Categories
- power supply
- TDK Lambda Power Supply
- Yamaha Power Supply
- Omron Power Supply
- Plus Power Supply
- Bestec Power Supply
- Sorensen Power Supply
- Antec Power Supply
- Meanwell Power Supply
- Weidmuller Power Supply
- Hipro Power Supply
- Sparkle Power Supply
- Lenovo Power Supply
- Zippy Power Supply
- Enermax Power Supply
- Agilent Power Supply
- Phihong Power Supply
- Liteon power supply
- Acble Power Supply
- Instek Power Supply
- Zalman Power Supply
- FSP Power Supply
- Aopen Power Supply
- Spellman Supply
- Delta Supply
- Cosel Supply
- Aj`s Power Source Supply
- Coolmax Supply
- MEAN WELL Power Supply
- SENDON Power Supply
- MGE Power Supply
- UPS Power Supply
- APC UPS Power Supply
- Riello UPS Power Supply
- EATON UPS Power Supply
- SANTAK UPS Power Supply
- Siemens UPS Power Supply
- Powerware UPS Power Supply
- OMRON UPS Power Supply
- Mitsubishi UPS Power Suppply
- DELTA Uninterruptible Power Supply
- EAST UPS Power Supply
- EMERSON UPS Power Supply
- Fuji UPS Power Supply
- EFFEKTA Uninterruptible Power Supply
- Gutor UPS Power Supply
- KELONG UPS Power Supply
- LADIS Uninterruptible Power Supply
- CBC UPS Power Supply
- Phoenix UPS Power Supply
- SVC Uninterruptible Power Supply
- Avaya UPS Power Supply
- NETCCA Uninterruptible Power Supply
- battery
- inverter
- Xantrex inverter
- Samlex inverter
- Schumacher inverter
- KACO inverter
- Wagan inverter
- AIMS inverter
- Victron inverter
- Targus inverter
- Whistler inverter
- Enphase inverter
- Satcon inverter
- Sima inverter
- Kensington inverter
- Exeltech inverter
- Stanley inverter
- ABB inverter
- SMA inverter
- Hyundai inverter
- Mastervolt inverter
- YAMAHA inverter
- Belkin inverter
- Microtek inverter
- Growatt inverter
- TDK inverter
- TOSHIBA inverter
- Su kam inverter
- Omnik inverter
- Ingeteam inverter
- Samil Power inverter
- Sungrow inverter
- Cobra inverter
- Power Bright inverter
- Bestek inverter
Contact Us
- A&S Power Supply Co.,Ltd
- Address:469, Xinsheng Road, Gaoxin District, Chengdu, Sichuan, China
- Tel:+86-28-65376776
- Fax:+86-28-86129221
- Email:inverter@electrical8.com
- Contact Person:Karina
Home / Products / UPS Power Supply / EFFEKTA Uninterruptible Power Supply / EFFEKTA AC large Uninterruptible Power Supply QUASAR II 30kVA
EFFEKTA AC large Uninterruptible Power Supply QUASAR II 30kVA
share
Description:
UPS-classification VFI-SS-111 in accordance with IEC 62040-3
Online double-conversion with sine-wave output
IGBT-rectifier
Comfortable front control panel incl. EPO
Interface for EPO remote control
Space-saving cable feeding from the bottom of the housing
Small dimensions (all models 910 x 390 x 900 mm)
EFFEKTA AC line-interactive MTD-series Uninterruptible Power Supply MTD 2000
Specification:Input Nominal load 230VACNominal input voltage 170~300VACInput frequency range 45~70Hz Auto SensingBoost starting value / shut-off 195.5VAC ± 2% / 205.5VAC ± 2%Buck starting value / shut-off 264.5VAC ± 2% / 254.5VAC ± 2%Output Output voltage Adjustable on LCD-display 220, 230, 240V
Specification:Input Nominal load 230VACNominal input voltage 170~300VACInput frequency range 45~70Hz Auto SensingBoost starting value / shut-off 195.5VAC ± 2% / 205.5VAC ± 2%Buck starting value / shut-off 264.5VAC ± 2% / 254.5VAC ± 2%Output Output voltage Adjustable on LCD-display 220, 230, 240V
EFFEKTA AC large Uninterruptible Power Supply MHD 15 kVA 3-1
Description:UPS-classification VFI-SS-111 (IEC 62040-3)Online Double-ConversionMultiple Microprocessor design baseDetachable control panel with LCDWide input voltage rangeOptionally parallel designDC start and automatic self-diagnostic functionCapacity of battery unlimited
Description:UPS-classification VFI-SS-111 (IEC 62040-3)Online Double-ConversionMultiple Microprocessor design baseDetachable control panel with LCDWide input voltage rangeOptionally parallel designDC start and automatic self-diagnostic functionCapacity of battery unlimited
EFFEKTA AC large Modular Uninterruptible Power Supply THOR T1 10-40kVA
Description:THOR Modular is EFFEKTA's new scalable online double-conversion UPS system with 3-phase in- and output. The system is available with a output power range of 10 up to 520kVA and can be equipped with modules from 10 up to 40kVA.Further including up to 4 of these systems can be operated in
Description:THOR Modular is EFFEKTA's new scalable online double-conversion UPS system with 3-phase in- and output. The system is available with a output power range of 10 up to 520kVA and can be equipped with modules from 10 up to 40kVA.Further including up to 4 of these systems can be operated in
EFFEKTA AC large Uninterruptible Power Supply TRITON M3 200kVA
Description:With the TRITON EFFEKTA® offers a modern, modular design, online double-conversion UPS with 3-phase input & output.The system has a modular construction. For simple commissioning, operation and maintenance of all controls, ports and the module are accessible from the front.
Description:With the TRITON EFFEKTA® offers a modern, modular design, online double-conversion UPS with 3-phase input & output.The system has a modular construction. For simple commissioning, operation and maintenance of all controls, ports and the module are accessible from the front.
EFFEKTA AC large Uninterruptible Power Supply TRITON M3 120kVA
Description:With the TRITON EFFEKTA® offers a modern, modular design, online double-conversion UPS with 3-phase input & output.The system has a modular construction. For simple commissioning, operation and maintenance of all controls, ports and the module are accessible from the front.
Description:With the TRITON EFFEKTA® offers a modern, modular design, online double-conversion UPS with 3-phase input & output.The system has a modular construction. For simple commissioning, operation and maintenance of all controls, ports and the module are accessible from the front.
EFFEKTA AC large Uninterruptible Power Supply Pegasus II 80kVA
Description:Online double-conversion UPS with 3-phase in- and output.. The system can be configured for parallel redundancy. There can be up to 8 units in parallel.The usage of IGBT rectifiers reduces the distortion of dependent mains. The current drain is pure sine wave.
Description:Online double-conversion UPS with 3-phase in- and output.. The system can be configured for parallel redundancy. There can be up to 8 units in parallel.The usage of IGBT rectifiers reduces the distortion of dependent mains. The current drain is pure sine wave.
EFFEKTA AC line-interactive MID-Series Uninterruptible Power Supply MID 1000
Specification:Input Nominal input voltage 230VACInput voltage range 162~290VACInput frequency range 50~60Hz Auto-SensingBoost starting value / shut-off 210.5VAC ± 2% / 213.5VAC ± 2%Buck starting value / shut-off 256.5VAC ± 2% / 250VAC ± 2%Output Output voltage 220, 230, 240VACPower factor 0.6Vol
Specification:Input Nominal input voltage 230VACInput voltage range 162~290VACInput frequency range 50~60Hz Auto-SensingBoost starting value / shut-off 210.5VAC ± 2% / 213.5VAC ± 2%Buck starting value / shut-off 256.5VAC ± 2% / 250VAC ± 2%Output Output voltage 220, 230, 240VACPower factor 0.6Vol
EFFEKTA AC large Uninterruptible Power Supply Pegasus II 125kVA
Description:Online double-conversion UPS with 3-phase in- and output.. The system can be configured for parallel redundancy. There can be up to 8 units in parallel.The usage of IGBT rectifiers reduces the distortion of dependent mains. The current drain is pure sine wave.
Description:Online double-conversion UPS with 3-phase in- and output.. The system can be configured for parallel redundancy. There can be up to 8 units in parallel.The usage of IGBT rectifiers reduces the distortion of dependent mains. The current drain is pure sine wave.
EFFEKTA AC large Modular Uninterruptible Power Supply THOR T1 30-300kVA
Description:THOR Modular is EFFEKTA's new scalable online double-conversion UPS system with 3-phase in- and output. The system is available with a output power range of 10 up to 520kVA and can be equipped with modules from 10 up to 40kVA.Further including up to 4 of these systems can be operated in
Description:THOR Modular is EFFEKTA's new scalable online double-conversion UPS system with 3-phase in- and output. The system is available with a output power range of 10 up to 520kVA and can be equipped with modules from 10 up to 40kVA.Further including up to 4 of these systems can be operated in
EFFEKTA AC line-interactive MTD-RT-Series Uninterruptible Power Supply MTD 2000 RT
Specification:Nominal input voltage / voltage range 230VAC / 161~276VACInput frequency range 50/60Hz normal mode / 40-70Hz generator modeBoost threshold 207VAC ± 4% / 215VAC ± 4% (setup 230VAC wide range)Output voltage 220, 230, 240VACVoltage tolerance (battery mode) ± 5% RMSTHD(i) linear load <
Specification:Nominal input voltage / voltage range 230VAC / 161~276VACInput frequency range 50/60Hz normal mode / 40-70Hz generator modeBoost threshold 207VAC ± 4% / 215VAC ± 4% (setup 230VAC wide range)Output voltage 220, 230, 240VACVoltage tolerance (battery mode) ± 5% RMSTHD(i) linear load <
Hot Products