Open type , Input 100 to 240 VAC , 150W , Output 24V 6.3A
Power rating 150 W
Efficiency 84% Min. Ã¯Â¼Ë†At 100 VAC input)87% Min. Ã¯Â¼Ë†At 200 VAC input)
Rated input voltage 100 to 240 VAC
Allowable-input voltage variable range 85 to 264 VAC120 to 370 VDC
Note at DC input The range for compliance with EC Directives and safety standards (UL, EN, etc.) is 100 to 240 VAC (85 to 264 VAC).
Frequency 50/60 Hz (47 to 63 Hz )
Rated input current 1.9 A TYP. Ã¯Â¼Ë†At 100 VAC input)0.95 A TYP. Ã¯Â¼Ë†At 200 VAC input)
Power factor 0.9 Min. (At rated input, 100% load)
Harmonic Current EN61000-3-2
Leakage current 0.5 mA Max. (At 100 VAC input)1 mA Max. (At 200 VAC input)
Inrush current 14.1 A TYP. Ã¯Â¼Ë†At 100 VAC input (For cold start at 25 CEL))28.3 A TYP. Ã¯Â¼Ë†At 200 VAC input (For cold start at 25 CEL))
Rated output voltage 24 VDC
Output voltage variable range -10 to +10% (With V. ADJ)(If the output voltage adjuster (V. ADJ) is turned, the voltage will increase by more than the allowable voltage range. When adjusting the output voltage, confirm the actual output voltage from the Power Supply and be sure that load is not damaged.)
Ripple 480 mV Max.
Static input variation influence 0.5% Max. (At 85 to 264 VAC input, 100% load)
Static load variation influence 1.5% Max. (At rated input, 0 to 100% load)
Ambient temperature variation influence 0.05 %/CEL Max.
Rated output current 6.3 A , 12.6 A (Peak current)
Start up time 660 ms TYP. Ã¯Â¼Ë†100 VAC input)
Hold time 21 ms TYP. Ã¯Â¼Ë†100 VAC input)
Overload protection 100% to 110% of power boost for output currenttVoltage drop, Intermittent operation, Automatic reset
Overvoltage protection Operated at 130% Min. of the rated output voltage, Shut-offResetting: Reset the power by turning it back (OFF time: at least 3 min)
Power factor improvement function Yes
Parallel operation No (However, backup operation is possible; external diodes required.)
Series operation Yes (Up to 2 Power Supplies)
Applicable standard (UL) Standard No.: UL UR: UL60950-1 (Recognition)
Applicable standard (CSA) Standard No.: cUR: CSA C22.2 No.60950-1
Applicable standard (EN) Standard No.: EN50178, EN60950-1
Applicable standard (EC Directive (EMI)) Emission Enclosure: Conforms to EN55011 Group 1 Class BEmission AC mains: Conforms to EN55011 Group 1 Class B
Applicable standard(SEMI) F47-0706 (200 VAC input)
Ambient temperature Operating: -10 to 70 CELStorage: -25 to 75 CEL(with no icing or condensation)
Ambient humidity Operating: 25 to 85% RHStorage: 25 to 90% RH(With no icing or condensation)
Dielectric strength Between all inputs and all outputs: 3 kVAC for 1 min (Detection current: 20 mA)Between all inputs and PE terminals: 2 kVAC for 1 min (Detection current: 20 mA)Between all outputs and PE terminals: 1 kVAC for 1 min (Detection current: 20 mA)
Insulation resistance Between all outputs and all inputs/ PE terminals: 100 MOhm Min.
Vibration resistance 10 to 55 Hz, 19.6 m/s**2 (2 G) in each 3 directions for 1 hour
Shock resistance 196.1 m/s**2, in each 6 directions 3 times
Heat radiation Natural air-cooling
Construction Open-frame type
Weight 315 g Max.

Omron Power Supply S8TX Series S8TS-06024
Omron Power Supply S8TX Series S8TS-06024
Basic Block , Screw Terminal , Input 100 to 240 VAC , Output 24 V 2.5 APower rating 60 WEfficiency 80% TYP. Ã¯Â¼Ë†At rated input, 100% load)Rated input voltage 100 t
Omron S8JX Switch Mode Power S8JX-G01512
Omron S8JX Switch Mode Power S8JX-G01512
Open-Frame Type , Input 100 to 240 VAC , 15W , Output 12V 1.3A , Front-mounting typePower rating 15 WEfficiency 68% Min.Rated input voltage 100 to 240 VACAllowable-input volta
Omron Power Supply S8EX Series S8EX-N03015L
Omron Power Supply S8EX Series S8EX-N03015L
With chassis and cover , Input 100 to 240 VAC , 30W , Output 15V 2APower rating 30 WEfficiency 83% Min. Ã¯Â¼Ë†At 100 VAC input)83% Min. Ã¯Â¼Ë†At 200 VAC inputÃ
Omron Power Supply S8VM Series S8VM-01524CD
Omron Power Supply S8VM Series S8VM-01524CD
Standard Type , Covered Type , DIN Rail Mounting Bracket Type , Input 100 to 240 VAC , 15 W , Output 24 V 0.65 APower rating 15 WEfficiency 80% Min.Rated i
Omron Power Supply S8VS Series S8VS-48024A
Omron Power Supply S8VS Series S8VS-48024A
Maintenance Forecast Monitor Type , Input 100 to 240 VAC , 480 W , Output 24 V 20 APower rating 480 WEfficiency 85% TYP. Ã¯Â¼Ë†At 100 VAC input)89% TYP. Ã¯Â¼Ë†At&nbs
Omron Power Supply S8VS Series S8VS-12024
Omron Power Supply S8VS Series S8VS-12024
Total Run Time Monitor , Input 100 to 240 VAC , 60 W , Output 24 V 2.5 APower rating 60 WEfficiency 83% TYP. Ã¯Â¼Ë†At 100 VAC input)85% TYP. Ã¯Â¼Ë†At 200 V
Omron Power Supply S8EX Series S8EX-BP15048
Omron Power Supply S8EX Series S8EX-BP15048
Open type , Input 100 to 240 VAC , 150W , Output 48V 3.2APower rating 150 WEfficiency 85% Min. Ã¯Â¼Ë†At 100 VAC input)88% Min. Ã¯Â¼Ë†At 200 VAC input)Rated in
Omron Power Supply S8VM Series S8VM-03005C
Omron Power Supply S8VM Series S8VM-03005C
Standard Type , Covered Type , Bottom Mounting Type , Input 100 to 240 VAC , 30 W , Output 5 V 6 APower rating 30 WEfficiency 75% Min.Rated input voltage 100&nb
Omron Power Supply S8JX Switch Mode Power S8JX-P15048C
Omron Power Supply S8JX Switch Mode Power S8JX-P15048C
Covered type , Input 100 to 240 VAC , 150W , Output 48V 3.3A , Front-mounting typePower rating 150 WEfficiency 82% Min.Rated input voltage 100 to 240 VACAllowable-input voltag
Omron Power Supply S8VS Series S8VS-01512
Omron Power Supply S8VS Series S8VS-01512
Total Run Time Monitor , Input 100 to 240 VAC , 120 W , Output 24 V 5 A , With Undervoltage Alarm (Ttransistor (Sourcing))Power rating 120 WEfficiency 83% TYP.