Specifications:
General
Bypass Voltage Tolerance +/-10% settable from +/-4/6/8 and 10%
Output
Output Power Capacity 200 kW / 200 kVA
Max Configurable Power 500 kW / 500 kVA
Nominal Output Voltage 400V 3PH, 480V 3PH
Output Voltage Distortion Less than 2%
Output Frequency (sync to mains) 50 Hz, 60 Hz
Other Output Voltages 415
Crest Factor Unlimited
Topology Double Conversion Online
Waveform Type Sine wave
Output Connections
(1) Hard Wire 4-wire (3PH + G)
(1) Hard Wire 5-wire (3PH + N + G)
Output Voltage Tolerance +/-1% static and +/- 5% at 100% load step
Output Voltage THD < 2% for 0 to 100% linear load and < 6% for full non linear load
Overload Operation 10 minutes @ 125% and 30 seconds @ 150%
Bypass Built-in Maintenance Bypass, Built-in Static Bypass
Input
Nominal Input Voltage 400V 3PH, 480V 3PH
Input Frequency 40 - 70 Hz (auto sensing)
Input Connections
Hard Wire 4-wire (3PH + G)
Hard Wire 5-wire (3PH + N + G)
Input voltage range for main operations 340 - 460 (400V), 408 - 552 (480)V
Other Input Voltages 415
Maximum Short Circuit Withstand (Icw) 50.0 kA
Input Total Harmonic Distortion Less than 5% for full load
Type of Input Protection Required 3-pole breaker

APC Smart-UPS VT SUVTP20KH2B4S
APC Smart-UPS VT SUVTP20KH2B4S
Specifications:OutputOutput Power Capacity 16 kW / 20 kVAMax Configurable Power 16 kW / 20 kVANominal Output Voltage 400V 3PHOutput Voltage Note Configurable for 380 : 400 or 415 V 3 Phase nominal output voltageEfficiency at Full Load 95.3%Output Voltage Distortion Less than 5% at full loadOutput Fr
APC Smart-UPS SUA1000XL
APC Smart-UPS SUA1000XL
Specifications:OutputOutput Power Capacity 800 Watts / 1000 VAMax Configurable Power 800 Watts / 1000 VANominal Output Voltage 120VOutput Voltage Distortion Less than 5% at full loadOutput Frequency (sync to mains) 47 - 53 Hz for 50 Hz nominal, 57 - 63 Hz for 60 Hz nominalTopology Line InteractiveWa
APC Smart-UPS SURT15KRMXLT-TF5
APC Smart-UPS SURT15KRMXLT-TF5
Specifications:OutputOutput Power Capacity 12 kW / 15 kVAMax Configurable Power 12 kW / 15 kVANominal Output Voltage 120V, 208VOutput Voltage Note Configurable for 220 : 230 or 240 nominal output voltageOutput Voltage Distortion Less than 5%Output Frequency (sync to mains) 50/60 Hz +/- 3 Hz user adj
APC MGE Galaxy 3500 UPS G35T15KF2B4S
APC MGE Galaxy 3500 UPS G35T15KF2B4S
Specifications:OutputOutput Power Capacity 12 kW / 15 kVAMax Configurable Power 12 kW / 15 kVANominal Output Voltage 208V 3PHOutput Voltage Note Configurable for 200 : 208 or 220V 3 Phase nominal output voltageEfficiency at Full Load 93.0%Output Frequency (sync to mains) 57 - 63 Hz for 60 Hz nominal
APC Smart-UPS SURT20KRMXLT-TF5
APC Smart-UPS SURT20KRMXLT-TF5
Specifications:OutputOutput Power Capacity 16 kW / 20 kVAMax Configurable Power 16 kW / 20 kVANominal Output Voltage 120V, 208VOutput Voltage Distortion Less than 5%Output Frequency (sync to mains) 50/60 Hz +/- 3 Hz user adjustable +/- 0.1Crest Factor 3 : 1Topology Double Conversion OnlineWaveform T
APC Back-UPS BE350G
APC Back-UPS BE350G
Back-UPS specification:Output Power Capacity 200 Watts / 350 VAMax Configurable Power 200 Watts / 350 VANominal Output Voltage 120VOutput Frequency (sync to mains) 50/60Hz +/- 3 HzTopology StandbyWaveform Type Stepped approximation to a sinewaveOutput Connections(3) NEMA 5-15R (Battery Backup) NEM
APC Smart-UPS VT SUVTP15KH4B4S
APC Smart-UPS VT SUVTP15KH4B4S
Specifications:OutputOutput Power Capacity 12 kW / 15 kVAMax Configurable Power 12 kW / 15 kVANominal Output Voltage 400V 3PHOutput Voltage Note Configurable for 380 : 400 or 415 V 3 Phase nominal output voltageEfficiency at Full Load 95.7%Output Voltage Distortion Less than 5% at full loadOutput Fr
APC Galaxy VM UPS GVMPB180KGS
APC Galaxy VM UPS GVMPB180KGS
Specifications:GeneralBypass Connection Built-in Static BypassBypass Voltage Tolerance +/-10% settable from +/-4/6/8 and 10%Max Bypass Input Current 217ABypass Protection Device 400AOutputOutput Power Capacity 162 kW / 180 kVAMax Configurable Power 162 kW / 180 kVANominal Output Voltage 480V 3PHOutp
APC Symmetra PX UPS SY300K500DR-PD
APC Symmetra PX UPS SY300K500DR-PD
Specifications:GeneralBypass Voltage Tolerance +/-10% settable from +/-4/6/8 and 10%OutputOutput Power Capacity 300 kW / 300 kVAMax Configurable Power 500 kW / 500 kVANominal Output Voltage 400V 3PH, 480V 3PHOutput Voltage Distortion Less than 2%Output Frequency (sync to mains) 50 Hz, 60 HzOther Out
APC MGE Galaxy 4000 UPS G4TUPS75
APC MGE Galaxy 4000 UPS G4TUPS75
Specifications: General Bypass Connection 5 wire (3PH + N + G) Bypass Voltage Tolerance +/- 15% Max Bypass Input Current 208A Output Output Power Capacity 60 kW / 75 kVA Max Configurable Power 60 kW / 75 kVA Nominal Output Voltage 208V 3PH Efficiency at Full Load 87.4% Output Voltage Disto