Cart()
 
 
Categories
Contact Us
  • A&S Power Supply Co.,Ltd
  • Address:469, Xinsheng Road, Gaoxin District, Chengdu, Sichuan, China
  • Tel:+86-28-65376776
  • Fax:+86-28-86129221
  • Email:inverter@electrical8.com
  • Contact Person:Karina
Home / Products / power supply / Omron Power Supply / S8EX / Omron Power Supply S8EX Series S8EX-N01548LC

Omron Power Supply S8EX Series S8EX-N01548LC

Omron Power Supply S8EX Series S8EX-N01548LC
share

With chassis and cover , Input 100 to 240 VAC , 15W , Output 48V 0.32A
Power rating 15 W
Efficiency 83% Min. ï¼ˆAt 100 VAC input)82% Min. ï¼ˆAt 200 VAC input)
Rated input voltage 100 to 240 VAC
Allowable-input voltage variable range 85 to 264 VAC120 to 370 VDC
Note at DC input The range for compliance with EC Directives and safety standards (UL, EN, etc.) is 100 to 240 VAC (85 to 264 VAC).
Frequency 50/60 Hz (47 to 450 Hz )
Rated input current 0.4 A TYP. ï¼ˆAt 100 VAC input)0.25 A TYP. ï¼ˆAt 200 VAC input)
Leakage current 0.5 mA Max. (At 100 VAC input)1 mA Max. (At 200 VAC input)
Inrush current 15 A TYP. ï¼ˆAt 100 VAC input (For cold start at 25 CEL))30 A TYP. ï¼ˆAt 200 VAC input (For cold start at 25 CEL))
Rated output voltage 48 VDC
Output voltage variable range -10 to +10% (With V. ADJ)(If the output voltage adjuster (V. ADJ) is turned, the voltage will increase by more than the allowable voltage range. When adjusting the output voltage, confirm the actual output voltage from the Power Supply and be sure that load is not damaged.)
Ripple 960 mV Max.
Static input variation influence 0.5% Max. (At 85 to 264 VAC input, 100% load)
Static load variation influence 1.5% Max. (At rated input, 0 to 100% load)
Ambient temperature variation influence 0.05 %/CEL Max.
Rated output current 0.32 A
Start up time 800 ms TYP. ï¼ˆ100 VAC input)
Hold time 20 ms TYP. ï¼ˆ100 VAC input)
Overload protection 105% to 160% of the rated output currentVoltage drop, Intermittent operation, Automatic reset
Overvoltage protection Operated at 130% Min. of the rated output voltage, Shut-offResetting: Reset the power by turning it back (OFF time: at least 3 min)
Power factor improvement function No
Parallel operation No (However, backup operation is possible; external diodes required.)
Series operation Yes (Up to 2 Power Supplies with external diode)
Applicable standard (UL) Standard No.: UL UR: UL60950-1 (Recognition)
Applicable standard (CSA) Standard No.: cUR: CSA C22.2 No.60950-1
Applicable standard (EN) Standard No.: EN50178, EN60950-1
Applicable standard (EC Directive (EMI)) Emission Enclosure: Conforms to EN55011 Group 1 Class BEmission AC mains: Conforms to EN55011 Group 1 Class B
Applicable standard(SEMI) F47-0706 (200 VAC input)
Ambient temperature Operating: -10 to 70 CELStorage: -25 to 75 CEL(with no icing or condensation)
Ambient humidity Operating: 25 to 85% RHStorage: 25 to 90% RH(With no icing or condensation)
Dielectric strength Between all inputs and all outputs: 3 kVAC for 1 min (Detection current: 20 mA)Between all inputs and PE terminals: 2 kVAC for 1 min (Detection current: 20 mA)Between all outputs and PE terminals: 1 kVAC for 1 min (Detection current: 20 mA)
Insulation resistance Between all outputs and all inputs/ PE terminals: 100 MOhm Min.
Vibration resistance 10 to 55 Hz, 19.6 m/s**2 (2 G) in each 3 directions for 1 hour
Shock resistance 196.1 m/s**2, in each 6 directions 3 times
Heat radiation Natural air-cooling
Construction With chassis and cover

Omron Power Supply S8VS Series S8VS-24024BP
Omron Power Supply S8VS Series S8VS-24024BP
Total Run Time Monitor , Input 100 to 240 VAC , 240 W , Output 24 V 10 A , With Undervoltage Alarm (Ttransistor (Sourcing))Power rating 240 WEfficiency 85% TYP. 
Omron Power Supply S8VM Series S8VM-03024D
Omron Power Supply S8VM Series S8VM-03024D
Standard Type , Open-Frame Type , DIN Rail Mounting Bracket Type , Input 100 to 240 VAC , 30 W , Output 24 V 1.3 APower rating 30 WEfficiency 81% Min.Rated 
Omron S8JX Switch Mode Power S8JX-P10005C
Omron S8JX Switch Mode Power S8JX-P10005C
Covered type , Input 100 to 240 VAC , 100W , Output 5V 20A , Front-mounting typePower rating 100 WEfficiency 78% Min.Rated input voltage 100 to 240 VACAllowable-input voltage&
Omron Power Supply S8VM Series S8VM-01515D
Omron Power Supply S8VM Series S8VM-01515D
Standard Type , Open-Frame Type , DIN Rail Mounting Bracket Type , Input 100 to 240 VAC , 15 W , Output 15 V 1 APower rating 15 WEfficiency 78% Min.Rated i
Omron S8JX Switch Mode Power S8JX-G03548D
Omron S8JX Switch Mode Power S8JX-G03548D
Open-Frame Type , Input 100 to 240 VAC , 35W , Output 48V 0.75A , DIN Rail mounting typePower rating 35 WEfficiency 73% Min.Rated input voltage 100 to 240 VACAllowable-in
Omron Power Supply S8EX Series S8EX-N01548
Omron Power Supply S8EX Series S8EX-N01548
Open type , Input 100 to 240 VAC , 15W , Output 48V 0.32APower rating 15 WEfficiency 83% Min. ï¼ˆAt 100 VAC input)82% Min. ï¼ˆAt 200 VAC input)Rated inp
Omron S8JX Switch Mode Power S8JX-G03515D
Omron S8JX Switch Mode Power S8JX-G03515D
Open-Frame Type , Input 100 to 240 VAC , 35W , Output 15V 2.4A , DIN Rail mounting typeAs of November 15, 2012Power rating 35 WEfficiency 73% Min.Rated input voltage
Omron S8JX Switch Mode Power S8JX-G05005C
Omron S8JX Switch Mode Power S8JX-G05005C
Covered type , Input 100 to 240 VAC , 50 W , Output 5 V 10 A , Front-mounting typePower rating 50 WEfficiency 76% Min.Rated input voltage 100 to 240 VACAllowable-inp
Omron Power Supply S8EX Series S8EX-BP15048
Omron Power Supply S8EX Series S8EX-BP15048
Open type , Input 100 to 240 VAC , 150W , Output 48V 3.2APower rating 150 WEfficiency 85% Min. ï¼ˆAt 100 VAC input)88% Min. ï¼ˆAt 200 VAC input)Rated in
Omron Power Supply S8VS Series S8VS-24024
Omron Power Supply S8VS Series S8VS-24024
Standard Model , Input 100 to 240 VAC , 240 W , Output 24 V 10 APower rating 240 WEfficiency 85% TYP. ï¼ˆAt 100 VAC input)88% TYP. ï¼ˆAt 200 VAC input)Rat