Cart()
 
 
Categories
Contact Us
  • A&S Power Supply Co.,Ltd
  • Address:469, Xinsheng Road, Gaoxin District, Chengdu, Sichuan, China
  • Tel:+86-28-65376776
  • Fax:+86-28-86129221
  • Email:inverter@electrical8.com
  • Contact Person:Karina
Home / Products / power supply / Omron Power Supply / S8EX / Omron Power Supply S8EX Series S8EX-BP15024

Omron Power Supply S8EX Series S8EX-BP15024

Omron Power Supply S8EX Series S8EX-BP15024
share

Open type , Input 100 to 240 VAC , 150W , Output 24V 6.3A
Power rating 150 W
Efficiency 84% Min. ï¼ˆAt 100 VAC input)87% Min. ï¼ˆAt 200 VAC input)
Rated input voltage 100 to 240 VAC
Allowable-input voltage variable range 85 to 264 VAC120 to 370 VDC
Note at DC input The range for compliance with EC Directives and safety standards (UL, EN, etc.) is 100 to 240 VAC (85 to 264 VAC).
Frequency 50/60 Hz (47 to 63 Hz )
Rated input current 1.9 A TYP. ï¼ˆAt 100 VAC input)0.95 A TYP. ï¼ˆAt 200 VAC input)
Power factor 0.9 Min. (At rated input, 100% load)
Harmonic Current EN61000-3-2
Leakage current 0.5 mA Max. (At 100 VAC input)1 mA Max. (At 200 VAC input)
Inrush current 14.1 A TYP. ï¼ˆAt 100 VAC input (For cold start at 25 CEL))28.3 A TYP. ï¼ˆAt 200 VAC input (For cold start at 25 CEL))
Rated output voltage 24 VDC
Output voltage variable range -10 to +10% (With V. ADJ)(If the output voltage adjuster (V. ADJ) is turned, the voltage will increase by more than the allowable voltage range. When adjusting the output voltage, confirm the actual output voltage from the Power Supply and be sure that load is not damaged.)
Ripple 480 mV Max.
Static input variation influence 0.5% Max. (At 85 to 264 VAC input, 100% load)
Static load variation influence 1.5% Max. (At rated input, 0 to 100% load)
Ambient temperature variation influence 0.05 %/CEL Max.
Rated output current 6.3 A , 12.6 A (Peak current)
Start up time 660 ms TYP. ï¼ˆ100 VAC input)
Hold time 21 ms TYP. ï¼ˆ100 VAC input)
Overload protection 100% to 110% of power boost for output currenttVoltage drop, Intermittent operation, Automatic reset
Overvoltage protection Operated at 130% Min. of the rated output voltage, Shut-offResetting: Reset the power by turning it back (OFF time: at least 3 min)
Power factor improvement function Yes
Parallel operation No (However, backup operation is possible; external diodes required.)
Series operation Yes (Up to 2 Power Supplies)
Applicable standard (UL) Standard No.: UL UR: UL60950-1 (Recognition)
Applicable standard (CSA) Standard No.: cUR: CSA C22.2 No.60950-1
Applicable standard (EN) Standard No.: EN50178, EN60950-1
Applicable standard (EC Directive (EMI)) Emission Enclosure: Conforms to EN55011 Group 1 Class BEmission AC mains: Conforms to EN55011 Group 1 Class B
Applicable standard(SEMI) F47-0706 (200 VAC input)
Ambient temperature Operating: -10 to 70 CELStorage: -25 to 75 CEL(with no icing or condensation)
Ambient humidity Operating: 25 to 85% RHStorage: 25 to 90% RH(With no icing or condensation)
Dielectric strength Between all inputs and all outputs: 3 kVAC for 1 min (Detection current: 20 mA)Between all inputs and PE terminals: 2 kVAC for 1 min (Detection current: 20 mA)Between all outputs and PE terminals: 1 kVAC for 1 min (Detection current: 20 mA)
Insulation resistance Between all outputs and all inputs/ PE terminals: 100 MOhm Min.
Vibration resistance 10 to 55 Hz, 19.6 m/s**2 (2 G) in each 3 directions for 1 hour
Shock resistance 196.1 m/s**2, in each 6 directions 3 times
Heat radiation Natural air-cooling
Construction Open-frame type
Weight 315 g Max.

Omron Power Supply S8EX Series S8EX-N03012LC
Omron Power Supply S8EX Series S8EX-N03012LC
With chassis and cover , Input 100 to 240 VAC , 30W , Output 12V 2.5APower rating 30 WEfficiency 82% Min. ï¼ˆAt 100 VAC input)83% Min. ï¼ˆAt 200 VAC inpu
Omron Power Supply S8VM Series S8VM-10015
Omron Power Supply S8VM Series S8VM-10015
Standard Type , Open-Frame Type , Bottom Mounting Type , Input 100 to 240 VAC , 100 W , Output 15 V 7 APower rating 100 WEfficiency 81% Min.Rated input voltage
Omron Power Supply S8VS Series S8VS-24024BE-F
Omron Power Supply S8VS Series S8VS-24024BE-F
TotalPower rating 240 WEfficiency 85% TYP. ï¼ˆAt 100 VAC input)88% TYP. ï¼ˆAt 200 VAC input)Rated input voltage 100 to 240 VACAllowable-input voltage variable range 85 to 264 VAC8
Omron S8JX Switch Mode Power S8JX-P05048C
Omron S8JX Switch Mode Power S8JX-P05048C
Covered type , Input 100 to 240 VAC , 50W , Output 48V 1.1A , Front-mounting typePower rating 50 WEfficiency 80% Min.Rated input voltage 100 to 240 VACAllowable-input voltage&
Omron Power Supply S8VS Series S8VS-18024
Omron Power Supply S8VS Series S8VS-18024
Standard Model , Input 100 to 240 VAC , 180 W , Output 24 V 7.5 APower rating 180 WEfficiency 85% TYP. ï¼ˆAt 100 VAC input)88% TYP. ï¼ˆAt 200 VAC input)Ra
Omron Power Supply S8JX Switch Mode Power S8JX-P60005C
Omron Power Supply S8JX Switch Mode Power S8JX-P60005C
Covered type , Input 100 to 240 VAC , 600W , Output 5V 120A , Front-mounting typePower rating 600 WEfficiency 76% Min.Rated input voltage 100 to 240 VACAllowable-input voltage
Omron S8JX Switch Mode Power S8JX-G05024
Omron S8JX Switch Mode Power S8JX-G05024
Open-Frame Type , Input 100 to 240 VAC , 50W , Output 24V 2.1A , Front-mounting typePower rating 50 WEfficiency 83% Min.Rated input voltage 100 to 240 VACAllowable-input volta
Omron Power Supply S8EX Series S8EX-BP10024LC
Omron Power Supply S8EX Series S8EX-BP10024LC
With chassis and cover , Input 100 to 240 VAC , 100W , Output 24V 4.3APower rating 100 WEfficiency 84% Min. ï¼ˆAt 100 VAC input)86% Min. ï¼ˆAt 200 VAC in
Omron Power Supply S8JX Switch Mode Power S8JX-P30048CD
Omron Power Supply S8JX Switch Mode Power S8JX-P30048CD
Covered type , Input 100 to 240 VAC , 300W , Output 48V 7A , DIN Rail mounting typePower rating 300 WEfficiency 78% Min.Rated input voltage 100 to 240 VACAllowable-input&
Omron Power Supply S8VM Series S8VM-10005CD
Omron Power Supply S8VM Series S8VM-10005CD
Standard Type , Covered Type , DIN Rail Mounting Bracket Type , Input 100 to 240 VAC , 100 W , Output 5 V 20 APower rating 100 WEfficiency 81% Min.Rated in