ± 2% (selectable from ± 1% to ± 5% from front panel)Soft start 0 - 100% in 120’’ (selectable)Voltage Range 400 V + 20% /- 25%BY PASSRated voltage 380 - 400 - 415 Vac three-phase + NRated freq
Riello Master HP UL UPS MHT UL 160
Riello Master HP UL UPS MHT UL 160
Specifications: Input voltage and frequency 480 VAC Three phase - 45~65 Hz ±2% selectable from ±1% to ±5% from front panel Output voltage ans frequency 380, 400, 415 VAC Three phase - 50/60 Hz (selactable Waveform Sinusoidal Power(KVA/KW)160/144 %Input voltage distoration (THDi) <3 Outpu
Riello iPlug UPS IPG 600
Riello iPlug UPS IPG 600
Specifications:INPUTRated power 600 VAVoltage 220-240 VacVoltage tolerance 230 Vac (+ 20 / - 25%)Frequency 50/60 Hz with auto sensingOUTPUT and INVERTER OUTPUTRated power 600 VAActive power 360 WNumber phases 1Wave form on battery Pseudo sinewaveFrequency on battery operation 50 or 60 Hz (+/- 1%)
Riello iDialog UPS IDG 400
Riello iDialog UPS IDG 400
Specifications:INPUTRated power 400 VAVoltage 220-240 VacVoltage tolerance 230 Vac (+ 20 / - 25%)Frequency 50/60 Hz auto sensingOUTPUT and INVERTER OUTPUTRated power 400 VAActive power 240 WNumber phases 1Wave form on battery Pseudo sinewaveFrequency on battery operation 50 or 60 Hz (± 1%)BATTERIES
Riello Multi Sentry UPS MST 80
Riello Multi Sentry UPS MST 80
Specifications:INPUTINPUTRated power 80000 VAVoltage 400 Vac three-phase + N VacVoltage tolerance ± 20%Frequency tolerance 40/72 HzPower factor 0.99BY PASSRated voltage 400Voltage tolerance ± 15% (selectable from ± 5% to ± 25%)Rated frequency 50/60 HzFrequency tolerance ± 5% (selectable from ±
Riello Vision Dual UPS VSD 3000
Riello Vision Dual UPS VSD 3000
Specifications: INPUT Rated power 3000 VA Voltage 220-230-240 Vac Frequency 50/60 Hz with automatic selection Frequency tolerance ± 5Hz Power factor > 0,98 Current distorsion < 7% OUTPUT and INVERTER OUTPUT Rated power 3000 VA Active power 2700 W Number phases 1 Crest factor (Ipea
Riello Master HP UPS MHT 300
Riello Master HP UPS MHT 300
SpecificationsINPUTRated power 300000 VAVoltage 400 Vac three-phase VacVoltage tolerance + 20% - 25%Frequency 50/60 Hz with autorangeFrequency tolerance 45/65 HzPower factor 0,99Input current 423 ACurrent distorsion
Riello Multi Sentry UPS MCT 10
Riello Multi Sentry UPS MCT 10
Specifications:INPUTRated power 10000 VAVoltage 400 Vac three-phase + N VacVoltage tolerance ± 20%Frequency tolerance 40/72 HzPower factor 0.99BY PASSRated voltage 400Voltage tolerance ± 15% (selectable from ± 5% to ± 25%)Rated frequency 50/60 HzFrequency tolerance ± 5% (selectable from ± 0.25
Riello Master HE UPS MHE 400
Riello Master HE UPS MHE 400
Specifications: INPUT Rated power 400000 VA Voltage 400 Vac three-phase Vac Voltage tolerance + 20% - 25% Frequency 50/60 Hz with autorange Frequency tolerance 45/65 Hz Power factor 0,99 Input current 564 A Current distorsion <3% Soft start 0-100% in 10 BY PASS Rated voltage 400 Vac t
Riello Sentinel Dual (High Power) UPS SDL 4000
Riello Sentinel Dual (High Power) UPS SDL 4000
Specifications:INPUTRated power 4000 VAVoltage 220-230-240 VacFrequency 50/60 Hz ± 5 HzPower factor >0.98Current distorsion ≤7%BY PASSVoltage tolerance 180÷264 Vac (selectable in Economy Mode and SMART ACTIVE Mode)Frequency tolerance Selected frequency ± 5% (user configurable)OUTPUT and INVERTE