Specifications:
Output
Output Power Capacity 12.8 kW / 16 kVA
Max Configurable Power 12.8 kW / 16 kVA
Nominal Output Voltage 120V, 208V
Output Voltage Note Configurable for 120/208 or 120/240 output voltage
Output Voltage Distortion Less than 5% at full load
Output Frequency (sync to mains) 47 - 63 Hz
Other Output Voltages 240
Crest Factor up to 5 : 1
Topology Double Conversion Online
Waveform Type Sine wave
Output Connections
(1) Hard Wire 4-wire (2PH + N +G)
(4) NEMA L14-30R NEMA L14-30R
(8) NEMA L5-20R NEMA L5-20R
Bypass Internal Bypass (Automatic and Manual), Optional External Bypass
Input
Nominal Input Voltage 208V
Input Frequency 45 - 65 Hz (auto sensing)
Input Connections
Hard Wire 4-wire (2PH+N+G)
Input voltage range for main operations 96 - 138 (Line to Neutral)V
Other Input Voltages 240V
Input Total Harmonic Distortion Less than 7% for full load

APC Smart-UPS VT SUVTR20KF4B5S
APC Smart-UPS VT SUVTR20KF4B5S
Specifications:OutputOutput Power Capacity 16 kW / 20 kVAMax Configurable Power 16 kW / 20 kVANominal Output Voltage 120V, 208V, 208V 3PHOutput Voltage Note Configurable for 200 : 208 or 220V 3 Phase nominal output voltageOutput Voltage Distortion Less than 5% at full loadOutput Frequency (sync to m
APC Smart-UPS SUA750
APC Smart-UPS SUA750
Smart-UPS specification:OutputOutput Power Capacity 500 Watts / 750 VAMax Configurable Power 500 Watts / 750 VANominal Output Voltage 120VOutput Voltage Distortion Less than 5% at full loadOutput Frequency (sync to mains) 47 - 53 Hz for 50 Hz nominal, 57 - 63 Hz for 60 Hz nominalTopology Line Intera
APC MGE Galaxy 3500 UPS G35T40KHS
APC MGE Galaxy 3500 UPS G35T40KHS
Specifications:OutputOutput Power Capacity 32 kW / 40 kVAMax Configurable Power 32 kW / 40 kVANominal Output Voltage 400V 3PHOutput Voltage Note Configurable for 380 : 400 or 415 V 3 Phase nominal output voltageEfficiency at Full Load 95.8%Output Voltage Distortion Less than 5%Output Frequency (sync
APC Smart-UPS SUA5000RMT5U
APC Smart-UPS SUA5000RMT5U
Destribtions:APC Smart-UPS,4000 Watts /5000 VA,Input 208V /Output 208V, Interface Port DB-9 RS-232, SmartSlot, Rack Height 5 UIncludes: CD with software, Rack Mounting support rails, Smart UPS signalling RS-232 cable, User Manual, Web/SNMP Management CardStandard Lead Time: Usually Ships within 3 We
APC Symmetra UPS SYA12K16PXR
APC Symmetra UPS SYA12K16PXR
Specifications:OutputOutput Power Capacity 9600 Watts / 12 kVAMax Configurable Power 12.8 kW / 16 kVANominal Output Voltage 120V, 208VOutput Voltage Note Configurable for 120/208 or 120/240 output voltageOutput Voltage Distortion Less than 5% at full loadOutput Frequency (sync to mains) 47 - 63 HzOt
APC Smart-UPS SURTA2200XL
APC Smart-UPS SURTA2200XL
Specifications:OutputOutput Power Capacity 1600 Watts / 2200 VAMax Configurable Power 1600 Watts / 2200 VANominal Output Voltage 120VOutput Voltage Distortion Less than 3%Output Frequency (sync to mains) 50/60 Hz +/- 3 Hz user adjustable +/- 0.1Crest Factor 3 : 1Topology Double Conversion OnlineWave
APC Symmetra PX UPS SY125K500D
APC Symmetra PX UPS SY125K500D
Specifications:GeneralBypass Voltage Tolerance +/-10% settable from +/-4/6/8 and 10%OutputOutput Power Capacity 125 kW / 125 kVAMax Configurable Power 500 kW / 500 kVANominal Output Voltage 400V 3PH, 480V 3PHOutput Voltage Distortion Less than 2%Output Frequency (sync to mains) 50 Hz, 60 HzOther Out
APC Smart-UPS SURT6KRMXL3U-TF5
APC Smart-UPS SURT6KRMXL3U-TF5
Specifications:OutputOutput Power Capacity 4200 Watts / 6000 VAMax Configurable Power 4200 Watts / 6000 VANominal Output Voltage 120V, 208VOutput Voltage Note Configurable for 208 or 240 nominal output voltageEfficiency at Full Load 92.0%Output Voltage Distortion Less than 3%Output Frequency (sync t
APC Galaxy VM UPS GVMPB225KGS
APC Galaxy VM UPS GVMPB225KGS
Specifications:GeneralBypass Connection Built-in Static BypassBypass Voltage Tolerance +/-10% settable from +/-4/6/8 and 10%Max Bypass Input Current 350ABypass Protection Device 400AOutputOutput Power Capacity 202.5 kW / 225 kVAMax Configurable Power 202.5 kW / 225 kVANominal Output Voltage 480V 3PH
APC MGE Galaxy 5000 UPS SUG550S90UL
APC MGE Galaxy 5000 UPS SUG550S90UL
Specifications:OutputOutput Power Capacity 45 kW / 50 kVAMax Configurable Power 45 kW / 0 VANominal Output Voltage 480V 3PH, 600V 3PHEfficiency at Full Load 93.3%Output Voltage Distortion Less than 5%Output Frequency (sync to mains) 60 HzCrest Factor 3 : 1Topology Double Conversion OnlineWaveform Ty