Cart()
 
 
Categories
Contact Us
  • A&S Power Supply Co.,Ltd
  • Address:469, Xinsheng Road, Gaoxin District, Chengdu, Sichuan, China
  • Tel:+86-28-65376776
  • Fax:+86-28-86129221
  • Email:inverter@electrical8.com
  • Contact Person:Karina
Home / Products / power supply / Omron Power Supply / S8EX / Omron Power Supply S8EX Series S8EX-N01515

Omron Power Supply S8EX Series S8EX-N01515

Omron Power Supply S8EX Series S8EX-N01515
share

Open type , Input 100 to 240 VAC , 15W , Output 15V 1A
Power rating 15 W
Efficiency 80% Min. ï¼ˆAt 100 VAC input)78% Min. ï¼ˆAt 200 VAC input)
Rated input voltage 100 to 240 VAC
Allowable-input voltage variable range 85 to 264 VAC120 to 370 VDC
Note at DC input The range for compliance with EC Directives and safety standards (UL, EN, etc.) is 100 to 240 VAC (85 to 264 VAC).
Frequency 50/60 Hz (47 to 450 Hz )
Rated input current 0.4 A TYP. ï¼ˆAt 100 VAC input)0.25 A TYP. ï¼ˆAt 200 VAC input)
Leakage current 0.5 mA Max. (At 100 VAC input)1 mA Max. (At 200 VAC input)
Inrush current 15 A TYP. ï¼ˆAt 100 VAC input (For cold start at 25 CEL))30 A TYP. ï¼ˆAt 200 VAC input (For cold start at 25 CEL))
Rated output voltage 15 VDC
Output voltage variable range -10 to +10% (With V. ADJ)(If the output voltage adjuster (V. ADJ) is turned, the voltage will increase by more than the allowable voltage range. When adjusting the output voltage, confirm the actual output voltage from the Power Supply and be sure that load is not damaged.)
Ripple 300 mV Max.
Static input variation influence 0.5% Max. (At 85 to 264 VAC input, 100% load)
Static load variation influence 1.5% Max. (At rated input, 0 to 100% load)
Ambient temperature variation influence 0.05 %/CEL Max.
Rated output current 1 A
Start up time 800 ms TYP. ï¼ˆ100 VAC input)
Hold time 20 ms TYP. ï¼ˆ100 VAC input)
Overload protection 105% to 160% of the rated output currentVoltage drop, Intermittent operation, Automatic reset
Overvoltage protection Operated at 130% Min. of the rated output voltage, Shut-offResetting: Reset the power by turning it back (OFF time: at least 3 min)
Power factor improvement function No
Parallel operation No (However, backup operation is possible; external diodes required.)
Series operation Yes (Up to 2 Power Supplies with external diode)
Applicable standard (UL) Standard No.: UL UR: UL60950-1 (Recognition)
Applicable standard (CSA) Standard No.: cUR: CSA C22.2 No.60950-1
Applicable standard (EN) Standard No.: EN50178, EN60950-1
Applicable standard (EC Directive (EMI)) Emission Enclosure: Conforms to EN55011 Group 1 Class BEmission AC mains: Conforms to EN55011 Group 1 Class B
Applicable standard(SEMI) F47-0706 (200 VAC input)
Ambient temperature Operating: -10 to 70 CELStorage: -25 to 75 CEL(with no icing or condensation)
Ambient humidity Operating: 25 to 85% RHStorage: 25 to 90% RH(With no icing or condensation)
Dielectric strength Between all inputs and all outputs: 3 kVAC for 1 min (Detection current: 20 mA)Between all inputs and PE terminals: 2 kVAC for 1 min (Detection current: 20 mA)Between all outputs and PE terminals: 1 kVAC for 1 min (Detection current: 20 mA)
Insulation resistance Between all outputs and all inputs/ PE terminals: 100 MOhm Min.
Vibration resistance 10 to 55 Hz, 19.6 m/s**2 (2 G) in each 3 directions for 1 hour
Shock resistance 196.1 m/s**2, in each 6 directions 3 times
Heat radiation Natural air-cooling
Construction Open-frame type
Weight 70 g Max.

Omron Power Supply S8JX Switch Mode Power S8JX-G10048D
Omron Power Supply S8JX Switch Mode Power S8JX-G10048D
Open-Frame Type , Input 100 to 240 VAC , 100W , Output 48V 2.1A , DIN Rail mounting typePower rating 100 WEfficiency 83% Min.Rated input voltage 100 to 240 VACAllowable-i
Omron Power Supply S8JX Switch Mode Power S8JX-P30024CD
Omron Power Supply S8JX Switch Mode Power S8JX-P30024CD
Covered type , Input 100 to 240 VAC , 300W , Output 24V 14A , DIN Rail mounting typePower rating 300 WEfficiency 79% Min.Rated input voltage 100 to 240 VACAllowable-input
Omron Power Supply S82S S82S-7728
Omron Power Supply S82S S82S-7728
Input 12 to 24 VDC , 7.5 W , Output +-15 V 0.2 A/0.2 APower rating 7.5 WEfficiency 64% Min.Rated input voltage 12 to 24 VDCAllowable-input voltage variable range 10.2 to&
Omron S8JX Switch Mode Power S8JX-G03524CD
Omron S8JX Switch Mode Power S8JX-G03524CD
Covered type , Input 100 to 240 VAC , 35 W , Output 24 V 1.5 A , DIN Rail mounting typePower rating 35 WEfficiency 73% Min.Rated input voltage 100 to 240 V
Omron Power Supply S8JX Switch Mode Power S8JX-G10048CD
Omron Power Supply S8JX Switch Mode Power S8JX-G10048CD
Covered type , Input 100 to 240 VAC , 100 W , Output 48 V 2.1 A , DIN Rail mounting typePower rating 100 WEfficiency 83% Min.Rated input voltage 100 to 240 
Omron Power Supply S8VS Series S8VS-12024BP
Omron Power Supply S8VS Series S8VS-12024BP
Standard Model , Input 100 to 240 VAC , 15 W , Output 12 V 1.2 APower rating 15 WEfficiency 79% TYP. ï¼ˆAt 100 VAC input)78% TYP. ï¼ˆAt 200 VAC input)Rate
Omron Power Supply S8VS Series S8VS-09024BP-F
Omron Power Supply S8VS Series S8VS-09024BP-F
Maintenance Forecast Monitor Type , Input 100 to 240 VAC , 90 W , Output 24 V 3.75 A , With Undervoltage Alarm (Ttransistor (Sourcing))Power rating 90 WEfficiency 83%&nbs
Omron S8JX Switch Mode Power S8JX-G03512
Omron S8JX Switch Mode Power S8JX-G03512
Open-Frame Type , Input 100 to 240 VAC , 35W , Output 12V 3A , Front-mounting typeAs of November 15, 2012Power rating 35 WEfficiency 73% Min.Rated input voltage 100 to&nb
Omron Power Supply S8VM Series S8VM-01512C
Omron Power Supply S8VM Series S8VM-01512C
Standard Type , Covered Type , Bottom Mounting Type , Input 100 to 240 VAC , 15 W , Output 12 V 1.3 APower rating 15 WEfficiency 78% Min.Rated input voltage 100
Omron Power Supply S8VS Series S8VS-48024B
Omron Power Supply S8VS Series S8VS-48024B
Total Run TimeMonitor , Input 100 to 240 VAC , 480 W , Output 24 V 20 APower rating 480 WEfficiency 85% TYP. ï¼ˆAt 100 VAC input)89% TYP. ï¼ˆAt 200 VAC&nb