Omron Power Supply S8EX Series S8EX-P15005LC

Omron Power Supply S8EX Series S8EX-P15005LC
share

With chassis and cover , Input 100 to 240 VAC , 150W , Output 5V 30A
Power rating 150 W
Efficiency 84% Min. ï¼ˆAt 100 VAC input)87% Min. ï¼ˆAt 200 VAC input)
Rated input voltage 100 to 240 VAC
Allowable-input voltage variable range 85 to 264 VAC120 to 370 VDC
Note at DC input The range for compliance with EC Directives and safety standards (UL, EN, etc.) is 100 to 240 VAC (85 to 264 VAC).
Frequency 50/60 Hz (47 to 63 Hz )
Rated input current 1.9 A TYP. ï¼ˆAt 100 VAC input)0.95 A TYP. ï¼ˆAt 200 VAC input)
Power factor 0.9 Min. (At rated input, 100% load)
Harmonic Current EN61000-3-2
Leakage current 0.5 mA Max. (At 100 VAC input)1 mA Max. (At 200 VAC input)
Inrush current 14.1 A TYP. ï¼ˆAt 100 VAC input (For cold start at 25 CEL))28.3 A TYP. ï¼ˆAt 200 VAC input (For cold start at 25 CEL))
Rated output voltage 5 VDC
Output voltage variable range -10 to +10% (With V. ADJ)(If the output voltage adjuster (V. ADJ) is turned, the voltage will increase by more than the allowable voltage range. When adjusting the output voltage, confirm the actual output voltage from the Power Supply and be sure that load is not damaged.)
Ripple 150 mV Max.
Static input variation influence 0.5% Max. (At 85 to 264 VAC input, 100% load)
Static load variation influence 2% Max. (At rated input, 0 to 100% load)
Ambient temperature variation influence 0.05 %/CEL Max.
Rated output current 30 A
Start up time 450 ms TYP. ï¼ˆ100 VAC input)
Hold time 25 ms TYP. ï¼ˆ100 VAC input)
Overload protection 105% to 160% of the rated output currentVoltage drop, Intermittent operation, Automatic reset
Overvoltage protection Operated at 130% Min. of the rated output voltage, Shut-offResetting: Reset the power by turning it back (OFF time: at least 3 min)
Power factor improvement function Yes
Parallel operation No (However, backup operation is possible; external diodes required.)
Series operation Yes (Up to 2 Power Supplies)
Applicable standard (UL) Standard No.: UL UR: UL60950-1 (Recognition)
Applicable standard (CSA) Standard No.: cUR: CSA C22.2 No.60950-1
Applicable standard (EN) Standard No.: EN50178, EN60950-1
Applicable standard (EC Directive (EMI)) Emission Enclosure: Conforms to EN55011 Group 1 Class BEmission AC mains: Conforms to EN55011 Group 1 Class B
Applicable standard(SEMI) F47-0706 (200 VAC input)
Ambient temperature Operating: -10 to 70 CELStorage: -25 to 75 CEL(with no icing or condensation)
Ambient humidity Operating: 25 to 85% RHStorage: 25 to 90% RH(With no icing or condensation)
Dielectric strength Between all inputs and all outputs: 3 kVAC for 1 min (Detection current: 20 mA)Between all inputs and PE terminals: 2 kVAC for 1 min (Detection current: 20 mA)Between all outputs and PE terminals: 1 kVAC for 1 min (Detection current: 20 mA)
Insulation resistance Between all outputs and all inputs/ PE terminals: 100 MOhm Min.
Vibration resistance 10 to 55 Hz, 19.6 m/s**2 (2 G) in each 3 directions for 1 hour
Shock resistance 196.1 m/s**2, in each 6 directions 3 times
Heat radiation Natural air-cooling
Construction With chassis and cover

Omron Power Supply S8VS Series S8VS-18024AP-F
Omron Power Supply S8VS Series S8VS-18024AP-F
Maintenance Forecast Monitor Type , Input 100 to 240 VAC , 180 W , Output 24 V 7.5 A , With Undervoltage Alarm (Ttransistor (Sourcing))Power rating 180 WEfficiency 85%&nb
Omron Power Supply S8VS Series S8VS-09024S
Omron Power Supply S8VS Series S8VS-09024S
Standard Model , Input 100 to 240 VAC , 90 W , Output 24 V 3.75 APower rating 90 WEfficiency 83% TYP. ï¼ˆAt 100 VAC input)84% TYP. ï¼ˆAt 200 VAC input)Rat
Omron Power Supply S8JX Switch Mode Power S8JX-P60005C
Omron Power Supply S8JX Switch Mode Power S8JX-P60005C
Covered type , Input 100 to 240 VAC , 600W , Output 5V 120A , Front-mounting typePower rating 600 WEfficiency 76% Min.Rated input voltage 100 to 240 VACAllowable-input voltage
Omron Power Supply S8EX Series S8EX-BP15048L
Omron Power Supply S8EX Series S8EX-BP15048L
With chassis , Input 100 to 240 VAC , 150W , Output 48V 3.2APower rating 150 WEfficiency 85% Min. ï¼ˆAt 100 VAC input)88% Min. ï¼ˆAt 200 VAC input)Rated 
Omron Power Supply S8VS Series S8VS-09024A-F
Omron Power Supply S8VS Series S8VS-09024A-F
Total Run Time Monitor , Input 100 to 240 VAC , 90 W , Output 24 V 3.75 APower rating 90 WEfficiency 83% TYP. ï¼ˆAt 100 VAC input)85% TYP. ï¼ˆAt 200 
Omron Power Supply S82S S82S-7712
Omron Power Supply S82S S82S-7712
Input 12 to 24 VDC , 7.5 W , Output 12 V 0.6 APower rating 7.5 WEfficiency 69% Min.Rated input voltage 12 to 24 VDCAllowable-input voltage variable range 10.2 to 27.6&nbs
Omron Power Supply S8VS Series S8VS-24024BP
Omron Power Supply S8VS Series S8VS-24024BP
Total Run Time Monitor , Input 100 to 240 VAC , 240 W , Output 24 V 10 A , With Undervoltage Alarm (Ttransistor (Sourcing))Power rating 240 WEfficiency 85% TYP. 
Omron S8JX Switch Mode Power S8JX-G03515D
Omron S8JX Switch Mode Power S8JX-G03515D
Open-Frame Type , Input 100 to 240 VAC , 35W , Output 15V 2.4A , DIN Rail mounting typeAs of November 15, 2012Power rating 35 WEfficiency 73% Min.Rated input voltage
Omron Power Supply S8EX Series S8EX-BP15012LC
Omron Power Supply S8EX Series S8EX-BP15012LC
With chassis and cover , Input 100 to 240 VAC , 150W , Output 12V 12.5APower rating 150 WEfficiency 83% Min. ï¼ˆAt 100 VAC input)86% Min. ï¼ˆAt 200 VAC i
Omron Power Supply S8VS Series S8VS-48024A
Omron Power Supply S8VS Series S8VS-48024A
Maintenance Forecast Monitor Type , Input 100 to 240 VAC , 480 W , Output 24 V 20 APower rating 480 WEfficiency 85% TYP. ï¼ˆAt 100 VAC input)89% TYP. ï¼ˆAt&nbs