- power supply
- TDK Lambda Power Supply
- Yamaha Power Supply
- Omron Power Supply
- Plus Power Supply
- Bestec Power Supply
- Sorensen Power Supply
- Antec Power Supply
- Meanwell Power Supply
- Weidmuller Power Supply
- Hipro Power Supply
- Sparkle Power Supply
- Lenovo Power Supply
- Zippy Power Supply
- Enermax Power Supply
- Agilent Power Supply
- Phihong Power Supply
- Liteon power supply
- Acble Power Supply
- Instek Power Supply
- Zalman Power Supply
- FSP Power Supply
- Aopen Power Supply
- Spellman Supply
- Delta Supply
- Cosel Supply
- Aj`s Power Source Supply
- Coolmax Supply
- MEAN WELL Power Supply
- SENDON Power Supply
- MGE Power Supply
- UPS Power Supply
- APC UPS Power Supply
- Riello UPS Power Supply
- EATON UPS Power Supply
- SANTAK UPS Power Supply
- Siemens UPS Power Supply
- Powerware UPS Power Supply
- OMRON UPS Power Supply
- Mitsubishi UPS Power Suppply
- DELTA Uninterruptible Power Supply
- EAST UPS Power Supply
- EMERSON UPS Power Supply
- Fuji UPS Power Supply
- EFFEKTA Uninterruptible Power Supply
- Gutor UPS Power Supply
- KELONG UPS Power Supply
- LADIS Uninterruptible Power Supply
- CBC UPS Power Supply
- Phoenix UPS Power Supply
- SVC Uninterruptible Power Supply
- Avaya UPS Power Supply
- NETCCA Uninterruptible Power Supply
- battery
- inverter
- Xantrex inverter
- Samlex inverter
- Schumacher inverter
- KACO inverter
- Wagan inverter
- AIMS inverter
- Victron inverter
- Targus inverter
- Whistler inverter
- Enphase inverter
- Satcon inverter
- Sima inverter
- Kensington inverter
- Exeltech inverter
- Stanley inverter
- ABB inverter
- SMA inverter
- Hyundai inverter
- Mastervolt inverter
- YAMAHA inverter
- Belkin inverter
- Microtek inverter
- Growatt inverter
- TDK inverter
- TOSHIBA inverter
- Su kam inverter
- Omnik inverter
- Ingeteam inverter
- Samil Power inverter
- Sungrow inverter
- Cobra inverter
- Power Bright inverter
- Bestek inverter
- A&S Power Supply Co.,Ltd
- Address:469, Xinsheng Road, Gaoxin District, Chengdu, Sichuan, China
- Tel:+86-28-65376776
- Fax:+86-28-86129221
- Email:inverter@electrical8.com
- Contact Person:Karina
APC Smart-UPS VT SUVTR20KG5B5S

Specifications:
Output
Output Power Capacity 16 kW / 20 kVA
Max Configurable Power 16 kW / 20 kVA
Nominal Output Voltage 120V, 208V, 208V 3PH
Output Voltage Note Configurable for 200 : 208 or 220V 3 Phase nominal output voltage
Efficiency at Full Load 93.8%
Output Voltage Distortion Less than 5% at full load
Output Frequency (sync to mains) 57 - 63 Hz for 60 Hz nominal
Crest Factor Unlimited
Topology Double Conversion Online
Waveform Type Sine wave
Output Connections
(1) Hard Wire 5-wire (3PH + N + G)
(5) NEMA L21-20
Overload Operation 60 seconds @ 125% and 30 seconds @ 150%
Bypass Built-in Maintenance Bypass, Built-in Static Bypass
Input
Nominal Input Voltage 480V 3PH
Input Frequency 40 - 70 Hz
Input Connections
Hard Wire 4-wire (3PH + G)
Input voltage range for main operations 408 - 552 (480)V
Input Breaker Capacity 40 A
Specifications:OutputOutput Power Capacity 8000 Watts / 10 kVAMax Configurable Power 8000 Watts / 10 kVANominal Output Voltage 400V 3PHOutput Voltage Note Configurable for 380 : 400 or 415 V 3 Phase nominal output voltageEfficiency at Full Load 95.2%Output Voltage Distortion Less than 5% at full loa
Specifications:OutputNominal Output Voltage 208V 3PHInputNominal Input Voltage 208V 3PHInput Frequency 60 HzPhysicalNet Weight 127.00 KGMaximum Height 1487.00 mmMaximum Width 351.00 mmMaximum Depth 837.00 mmShipping Weight 156.00 KGShipping Height 1663.00 mmShipping Width 723.00 mmShipping Depth 110
Specifications:OutputOutput Power Capacity 12 kW / 15 kVAMax Configurable Power 12 kW / 15 kVANominal Output Voltage 400V 3PHOutput Voltage Note Configurable for 380 : 400 or 415 V 3 Phase nominal output voltageEfficiency at Full Load 95.8%Output Voltage Distortion Less than 5%Output Frequency (sync
Specifications:GeneralBypass Connection 5 wire 3PH + N +GMax Bypass Input Current 162ABypass Protection Device 175AOutputOutput Power Capacity 10 kW / 10 kVAMax Configurable Power 40 kW / 40 kVANominal Output Voltage 120V, 208V, 208V 3PHOutput Voltage Distortion Less than 5%Output Frequency (sync to
Specifications:GeneralBypass Connection 5 wire (3PH + N + G)Bypass Voltage Tolerance +/- 15%Max Bypass Input Current 180AOutputOutput Power Capacity 52 kW / 65 kVAMax Configurable Power 52 kW / 65 kVANominal Output Voltage 208V 3PHEfficiency at Full Load 87.4%Output Voltage Distortion Less than 3%Ou
Specifications:OutputOutput Power Capacity 4200 Watts / 6000 VAMax Configurable Power 4200 Watts / 6000 VANominal Output Voltage 120V, 208VOutput Voltage Note Configurable for 208 or 240 nominal output voltageEfficiency at Full Load 92.0%Output Voltage Distortion Less than 3%Output Frequency (sync t
Specifications:OutputOutput Power Capacity 75 Watts / 125 VAMax Configurable Power 75 Watts / 125 VANominal Output Voltage 120VOutput Frequency (sync to mains) 50/60 Hz +/-1 HzWaveform Type Square waveOutput Connections(3) NEMA 1-15R (Battery Backup) InputNominal Input Voltage 120VInput Frequency 50
Back-UPS Describtion:APC Back-UPS,210 Watts /350 VA,Input 230V /Output 230V, Interface Port Optional Simple Signalling RS232 cable, USBIncludes: CD with software, Documentation CD, Qty 1 - Detachable 1.2 m IEC power cord, Qty 1 - Detachable 1.8 m IEC power cord, Telephone Cable, USB cable, Warran
Specifications:OutputOutput Power Capacity 24 kW / 30 kVAMax Configurable Power 24 kW / 30 kVANominal Output Voltage 400V 3PHOutput Voltage Note Configurable for 380 : 400 or 415 V 3 Phase nominal output voltageEfficiency at Full Load 95.8%Output Voltage Distortion Less than 5%Output Frequency (sync
Specifications:OutputOutput Power Capacity 16 kW / 20 kVAMax Configurable Power 16 kW / 20 kVANominal Output Voltage 120V, 208V, 208V 3PHOutput Voltage Note Configurable for 200 : 208 or 220V 3 Phase nominal output voltageOutput Voltage Distortion Less than 5% at full loadOutput Frequency (sync to m