MGE Galaxy 3500 UPS G35T10KH3B4S

MGE Galaxy 3500 UPS G35T10KH3B4S
share

Specifications:
Output
Output Power Capacity 8000 Watts / 10 kVA
Max Configurable Power 8000 Watts / 10 kVA
Nominal Output Voltage 400V 3PH
Output Frequency (sync to mains) 47 - 53 Hz for 50 Hz nominal
Output Connections
(1) Hard Wire 4-wire (3PH + G)
(1) Hard Wire 5-wire (3PH + N + G)
Efficiency at Half Load 95.2%
Input
Nominal Input Voltage 400V 3PH
Input Frequency 40 - 70 Hz (auto sensing)
Input Connections
Hard Wire 5-wire (3PH + N + G)

MGE Galaxy 3500 UPS G35T40KHS
MGE Galaxy 3500 UPS G35T40KHS
Specifications:OutputOutput Power Capacity 32 kW / 40 kVAMax Configurable Power 32 kW / 40 kVANominal Output Voltage 400V 3PHEfficiency at Full Load 95.8%Output Connections(1) Hard Wire 4-wire (3PH + G) (1) Hard Wire 5-wire (3PH + N + G) Efficiency at Half Load 95.5%InputNominal Input Voltage 400V 3
MGE Galaxy 6000 G6TAUX200
MGE Galaxy 6000 G6TAUX200
Descriptions:MGE Galaxy 6000 Auxiliaries 200 kVAG6TAUX200250-500kVA Robust 3 phase power protection withadaptability to meet the unique requirements of medium to large data centers, buildings and criticalindustrial processesIncludes: Installation guide, User Manual
MGE Galaxy 7000 G7TAB
MGE Galaxy 7000 G7TAB
Description:UPS matching, empty battery cubicles (IP 20 or IP32), aesthetic design ready to accommodate any kind of sealed lead acid batteries
MGE Galaxy 7000 G7TUPS300
MGE Galaxy 7000 G7TUPS300
Description:A high-adaptability, 3-phase UPS that meets the unique requirements of medium to large data centers, industry, buildings, and mission-critical environments. This UPS includes ECO Mode, with cost-saving energy efficiency, and SPoT operation mode,which increases on-site test capability wit
MGE Galaxy PW GWTUPS200
MGE Galaxy PW GWTUPS200
Specifications:OutputOutput Power Capacity 160 kW / 200 kVAMax Configurable Power 160 kW / 200 kVANominal Output Voltage 208V 3PH, 480V 3PH, 600V 3PHInputNominal Input Voltage 208V 3PH, 480V 3PH, 600V 3PHInput Frequency 45 - 65 HzInput ConnectionsHard Wire 4-wire (3PH + N) Hard Wire 5-wire (3PH + N
MGE Galaxy 5000 UPS G5TUPS80
MGE Galaxy 5000 UPS G5TUPS80
Specifications:OutputOutput Power Capacity 72 kW / 80 kVAMax Configurable Power 72 kW / 80 kVANominal Output Voltage 400V 3PH, 480V 3PH, 600V 3PHEfficiency at Full Load 92.8%Output Voltage Distortion Less than 2%Crest Factor 3 : 1Output Connections(1) Hard Wire 4-wire (3PH + G) (1) Hard Wire 5-wire
MGE Galaxy 3500 UPS 35T30K3I3B4S
MGE Galaxy 3500 UPS 35T30K3I3B4S
Specifications:OutputOutput Power Capacity 24 kW / 30 kVAMax Configurable Power 24 kW / 30 kVANominal Output Voltage 230VEfficiency at Full Load 95.3%Output Voltage Distortion Less than 5%Other Output Voltages 220, 240Output Connections(1) Hard Wire 3-wire (H N + G) Required Output Current Protectio
MGE Galaxy 9000 G9TUPS800
MGE Galaxy 9000 G9TUPS800
Specifications:OutputOutput Power Capacity 720 kW / 800 kVAMax Configurable Power 720 kW / 800 kVANominal Output Voltage 400V 3PHOutput Voltage Note Configurable for 380 : 400 or 415 V 3 Phase nominal output voltageEfficiency at Full Load 93.5%InputNominal Input Voltage 400V 3PHInput Frequency 45 -
MGE Galaxy 5500 G55TUPSU120HS
MGE Galaxy 5500 G55TUPSU120HS
Specifications:OutputOutput Power Capacity 108 kW / 120 kVAMax Configurable Power 108 kW / 120 kVANominal Output Voltage 400V 3PHInputNominal Input Voltage 400V 3PHInput Frequency 45 - 65 HzInput ConnectionsHard Wire 4-wire (3PH + G) Hard Wire 4-wire (3PH + N) Input voltage range for main operations
MGE Galaxy 3500 UPS G35T20KHSG
MGE Galaxy 3500 UPS G35T20KHSG
Specifications:OutputOutput Power Capacity 16 kW / 20 kVAMax Configurable Power 16 kW / 20 kVANominal Output Voltage 400V 3PHEfficiency at Full Load 95.5%Output Voltage Distortion Less than 5%Output Connections(1) Hard Wire 4-wire (3PH + G) (1) Hard Wire 5-wire (3PH + N + G) Efficiency at Half Load