Home / Products / UPS Power Supply / Mitsubishi UPS Power Suppply / Mitsubishi 9700 Series UPS 150KVA/120KW

Mitsubishi 9700 Series UPS 150KVA/120KW

Mitsubishi 9700 Series UPS 150KVA/120KW
share

SPECIFICATION:
AC INPUT CHARACTERISTICS
Configuration 3 phase, 3 wire
Voltage 208V +10% ~ -15%
Input Power Factor 0.98 Typical
Frequency 60 Hz ±5%
Reflected Current THD 3% max. at 100% load; 5% max. at 50% load
STATIC BYPASS INPUT
Configuration 3 phase, 3 or 4 wire
Voltage 120/208V ±10%
Frequency 60 Hz (±3% Tracking window)

Mitsubishi 9700 Series UPS 150KVA/120KW
Mitsubishi 9700 Series UPS 150KVA/120KW
SPECIFICATION:AC INPUT CHARACTERISTICSConfiguration 3 phase, 3 wireVoltage 208V +10% ~ -15%Input Power Factor 0.98 TypicalFrequency 60 Hz ±5%Reflected Current THD 3% max. at 100% load; 5% max. at 50% loadSTATIC BYPASS INPUTConfiguration 3 phase, 3 or 4 wireVoltage 120/208V ±10%Frequency 60 Hz (±3
Mitsubishi 7011A Series UPS 12KVA
Mitsubishi 7011A Series UPS 12KVA
Description:Design: On-Line Double Conversion with Extra Wide Input Voltage and Frequency WindowPower Rating: 6, 8, 10, 12 kVAVoltage Options: Input: 120/208 or 120/240 VAC Single Phase Output: 120/208 or 120/240 VAC Single Phase
Mitsubishi 2033A Series UPS 40KVA
Mitsubishi 2033A Series UPS 40KVA
Specification:AC Input Rating +10%~ −15% Power: Rated kVA at 1:1 ratioTHD: 3% max. (100% load) 6% max. (50% load)3-phase, 3-wire, plus groundFrequency: 60Hz (±5%)AC Output Rating3-phase, 4-wire208 / 480 / 600 VACFrequency: 60Hz Voltage accuracy: ±1%
Mitsubishi 1100A Series UPS 30KVA
Mitsubishi 1100A Series UPS 30KVA
Description:Design: Double Conversion On-Line TopologyPower Ratings: 10, 20, 30, 40, 50 kVAVoltage Options: Input: 208/120V; Output: 208/120VDesign Features:>93% EfficiencyAvailable for All ModelsCompact Design: 19.7"W x 27"D x 55.1"H 0.9 Power FactorCable Entrance on Bottom, Side and RearTwo (2) Ye
Mitsubishi 9800AD Series UPS 225KVA/180KW
Mitsubishi 9800AD Series UPS 225KVA/180KW
Specification:AC Input Rating-15% ~ +15%Power: Rated kVA at 1:1.1 ratio480 VAC (600 VAC usinginput transformer)THD (reflected current):6% typical (100% load) 9% typical (50% load)3-phase, 4-wire, plus ground(Bypass: 4-wire, Rectifier: 3-wire)Frequency: 60Hz (±5%)480Y/277 VAC
Mitsubishi 9900A Series UPS 225kVA
Mitsubishi 9900A Series UPS 225kVA
Description:The 9900 Series UPS incorporates the newest IGBT technology in an UPS. This IGBT technology is used in the rectifier/converter, DC/DC chopper, and the inverter sections of the UPS. By using this new IGBT technology the 9900's double-conversion topology provides an AC/DC/AC efficiency of
Mitsubishi 2033A Series UPS 75KVA
Mitsubishi 2033A Series UPS 75KVA
Specification:AC Input Rating +10%~ −15% Power: Rated kVA at 1:1 ratioTHD: 3% max. (100% load) 6% max. (50% load)3-phase, 3-wire, plus groundFrequency: 60Hz (±5%)AC Output Rating3-phase, 4-wire208 / 480 / 600 VACFrequency: 60Hz Voltage accuracy: ±1%
Mitsubishi 2033A Series UPS 30KVA
Mitsubishi 2033A Series UPS 30KVA
Specification:AC Input Rating +10%~ −15% Power: Rated kVA at 1:1 ratioTHD: 3% max. (100% load) 6% max. (50% load)3-phase, 3-wire, plus groundFrequency: 60Hz (±5%)AC Output Rating3-phase, 4-wire208 / 480 / 600 VACFrequency: 60Hz Voltage accuracy: ±1%
Mitsubishi 9900A Series UPS 100kVA
Mitsubishi 9900A Series UPS 100kVA
Description:The 9900 Series UPS incorporates the newest IGBT technology in an UPS. This IGBT technology is used in the rectifier/converter, DC/DC chopper, and the inverter sections of the UPS. By using this new IGBT technology the 9900's double-conversion topology provides an AC/DC/AC efficiency of
Mitsubishi 9700 Series UPS 225KVA/180KW
Mitsubishi 9700 Series UPS 225KVA/180KW
SPECIFICATION:AC INPUT CHARACTERISTICSConfiguration 3 phase, 3 wireVoltage 208V +10% ~ -15%Input Power Factor 0.98 TypicalFrequency 60 Hz ±5%Reflected Current THD 3% max. at 100% load; 5% max. at 50% loadSTATIC BYPASS INPUTConfiguration 3 phase, 3 or 4 wireVoltage 120/208V ±10%Frequency 60 Hz (±3