Specifications:General
Bypass Voltage Tolerance +/-10% settable from +/-4/6/8 and 10%
Output
Output Power Capacity 125 kW / 125 kVA
Max Configurable Power 500 kW / 500 kVA
Nominal Output Voltage 400V 3PH, 480V 3PH
Output Voltage Distortion Less than 2%
Output Frequency (sync to mains) 50 Hz, 60 Hz
Other Output Voltages 415
Crest Factor Unlimited
Topology Double Conversion Online
Waveform Type Sine wave
Output Connections
(1) Hard Wire 4-wire (3PH + G)
(1) Hard Wire 5-wire (3PH + N + G)
Output Voltage Tolerance +/-1% static and +/- 5% at 100% load step
Output Voltage THD < 2% linear load and <3% non-linear load
Overload Operation 10 minutes @ 125% and 60 seconds @ 150%
Bypass Built-in Maintenance Bypass, Built-in Static Bypass
Input
Nominal Input Voltage 400V 3PH, 480V 3PH
Input Frequency 40 - 70 Hz (auto sensing)
Input Connections
Hard Wire 4-wire (3PH + G)
Hard Wire 5-wire (3PH + N + G)
Input voltage range for main operations 408 - 552 (480)V
Other Input Voltages 415
Maximum Short Circuit Withstand (Icw) 50.0 kA
Input Total Harmonic Distortion Less than 5% for full load
Type of Input Protection Required 3-pole breaker

APC Galaxy VM UPS GVMRB160KGS
APC Galaxy VM UPS GVMRB160KGS
Specifications:GeneralBypass Connection Built-in Static BypassBypass Voltage Tolerance +/-10% settable from +/-4/6/8 and 10%Max Bypass Input Current 217ABypass Protection Device 400AOutputOutput Power Capacity 144 kW / 160 kVAMax Configurable Power 144 kW / 160 kVANominal Output Voltage 480V 3PHOutp
APC Symmetra PX UPS SY125K500DR-PDNB
APC Symmetra PX UPS SY125K500DR-PDNB
Specifications:GeneralBypass Voltage Tolerance +/-10% settable from +/-4/6/8 and 10%OutputOutput Power Capacity 125 kW / 125 kVAMax Configurable Power 500 kW / 500 kVANominal Output Voltage 400V 3PH, 480V 3PHOutput Voltage Distortion Less than 2%Output Frequency (sync to mains) 50 Hz, 60 HzOther Out
APC MGE Galaxy 3500 UPS G35T20KH3B4S
APC MGE Galaxy 3500 UPS G35T20KH3B4S
Specifications:OutputOutput Power Capacity 16 kW / 20 kVAMax Configurable Power 16 kW / 20 kVANominal Output Voltage 400V 3PHEfficiency at Full Load 95.7%Output Frequency (sync to mains) 47 - 53 Hz for 50 Hz nominalOther Output Voltages 380, 415Crest Factor UnlimitedTopology Double Conversion Online
APC MGE Galaxy 3500 UPS G35T15KF2B2S
APC MGE Galaxy 3500 UPS G35T15KF2B2S
Specifications:OutputOutput Power Capacity 12 kW / 15 kVAMax Configurable Power 12 kW / 15 kVANominal Output Voltage 208V 3PHOutput Voltage Note Configurable for 200 : 208 or 220V 3 Phase nominal output voltageEfficiency at Full Load 93.0%Output Voltage Distortion Less than 3%Output Frequency (sync
APC MGE Galaxy 3500 UPS G35T40KH4B4S
APC MGE Galaxy 3500 UPS G35T40KH4B4S
Specifications:OutputOutput Power Capacity 32 kW / 40 kVAMax Configurable Power 32 kW / 40 kVANominal Output Voltage 400V 3PHOutput Voltage Note Configurable for 380 : 400 or 415 V 3 Phase nominal output voltageEfficiency at Full Load 95.8%Output Voltage Distortion Less than 5%Output Frequency (sync
APC MGE Galaxy 3500 UPS G35T15K3I2B2S
APC MGE Galaxy 3500 UPS G35T15K3I2B2S
Specifications:OutputOutput Power Capacity 12 kW / 15 kVAMax Configurable Power 12 kW / 15 kVANominal Output Voltage 230VOutput Voltage Note Configurable for 220 : 230 or 240 nominal output voltageEfficiency at Full Load 95.5%Output Voltage Distortion Less than 5%Output Frequency (sync to mains) 47
APC Smart-UPS SUM3000RMXL2U
APC Smart-UPS SUM3000RMXL2U
Specifications:OutputOutput Power Capacity 2850 Watts / 3000 VAMax Configurable Power 2850 Watts / 3000 VANominal Output Voltage 120VEfficiency at Full Load 95.0%Topology Line InteractiveOutput Connections(6) NEMA 5-15R NEMA 5-15R(2) NEMA 5-20R NEMA 5-20RBypass Internal Bypass (Automatic and Manual)
APC Symmetra PX UPS SY64K96H-NB
APC Symmetra PX UPS SY64K96H-NB
Specifications:GeneralBypass Connection 5 wire (3PH + N + G)Max Bypass Input Current 250ABypass Protection Device 250AOutputOutput Power Capacity 64 kW / 64 kVAMax Configurable Power 160 kW / 160 kVANominal Output Voltage 230V, 400V 3PHOutput Voltage Note Configurable for 380 : 400 or 415 V 3 Phase
APC Back-UPS Connect BGE90M
APC Back-UPS Connect BGE90M
Specifications:OutputOutput Power Capacity 75 Watts / 125 VAMax Configurable Power 75 Watts / 125 VANominal Output Voltage 120VOutput Frequency (sync to mains) 50/60 Hz +/-1 HzWaveform Type Square waveOutput Connections(3) NEMA 1-15R (Battery Backup) InputNominal Input Voltage 120VInput Frequency 50
APC MGE Galaxy 3500 UPS G35T10KHS
APC MGE Galaxy 3500 UPS G35T10KHS
Specifications:OutputOutput Power Capacity 8000 Watts / 10 kVAMax Configurable Power 8000 Watts / 10 kVANominal Output Voltage 400V 3PHOutput Voltage Note Configurable for 380 : 400 or 415 V 3 Phase nominal output voltageEfficiency at Full Load 94.5%Output Voltage Distortion Less than 5%Output Frequ