Power Description
Power Rating (VA) 6000
Rated Load Capacity (Watts) 5000
Standard Warranty 2 years parts; 90 days onsite labor
Optional Warranties Cover parts and labor up to 5 years
Electrical Input
Input Voltage 208-240 neutral required
Input Connection Hardwired hardwired terminal
Electrical Output
Output Voltage 208-240/120
Output Connection Hardwired hardwired terminal
Battery Backup
Battery Runtime Minutes (Full Load) 6.5
Battery Runtime Minutes (Half Load) 16
Optional Extended Run Batteries ASY-0529

EATON 9130 Tower UPS PW9130G2000T-XL
EATON 9130 Tower UPS PW9130G2000T-XL
Specifications:Rating (VA/Watts) 2000/1800Diagnostics Full system self-testUPS Bypass Automatic bypassDimensions (H x W x D, inches) 12.8 x 8.4 x 16.1Weight (lbs) 76.1Input Voltage Range 160-276 VacNominal Voltage 208 VACFrequency 50/60 HzFrequency Range 45–65 HzNominal Current 9.6 ABreaker Rating
EATON Emergency Lighting UPS 208V 20 kVA / 18 kW
EATON Emergency Lighting UPS 208V 20 kVA / 18 kW
Specifications:Rating (VA/Watts) 20000/18000Dimensions (H x W x D, inches) 66.0 x 60.0 x 34.1Weight (lbs) 5,280Electrical InputConnection Hardwired - see manual for terminal block layoutHardwired - example layout onlyNominal Voltage 208 VAC 3POperating Frequency 50/60 Hz (45 to 65 Hz)Electrical Outp
EATON POWER XPERT 9395 MARINE UPS 225-1100 KVA
EATON POWER XPERT 9395 MARINE UPS 225-1100 KVA
Describtions:Double-conversion online technology with power ratings 225-1100kVA, three-phase input and output,small foot print, patented Hot Sync parallel capability up to five redundant systems, ABM technology to extend battery service life, wide communication options.
EATON Blade UPS ZC0811104100000
EATON Blade UPS ZC0811104100000
Specifications:Input Voltage 208 Vac modelsVoltage Range 180 to 265 VacInput connection L21-30PFrequency Range 50 or 60 Hz, ±5 HzOutput connection L21-30R, RPM PortRated Output Voltage 180 to 225 Vac, phase to phaseOutput Configuration Three-phase, four-wire + groundOutput Frequency (nominal) 50 or
EATON 5SC UPS 5SC1000
EATON 5SC UPS 5SC1000
Specifications:Rating (VA/Watts) 1000/700Dimensions (H x W x D, inches) 8.2 x 5.9 x 13.4Dimensions (H x W x D, mm) 209 x 150 x 340Weight (kg) 11.6Weight (lbs) 25.6nput Voltage Range 96 - 144 VacNominal Voltage 120VacFrequency 50/60 HzFrequency Range 60 Hz: 55–65 Hz50 Hz: 45–55 HzElectrical Outpu
EATON 9155 UPS K41211000000000
EATON 9155 UPS K41211000000000
Specifications:Rating (VA/Watts) 12000/10800Dimensions (H x W x D, inches) 32.2 x 12 x 33.7Weight (lbs) 352Efficiency 92% with nominal linear load; 91% with nominal computer load.Electrical InputConnection Hardwired - see manual for terminal block layoutElectrical OutputOutput Receptacles (1) PDM
EATON Emergency Lighting UPS 480V 20 kVA / 18 kW
EATON Emergency Lighting UPS 480V 20 kVA / 18 kW
Specifications:Rating (VA/Watts) 20000/18000Dimensions (H x W x D, inches) 66.0 x 80.0 x 34.1Weight (lbs) 6,072Electrical InputConnection Hardwired - see manual for terminal block layoutHardwired - example layout onlyNominal Voltage 480 VAC 3POperating Frequency 50/60 Hz (45 to 65 Hz)Electrical Outp
EATON 9355 UPS KA1512100000010
EATON 9355 UPS KA1512100000010
Describtions:Eaton 9355 15KVA 64-Battery hardwired input and output 208v three phase UPS.Hardwired input and output 208v three phase64 Battery (3 High) tower configurationStandard backup runtime 13 minutes at full loadRear mounted bypass switch and optional output receptaclesDim. 47.8"H x 12"W x 33.
EATON 9130 Tower UPS PW9130G2000T-XLEU
EATON 9130 Tower UPS PW9130G2000T-XLEU
Specifications:Rating (VA/Watts) 2000/1800Diagnostics Full system self-testUPS Bypass Automatic bypassDimensions (H x W x D, inches) 12.8 x 8.4 x 16.1Weight (lbs) 76.1Nominal Voltage 208 VACFrequency 50/60 HzFrequency Range 45–65 HzNominal Current 9.6 ABreaker Ratings 10AElectrical OutputOn Utilit
EATON 3S UPS 3S750
EATON 3S UPS 3S750
Specifications:Rating (VA/Watts) 750/450Diagnostics Full system self-test at power upEcoControl For up to 30% energy savings (with UPS Companion software)Dimensions (H x W x D, inches) 3.4 x 6.7 x 13.2Weight (lbs) 9.7Input Cord 6-foot line cord with 90° 5-15PInput Voltage Range 89–151 VacNominal