Specification:
Rated power capacity 2000VA 3000VA
DC input
Rated DC voltage(Vdc)48V/220V
DC input voltage(Vdc)48V/220V -18% ~48V/220V +25%
Input reflected noice When Input voltage and load current are rated value,<10%
AC input
Input voltage 220V-25% ~ 220V+20%
Iutput frequency 50Hz±10%
AC output
Out voltage(Vac)220V±2%
output frequency(Hz)50Hz±0.1%
Rated output current(A)6.3A 9.5 A
Input power factor(PF)
0.8

NETCCA High Frequency Uninterruptible Power Supply PV1103S
NETCCA High Frequency Uninterruptible Power Supply PV1103S
Specification:InputCurrent 50AVoltage 176~276VACWire Single phase with two lines+ ground wireFrequency46~54HzOutputCurrent 45AVoltage 220*(1±1%)VACFrequency Synchronized with the power grid (Main power mode); 50*(1±0.1%)Hz(Battery mode)Waveform Sine wave formOverload 105%~130% transfer to
NETCCA Rackmount Uninterruptible Power Supply 3U
NETCCA Rackmount Uninterruptible Power Supply 3U
Specification:Rated power capacity 2000VA 3000VADC inputRated DC voltage(Vdc)48V/220VDC input voltage(Vdc)48V/220V -18% ~48V/220V +25%Input reflected noice When Input voltage and load current are rated value,<10%AC inputInput voltage 220V-25% ~ 220V+20%Iutput frequency 50Hz±10%AC outp
NETCCA High Frequency Uninterruptible Power Supply PV1063
NETCCA High Frequency Uninterruptible Power Supply PV1063
Specification:InputCurrent 31AVoltage 176~276VACWire Single phase with two lines+ ground wireFrequency46~54HzOutputCurrent 27AVoltage 220*(1±1%)VACFrequency Synchronized with the power grid (Main power mode); 50*(1±0.1%)Hz(Battery mode)Waveform Sine wave formOverload 105%~130% transfer to
NETCCA Normal frequency Uninterruptible Power Supply 2-400K
NETCCA Normal frequency Uninterruptible Power Supply 2-400K
Description:NETCCA Normol UPS can supply the best power source for the loaded equipments in a more steady way. Also, they possess stronger anti-concussion and anti-overload ability that can adapt to the toughest electric environment.
NETCCA Offline PCH Series Uninterruptible Power Supply PCH500
NETCCA Offline PCH Series Uninterruptible Power Supply PCH500
Specification:Using rate capacity 300WInput Voltage 170~260VacInput Frequency 50Hz±5%Output Voltage(battery pattern) 220±10%VacOutput Frequency 82Hz±2%Output wave square wave
NETCCA High Frequency Uninterruptible Power Supply PV1103S
NETCCA High Frequency Uninterruptible Power Supply PV1103S
Specification:InputCurrent 50AVoltage 176~276VACWire Single phase with two lines+ ground wireFrequency46~54HzOutputCurrent 45AVoltage 220*(1±1%)VACFrequency Synchronized with the power grid (Main power mode); 50*(1±0.1%)Hz(Battery mode)Waveform Sine wave formOverload 105%~130% transfer to
NETCCA Rackmount Uninterruptible Power Supply 1U
NETCCA Rackmount Uninterruptible Power Supply 1U
Specification:Input Voltage 165~265VacInput Frequency 45Hz-65 HzOutput Voltage(battery pattern) 220±10%VacOutput Frequency 50Hz±0.2%Output wave true sine waveTransfer time 2-4ms
NETCCA Elevator Uninterruptible Power Supply BE6K-DT
NETCCA Elevator Uninterruptible Power Supply BE6K-DT
Description:DT-UPS is an elevator emergence device avoiding human assident in case of a power failure of elevator. DT-UPS can be equipped with all kinds of VVVF elevators. As an automatic emergence rescuse device, when elevator stops running because of interruption of mains supply or other reasons,
NETCCA Rackmount Uninterruptible Power Supply 500VA-3000VA
NETCCA Rackmount Uninterruptible Power Supply 500VA-3000VA
Specification:19/21 inch Rack-mount Low frequency and double conversion line-interactive technology Fully digitized microprocessor control Wide input voltage range Advanced PFC technology Self-testing when UPS startup Advanced battery management Automatic battery charge in UPS off mode(2000VA
NETCCA Smart online Uninterruptible Power Supply sine1000VA
NETCCA Smart online Uninterruptible Power Supply sine1000VA
Specificatio:Using rate capacity 700WOutput votage 220V(adjustable)Stablize voltage range 190V~240VOutput friquence 47 - 53 Hz for 50 Hz nominal,57 - 63 Hz for 60 Hz nominalWaveform True sine waveOutput socker/line Guobiao/ IEC 320 C13(optional)Rated input voltage 220VInput frequence 0/60 Hz