For even more power per surface area: up to two high-performance Sunny Central HE-20 are part of a medium-voltage station (MV) that feeds directly into a shared medium-voltage transformer. This transforms two Sunny Central 800HE inverters, for example, into one Sunny Central 1600MV station. A peak efficiency of more than 98 percent is achieved using an amorphous transformer. The new MV station integrates highperformance communications components and also requires even less maintenance. Moreover, the new MV station offers extensive grid management functions and fulfills all of the requirements of the medium-voltage directive.
Powerful
Peak output of up to 1,760 kVA
Turnkey solution for direct connection to the medium-voltage grid
High yields plus reliability
Max. yields thanks to an optimized AC power path
Comprehensive grid management functions including complete dynamic grid support (BDEW compliant)
Communicative
High-performance industrial PC with a range of integrated interfaces
Open communication interfaces, for example, Modbus, OPC
Flexible
Medium-voltage switchgear systems for flexibly designing large PV farms
Amorphous transformer for minimal open-circuit losses
Use in a chemically aggressive environment
Input (DC)
Max. DC power (@ cos Ï† = 1) 1120 kW
Max. input voltage 1) 1000 V / 1100 V optional
MPP voltage range (@ 25°C / @ 40°C at 50 Hz) 2) 449 V â€“ 820 V / 430 V â€“ 820 V
Rated input voltage 480 V
Max. input current 2500 A
Min. input voltage / VMPP_min at IMPP < IDCmax 429 V / 430 V
Number of independent MPP inputs 2
Number of DC inputs 18 inputs equipped with fuses
-Output (AC)
Rated power (@ 25 °C) / nominal AC power (@ 40 °C) 1100 kVA / 1000 kVA
Nominal AC voltage / range 20000 V / 18000 V â€“ 22000 V
AC power frequency / range 50 Hz / 47 Hz ... 53 Hz
Rated power frequency / rated grid voltage 50 Hz / 20000 V
Max. output current 31.8 A
Max. total harmonic factor < 3 %
Power factor at rated power / displacement power factor adjustable 3) 1 / 0.9 overexcited ... 0.9 underexcited
Feed-in phases / connection phases 3 / 3
-Efficiency 4)
Max. efficiency 98 % (98.2 %) 5)
European weighted efficiency / CEC efficiency 97.5 % (97.8 %)5)
-Protective devices
DC disconnect device Motor-driven DC switch-disconnector
AC disconnect device Optionally (switch-disconnector with HH fuses)
DC overvoltage protection / AC overvoltage protection on the LV side Surge arrester type I / surge arrester type II
Grid monitoring / plant monitoring yes / Optionally (via Sunny Portal)
Ground-fault monitoring / remote-controlled ground-fault monitoring opt. / opt.
Insulation monitoring opt.
Galvanic isolation yes
Protection class (according to IEC 62103)3) / electric arc resistance (according to IEC 62271-202) I / IAC AB 20 kA 1s
-General data
Dimensions (W / H / D) 5400 / 3605 / 3000 mm(212.6 / 141.9 / 118.1 inch)
Weight 33245 kg / 73293 lb
Operating temperature range -20 °C ... +40 °C /-4 °F ... +104 °F
Noise emission < 65 dB(A)
Max. self-consumption (operation) / self-consumption (night) 3000 W 3) / < 180 W + 1100 W6)
External auxiliary supply voltage / external back-up fuse for auxiliary power supply 230 / 400 V (3 / N / PE) / B 32 A, 3-pin
Cooling principle (inverter / transformer) Forced cooling / natural convection
Degree of protection (according to IEC 60529) 7) IP23D
Application In unprotected outdoor environments
Use in a chemically aggressive environment opt.
Max. permissible value for relative humidity (non-condensing) 15 % ... 95 %
Max. operating altitude above MSL 1000 m
Fresh-air consumption (inverter) 6000 m³/h
-Features
DC connection Ring terminal lug
AC connection, MV side External taper angle plug
Display 3) HMI touchscreen
Communication protocols / Sunny String-Monitor Ethernet, Modbus / RS485 / none (Optiprotect)
SC-COM/Communit yes / opt.
Transformer for auxiliary power supply opt.
Medium-voltage transformer with amorphous core opt.
Medium-voltage switchgear opt.
Color enclosure / door / base / roof RAL 7035 / 7024 / 7024 / 7024
Certificates and approvals (more available on request) EN 61000-6-2, EN 61000-6-4, IEC 62271-202, EMC compliant, CE compliant, Arrêté du 23/04/08, R.D. 1663 / 2000, R.D. 661 / 2007, BDEW-MSRL / FGW / TR8 8)

SMA Wind Energy Inverters WINDY BOY 4000TLRP
SMA Wind Energy Inverters WINDY BOY 4000TLRP
One for all: the new transformerless Windy Boy is the perfect solution for horizontal and vertical axis small wind turbine systems. The two additional power classes provi
SMA Wind Energy Inverters WINDY BOY 3300
SMA Wind Energy Inverters WINDY BOY 3300
With a maximum efficiency of 95.6 percent, the Windy Boy 3300 and 3800 inverters are among the most cost-effective for small wind turbine systems. The weatherproof enclos
SMA Wind Energy Inverters WINDY BOY 1700
SMA Wind Energy Inverters WINDY BOY 1700
Ideal for small wind turbine systems: The programmable polynomial curve of the Windy Boy 1200 and 1700 inverters allows optimal adjustment to the turbine characteristic curve&
SMA Wind Energy Inverters WINDY BOY 5000TL
SMA Wind Energy Inverters WINDY BOY 5000TL
With even better communication, usability and efficiency, the Windy Boy 3600TL and 5000 TL inverters set new standards. With a modern graphic display, a simplified mounting&nb
SMA Wind Energy Inverters WINDY BOY 3600TLRP
SMA Wind Energy Inverters WINDY BOY 3600TLRP
One for all: the new transformerless Windy Boy is the perfect solution for horizontal and vertical axis small wind turbine systems. The two additional power classes provi
SMA Wind Energy Inverters WINDY BOY Protection Box 600
SMA Wind Energy Inverters WINDY BOY Protection Box 600
The Windy Boy Protection Box can do it all: It protects the inverter from excess voltage by feeding excess generator voltage to a load resistance, which slows down&n
SMA Battery Inverters SUNNY ISLAND 5048
SMA Battery Inverters SUNNY ISLAND 5048
Commissioning just takes a few minutes: For Sunny Island 5048, the settings needed for operation can be configured in very few steps. It is flexible in its applicati
SMA Wind Energy Inverters WINDY BOY Protection Box 400
SMA Wind Energy Inverters WINDY BOY Protection Box 400
The Windy Boy Protection Box can do it all: It protects the inverter from excess voltage by feeding excess generator voltage to a load resistance, which slows down&n
SMA Battery Inverters SUNNY ISLAND 8.0H
SMA Battery Inverters SUNNY ISLAND 8.0H
The new OptiUse operating concept makes installation, commissioning and day-to-day use easier than ever before. The Quick Configuration Guide helps you complete the commissioning i
SMA Central Inverters TRANSFORMER COMPACT STATION 800SC
SMA Central Inverters TRANSFORMER COMPACT STATION 800SC
The Transformer Compact Station â€“ now also for 900 kVA nominal power â€“ is the ideal link between SMA central inverters and the medium-voltage grid. As a&nbs