Specifications:
General
Bypass Connection Built-in Static Bypass
Bypass Voltage Tolerance +/-10% settable from +/-4/6/8 and 10%
Max Bypass Input Current 350A
Bypass Protection Device 400A
Output
Output Power Capacity 202.5 kW / 225 kVA
Max Configurable Power 202.5 kW / 225 kVA
Nominal Output Voltage 480V 3PH
Output Voltage Distortion Less than 2%
Output Frequency (sync to mains) 50/60 Hz +/-1 Hz
Crest Factor Unlimited
Topology Double Conversion Online
Waveform Type Sine wave
Output Connections
(1) Hard Wire 4-wire (3PH + G)
(1) Hard Wire 5-wire (3PH + N + G)
Output Voltage Tolerance +/- 1% static and +/- 3% at 100% load step
Output Voltage THD < 2% linear load and <3% non-linear load
Overload Operation 10 minutes @ 125% and 60 seconds @ 150%
Neutral Output Current 244A
Bypass Built-in Static Bypass
Input
Nominal Input Voltage 480V 3PH
Input Frequency 40 - 70 Hz
Input Connections
Hard Wire 3-wire (3PH + G)
Input voltage range for main operations 360 - 576 (480)V
Input voltage adjustable range for mains operation 360 - 576 (480)V
Maximum Input Current 347A
Input Breaker Capacity 600 A
Maximum Short Circuit Withstand (Icw) 65.0 kA
Input Total Harmonic Distortion Less than 3% for full load
Type of Input Protection Required 3-pole breaker

APC MGE Galaxy 3500 UPS G35T15KHS
APC MGE Galaxy 3500 UPS G35T15KHS
Specifications:OutputOutput Power Capacity 12 kW / 15 kVAMax Configurable Power 12 kW / 15 kVANominal Output Voltage 400V 3PHOutput Voltage Note Configurable for 380 : 400 or 415 V 3 Phase nominal output voltageEfficiency at Full Load 95.8%Output Voltage Distortion Less than 5%Output Frequency (sync
APC MGE Galaxy 3500 UPS G35T20K3I2B2S
APC MGE Galaxy 3500 UPS G35T20K3I2B2S
Specifications:OutputOutput Power Capacity 16 kW / 20 kVAMax Configurable Power 16 kW / 20 kVANominal Output Voltage 230VOutput Voltage Note Configurable for 220 : 230 or 240 nominal output voltageEfficiency at Full Load 95.3%Output Voltage Distortion Less than 5%Output Frequency (sync to mains) 47
APC MGE Galaxy 3500 UPS G35T15K3I4B4S
APC MGE Galaxy 3500 UPS G35T15K3I4B4S
Specifications:OutputOutput Power Capacity 12 kW / 15 kVAMax Configurable Power 12 kW / 15 kVANominal Output Voltage 230VOutput Voltage Note Configurable for 220 : 230 or 240 nominal output voltageEfficiency at Full Load 95.5%Output Voltage Distortion Less than 5%Output Frequency (sync to mains) 47
APC MGE Galaxy 3500 UPS G35T10KF3B4S
APC MGE Galaxy 3500 UPS G35T10KF3B4S
Specifications:OutputOutput Power Capacity 8000 Watts / 10 kVAMax Configurable Power 8000 Watts / 10 kVANominal Output Voltage 208V 3PHOutput Voltage Note Configurable for 200 : 208 or 220V 3 Phase nominal output voltageEfficiency at Full Load 93.2%Output Voltage Distortion Less than 3%Output Freque
APC Symmetra PX UPS SY200K250DR-PD
APC Symmetra PX UPS SY200K250DR-PD
Specifications:GeneralBypass Voltage Tolerance +/-10% settable from +/-4/6/8 and 10%OutputOutput Power Capacity 200 kW / 200 kVAMax Configurable Power 500 kW / 500 kVANominal Output Voltage 400V 3PH, 480V 3PHOutput Voltage Distortion Less than 2%Output Frequency (sync to mains) 50 Hz, 60 HzOther Out
APC MGE Galaxy 4000 UPS G4TUPS75
APC MGE Galaxy 4000 UPS G4TUPS75
Specifications: General Bypass Connection 5 wire (3PH + N + G) Bypass Voltage Tolerance +/- 15% Max Bypass Input Current 208A Output Output Power Capacity 60 kW / 75 kVA Max Configurable Power 60 kW / 75 kVA Nominal Output Voltage 208V 3PH Efficiency at Full Load 87.4% Output Voltage Disto
APC Back-UPS BH500NET
APC Back-UPS BH500NET
Back-UPS specification:Output Power Capacity 300 Watts / 500 VAMax Configurable Power 300 Watts / 500 VANominal Output Voltage 120VTopology StandbyOutput Connections(4) NEMA 5-15R (Battery Backup) NEMA 5-15RInputNominal Input Voltage 120VInput Frequency 47 - 63 HzInput ConnectionsNEMA 5-15P NEMA 5-1
APC Smart-UPS SURT8000XLI
APC Smart-UPS SURT8000XLI
Specifications:OutputOutput Power Capacity 6400 Watts / 8000 VAMax Configurable Power 6400 Watts / 8000 VANominal Output Voltage 230VOutput Voltage Note Configurable for 220 : 230 or 240 nominal output voltageOutput Voltage Distortion Less than 3%Output Frequency (sync to mains) 50/60 Hz +/- 3 Hz us
APC Smart-UPS SUA1000RM2U
APC Smart-UPS SUA1000RM2U
Destribtions:APC Smart-UPS,670 Watts /1000 VA,Input 120V /Output 120V, Interface Port DB-9 RS-232, SmartSlot, USB, Rack Height 2 UIncludes: CD with software, Rack Mounting brackets, Rack Mounting support rails, Smart UPS signalling RS-232 cable, USB cable, User ManualStandard Lead Time: Usually in S
APC MGE Galaxy 4000 UPS G4TUPS50
APC MGE Galaxy 4000 UPS G4TUPS50
Specifications: General Bypass Connection 5 wire (3PH + N + G) Bypass Voltage Tolerance +/- 15% Max Bypass Input Current 139A Output Output Power Capacity 40 kW / 50 kVA Max Configurable Power 40 kW / 50 kVA Nominal Output Voltage 208V 3PH Efficiency at Full Load 89.0% Output Voltage Disto