Specifications:
General
Bypass Connection Built-in Static Bypass
Bypass Voltage Tolerance +/-10% settable from +/-4/6/8 and 10%
Max Bypass Input Current 217A
Bypass Protection Device 400A
Output
Output Power Capacity 144 kW / 160 kVA
Max Configurable Power 144 kW / 160 kVA
Nominal Output Voltage 480V 3PH
Output Voltage Distortion Less than 2%
Output Frequency (sync to mains) 50/60 Hz +/-1 Hz
Crest Factor Unlimited
Topology Double Conversion Online
Waveform Type Sine wave
Output Connections
(1) Hard Wire 4-wire (3PH + G)
(1) Hard Wire 5-wire (3PH + N + G)
Output Voltage Tolerance +/- 1% static and +/- 3% at 100% load step
Output Voltage THD < 2% linear load and <3% non-linear load
Overload Operation 10 minutes @ 125% and 60 seconds @ 150%
Required Output Current Protection 300A
Neutral Output Current 195A
Bypass Built-in Static Bypass
Input
Nominal Input Voltage 480V 3PH
Input Frequency 40 - 70 Hz
Input Connections
Hard Wire 3-wire (3PH + G)
Input voltage range for main operations 360 - 576 (480)V
Input voltage adjustable range for mains operation 360 - 576 (480)V
Maximum Input Current 278A
Input Breaker Capacity 400 A
Maximum Short Circuit Withstand (Icw) 65.0 kA
Input Total Harmonic Distortion Less than 3% for full load
Type of Input Protection Required 3-pole breaker

APC Smart-UPS SUA2200RM2U
APC Smart-UPS SUA2200RM2U
Destribtions:APC Smart-UPS,1980 Watts /2200 VA,Input 120V /Output 120V, Interface Port DB-9 RS-232, SmartSlot, USB, Rack Height 2 UIncludes: CD with software, Rack Mounting support rails, Smart UPS signalling RS-232 cable, USB cable, User ManualStandard Lead Time: Usually in Stock
APC Smart-UPS SURTD5000RMXLP3U
APC Smart-UPS SURTD5000RMXLP3U
Specifications:OutputOutput Power Capacity 4000 Watts / 5000 VAMax Configurable Power 4000 Watts / 5000 VANominal Output Voltage 120V, 208VOutput Voltage Note Configurable for 208 or 240 nominal output voltageEfficiency at Full Load 90.0%Output Voltage Distortion Less than 2%Output Frequency (sync t
APC Symmetra PX UPS SY250K500D
APC Symmetra PX UPS SY250K500D
Specifications:GeneralBypass Voltage Tolerance +/-10% settable from +/-4/6/8 and 10%OutputOutput Power Capacity 250 kW / 250 kVAMax Configurable Power 500 kW / 500 kVANominal Output Voltage 400V 3PH, 480V 3PHOutput Voltage Distortion Less than 2%Output Frequency (sync to mains) 50 Hz, 60 HzOther Out
APC MGE Galaxy 4000 UPS G4TUPS65
APC MGE Galaxy 4000 UPS G4TUPS65
Specifications:GeneralBypass Connection 5 wire (3PH + N + G)Bypass Voltage Tolerance +/- 15%Max Bypass Input Current 180AOutputOutput Power Capacity 52 kW / 65 kVAMax Configurable Power 52 kW / 65 kVANominal Output Voltage 208V 3PHEfficiency at Full Load 87.4%Output Voltage Distortion Less than 3%Ou
APC Symmetra PX UPS SY500K500D
APC Symmetra PX UPS SY500K500D
Specifications:GeneralBypass Voltage Tolerance +/-10% settable from +/-4/6/8 and 10%OutputOutput Power Capacity 500 kW / 500 kVAMax Configurable Power 500 kW / 500 kVANominal Output Voltage 400V 3PH, 480V 3PHOutput Voltage Distortion Less than 2%Output Frequency (sync to mains) 50 Hz, 60 HzOther Out
APC MGE Galaxy 3500 UPS G35T15KF3B4S
APC MGE Galaxy 3500 UPS G35T15KF3B4S
Specifications:OutputOutput Power Capacity 12 kW / 15 kVAMax Configurable Power 12 kW / 15 kVANominal Output Voltage 208V 3PHOutput Voltage Note Configurable for 200 : 208 or 220V 3 Phase nominal output voltageEfficiency at Full Load 93.0%Output Voltage Distortion Less than 3%Output Frequency (sync
APC Symmetra UPS SYH6K6RMT-TF3
APC Symmetra UPS SYH6K6RMT-TF3
Specifications:OutputOutput Power Capacity 4200 Watts / 6000 VAMax Configurable Power 4200 Watts / 6000 VANominal Output Voltage 120V, 208VOutput Voltage Note Configurable for 208 or 240 nominal output voltageEfficiency at Full Load 85.0%Output Voltage Distortion Less than 5% at full loadOutput Freq
APC Symmetra PX UPS SY150K250DR-PD
APC Symmetra PX UPS SY150K250DR-PD
Specifications:GeneralBypass Voltage Tolerance +/-10% settable from +/-4/6/8 and 10%OutputOutput Power Capacity 150 kW / 150 kVAMax Configurable Power 500 kW / 500 kVANominal Output Voltage 400V 3PH, 480V 3PHOutput Voltage Distortion Less than 2%Output Frequency (sync to mains) 50 Hz, 60 HzOther Out
APC Symmetra PX UPS SY100K250DR-PD
APC Symmetra PX UPS SY100K250DR-PD
Specifications:GeneralBypass Voltage Tolerance +/-10% settable from +/-4/6/8 and 10%OutputOutput Power Capacity 100 kW / 100 kVAMax Configurable Power 500 kW / 500 kVANominal Output Voltage 400V 3PH, 480V 3PHOutput Voltage Distortion Less than 2%Output Frequency (sync to mains) 50 Hz, 60 HzOther Out
APC Back-UPS BE750G
APC Back-UPS BE750G
Back-UPS specification:Output Power Capacity 450 Watts / 750 VAMax Configurable Power 450 Watts / 750 VANominal Output Voltage 120VOutput Frequency (sync to mains) 50/60Hz +/- 3 HzTopology StandbyWaveform Type Stepped approximation to a sinewaveOutput Connections(5) NEMA 5-15R (Battery Backup) NEMA