Home / Products / UPS Power Supply / APC UPS Power Supply / APC Galaxy VM UPS / APC Galaxy VM UPS GVMPB160KGS

APC Galaxy VM UPS GVMPB160KGS

APC Galaxy VM UPS GVMPB160KGS
share

Specifications:
General
Bypass Connection Built-in Static Bypass
Bypass Voltage Tolerance +/-10% settable from +/-4/6/8 and 10%
Max Bypass Input Current 217A
Bypass Protection Device 400A
Output
Output Power Capacity 144 kW / 160 kVA
Max Configurable Power 144 kW / 160 kVA
Nominal Output Voltage 480V 3PH
Output Voltage Distortion Less than 2%
Output Frequency (sync to mains) 50/60 Hz +/-1 Hz
Crest Factor Unlimited
Topology Double Conversion Online
Waveform Type Sine wave
Output Connections
(1) Hard Wire 4-wire (3PH + G)
(1) Hard Wire 5-wire (3PH + N + G)
Output Voltage Tolerance +/- 1% static and +/- 3% at 100% load step
Output Voltage THD < 2% linear load and <3% non-linear load
Overload Operation 10 minutes @ 125% and 60 seconds @ 150%
Required Output Current Protection 300A
Neutral Output Current 195A
Bypass Built-in Static Bypass
Input
Nominal Input Voltage 480V 3PH
Input Frequency 40 - 70 Hz
Input Connections
Hard Wire 3-wire (3PH + G)
Input voltage range for main operations 360 - 576 (480)V
Input voltage adjustable range for mains operation 360 - 576 (480)V
Maximum Input Current 278A
Input Breaker Capacity 400 A
Maximum Short Circuit Withstand (Icw) 65.0 kA
Input Total Harmonic Distortion Less than 3% for full load
Type of Input Protection Required 3-pole breaker

APC Symmetra PX UPS SY300K500D
APC Symmetra PX UPS SY300K500D
Specifications:GeneralBypass Voltage Tolerance +/-10% settable from +/-4/6/8 and 10%OutputOutput Power Capacity 300 kW / 300 kVAMax Configurable Power 500 kW / 500 kVANominal Output Voltage 400V 3PH, 480V 3PHOutput Voltage Distortion Less than 2%Output Frequency (sync to mains) 50 Hz, 60 HzOther Out
APC Back-UPS Connect BGE70
APC Back-UPS Connect BGE70
Specifications:OutputOutput Power Capacity 75 Watts / 125 VAMax Configurable Power 75 Watts / 125 VANominal Output Voltage 120VOutput Frequency (sync to mains) 50/60Hz +/- 3 HzWaveform Type Square waveOutput Connections(3) NEMA 1-15R (Battery Backup) InputNominal Input Voltage 120VInput Frequency 50
APC Symmetra PX UPS SY10K40F
APC Symmetra PX UPS SY10K40F
Specifications:GeneralBypass Connection 5 wire 3PH + N +GMax Bypass Input Current 162ABypass Protection Device 175AOutputOutput Power Capacity 10 kW / 10 kVAMax Configurable Power 40 kW / 40 kVANominal Output Voltage 120V, 208V, 208V 3PHOutput Voltage Distortion Less than 5%Output Frequency (sync to
APC MGE EPS 7000 UPS E7TUPS300
APC MGE EPS 7000 UPS E7TUPS300
Specifications:GeneralMax Bypass Input Current 361AOutputOutput Power Capacity 270 kW / 300 kVAMax Configurable Power 270 kW / 300 kVANominal Output Voltage 480V 3PH, 600V 3PHEfficiency at Full Load 93.5%Output Voltage Distortion Less than 2%Output Frequency (sync to mains) 60 HzOther Output Voltage
APC Symmetra UPS SYA8K16PXR
APC Symmetra UPS SYA8K16PXR
Specifications:OutputOutput Power Capacity 6400 Watts / 8000 VAMax Configurable Power 12.8 kW / 16 kVANominal Output Voltage 120V, 208VOutput Voltage Note Configurable for 120/208 or 120/240 output voltageOutput Voltage Distortion Less than 5% at full loadOutput Frequency (sync to mains) 47 - 63 HzO
APC Smart-UPS SURT10KRMXL6U-TF5
APC Smart-UPS SURT10KRMXL6U-TF5
Specifications:OutputOutput Power Capacity 8000 Watts / 10 kVAMax Configurable Power 8000 Watts / 10 kVANominal Output Voltage 120V, 208VOutput Voltage Note Configurable for 208 or 240 nominal output voltageEfficiency at Full Load 92.0%Output Voltage Distortion Less than 3%Output Frequency (sync to
APC Smart-UPS VT SUVTR20KG5B5S
APC Smart-UPS VT SUVTR20KG5B5S
Specifications:OutputOutput Power Capacity 16 kW / 20 kVAMax Configurable Power 16 kW / 20 kVANominal Output Voltage 120V, 208V, 208V 3PHOutput Voltage Note Configurable for 200 : 208 or 220V 3 Phase nominal output voltageEfficiency at Full Load 93.8%Output Voltage Distortion Less than 5% at full lo
APC MGE Galaxy 3500 UPS G35T20KF2B4S
APC MGE Galaxy 3500 UPS G35T20KF2B4S
Specifications:OutputOutput Power Capacity 16 kW / 20 kVAMax Configurable Power 16 kW / 20 kVANominal Output Voltage 208V 3PHOutput Voltage Note Configurable for 200 : 208 or 220V 3 Phase nominal output voltageEfficiency at Full Load 93.4%Output Voltage Distortion Less than 3%Output Frequency (sync
APC Smart-UPS VT SUVTP20KH3B4S
APC Smart-UPS VT SUVTP20KH3B4S
Specifications:OutputOutput Power Capacity 16 kW / 20 kVAMax Configurable Power 16 kW / 20 kVANominal Output Voltage 400V 3PHOutput Voltage Note Configurable for 380 : 400 or 415 V 3 Phase nominal output voltageEfficiency at Full Load 95.3%Output Voltage Distortion Less than 5% at full loadOutput Fr
APC Smart-UPS VT SUVTP40KH4B4S
APC Smart-UPS VT SUVTP40KH4B4S
Specifications:OutputOutput Power Capacity 32 kW / 40 kVAMax Configurable Power 32 kW / 40 kVANominal Output Voltage 400V 3PHOutput Voltage Note Configurable for 380 : 400 or 415 V 3 Phase nominal output voltageEfficiency at Full Load 96.0%Output Voltage Distortion Less than 5% at full loadOutput Fr