Specifications:
Output
Output Power Capacity 24 kW / 30 kVA
Max Configurable Power 24 kW / 30 kVA
Nominal Output Voltage 400V 3PH
Output Voltage Note Configurable for 380 : 400 or 415 V 3 Phase nominal output voltage
Efficiency at Full Load 95.8%
Output Voltage Distortion Less than 5%
Output Frequency (sync to mains) 47 - 53 Hz for 50 Hz nominal, 60 Hz
Other Output Voltages 380, 415
Crest Factor Unlimited
Topology Double Conversion Online
Waveform Type Sine wave
Output Connections
(1) Hard Wire 4-wire (3PH + G)
(1) Hard Wire 5-wire (3PH + N + G)
(1) Screw Terminals
Output Voltage Tolerance +/-1% static and +/- 5% at 100% load step
Output Voltage THD < 2% for 0 to 100% linear load and < 5% for full non linear load
Overload Operation 10 minutes @ 125% and 60 seconds @ 150%
Efficiency at Half Load 95.5%
Required Output Current Protection 50A
Bypass Built-in Maintenance Bypass, Built-in Static Bypass
Input
Nominal Input Voltage 400V 3PH
Input Frequency 40 - 70 Hz (auto sensing)
Input Connections
Hard Wire 5-wire (3PH + N + G)
Input voltage range for main operations 304 - 477V
Input voltage adjustable range for mains operation 340 - 460 (400V)V
Other Input Voltages 380, 415
Maximum Input Current 43A
Input Breaker Capacity 50 A
Input Total Harmonic Distortion Less than 5% for full load
Type of Input Protection Required 3-pole breaker

APC Smart-UPS SURTA1000XL
APC Smart-UPS SURTA1000XL
Specifications:OutputOutput Power Capacity 800 Watts / 1000 VAMax Configurable Power 800 Watts / 1000 VANominal Output Voltage 120VOutput Voltage Distortion Less than 3%Output Frequency (sync to mains) 50/60 Hz +/- 3 Hz user adjustable +/- 0.1Crest Factor 3 : 1Topology Double Conversion OnlineWavefo
APC Smart-UPS VT SUVTSBPXFM10K30F
APC Smart-UPS VT SUVTSBPXFM10K30F
Specifications:OutputNominal Output Voltage 208V 3PHInputNominal Input Voltage 208V 3PHInput Frequency 60 HzPhysicalNet Weight 332.00 KGMaximum Height 1487.00 mmMaximum Width 351.00 mmMaximum Depth 837.00 mmShipping Weight 365.00 KGShipping Height 1663.00 mmShipping Width 723.00 mmShipping Depth 110
APC MGE Galaxy 3500 UPS G35T40KH4B4S
APC MGE Galaxy 3500 UPS G35T40KH4B4S
Specifications:OutputOutput Power Capacity 32 kW / 40 kVAMax Configurable Power 32 kW / 40 kVANominal Output Voltage 400V 3PHOutput Voltage Note Configurable for 380 : 400 or 415 V 3 Phase nominal output voltageEfficiency at Full Load 95.8%Output Voltage Distortion Less than 5%Output Frequency (sync
APC MGE Galaxy 5000 UPS G5TUPS80
APC MGE Galaxy 5000 UPS G5TUPS80
Specifications:OutputOutput Power Capacity 72 kW / 80 kVAMax Configurable Power 72 kW / 80 kVANominal Output Voltage 400V 3PH, 480V 3PH, 600V 3PHOutput Voltage Note Configurable for 380 : 400 or 415 V 3 Phase nominal output voltageEfficiency at Full Load 92.8%Output Voltage Distortion Less than 2%Ou
APC Smart-UPS SURT10000XLT-1TF10K
APC Smart-UPS SURT10000XLT-1TF10K
Specifications:OutputOutput Power Capacity 8000 Watts / 10 kVAMax Configurable Power 8000 Watts / 10 kVANominal Output Voltage 120V, 208VOutput Voltage Note Configurable for 208 or 240 nominal output voltageEfficiency at Full Load 92.0%Output Voltage Distortion Less than 3%Output Frequency (sync to
APC Back-UPS BX1100CI-LM
APC Back-UPS BX1100CI-LM
Back-UPS specification:Output Power Capacity 660 Watts / 1100 VAMax Configurable Power 660 Watts / 1100 VANominal Output Voltage 120VEfficiency at Full Load 97.0%Output Frequency (sync to mains) 50/60Hz +/- 3 HzTopology Line InteractiveWaveform Type Stepped approximation to a sinewaveOutput Connecti
APC Smart-UPS VT SUVTP30KH4B4S
APC Smart-UPS VT SUVTP30KH4B4S
Specifications:OutputOutput Power Capacity 24 kW / 30 kVAMax Configurable Power 24 kW / 30 kVANominal Output Voltage 400V 3PHOutput Voltage Note Configurable for 380 : 400 or 415 V 3 Phase nominal output voltageEfficiency at Full Load 96.4%Output Voltage Distortion Less than 5% at full loadOutput Fr
APC Smart-UPS VT SUVTR30KG3B5S
APC Smart-UPS VT SUVTR30KG3B5S
Specifications:OutputOutput Power Capacity 24 kW / 30 kVAMax Configurable Power 24 kW / 30 kVANominal Output Voltage 120V, 208V, 208V 3PHOutput Voltage Note Configurable for 200 : 208 or 220V 3 Phase nominal output voltageEfficiency at Full Load 93.3%Output Voltage Distortion Less than 5% at full lo
APC Galaxy VM UPS GVMRB160KGS
APC Galaxy VM UPS GVMRB160KGS
Specifications:GeneralBypass Connection Built-in Static BypassBypass Voltage Tolerance +/-10% settable from +/-4/6/8 and 10%Max Bypass Input Current 217ABypass Protection Device 400AOutputOutput Power Capacity 144 kW / 160 kVAMax Configurable Power 144 kW / 160 kVANominal Output Voltage 480V 3PHOutp
APC Galaxy VM UPS GVMSBCLB675KG
APC Galaxy VM UPS GVMSBCLB675KG
Specifications:OutputNominal Output Voltage 480V 3PHOutput Connections(1) Hard Wire 4-wire (3PH + G) (1) Hard Wire 5-wire (3PH + N + G) InputNominal Input Voltage 480V 3PHInput Frequency 40 - 70 HzPhysicalNet Weight 1287.00 lbs. (585.00 kg)Maximum Height 77.56 inches (1970 mm)Maximum Width 70.28 inc