- power supply
- TDK Lambda Power Supply
- Yamaha Power Supply
- Omron Power Supply
- Plus Power Supply
- Bestec Power Supply
- Sorensen Power Supply
- Antec Power Supply
- Meanwell Power Supply
- Weidmuller Power Supply
- Hipro Power Supply
- Sparkle Power Supply
- Lenovo Power Supply
- Zippy Power Supply
- Enermax Power Supply
- Agilent Power Supply
- Phihong Power Supply
- Liteon power supply
- Acble Power Supply
- Instek Power Supply
- Zalman Power Supply
- FSP Power Supply
- Aopen Power Supply
- Spellman Supply
- Delta Supply
- Cosel Supply
- Aj`s Power Source Supply
- Coolmax Supply
- MEAN WELL Power Supply
- SENDON Power Supply
- MGE Power Supply
- UPS Power Supply
- APC UPS Power Supply
- Riello UPS Power Supply
- EATON UPS Power Supply
- SANTAK UPS Power Supply
- Siemens UPS Power Supply
- Powerware UPS Power Supply
- OMRON UPS Power Supply
- Mitsubishi UPS Power Suppply
- DELTA Uninterruptible Power Supply
- EAST UPS Power Supply
- EMERSON UPS Power Supply
- Fuji UPS Power Supply
- EFFEKTA Uninterruptible Power Supply
- Gutor UPS Power Supply
- KELONG UPS Power Supply
- LADIS Uninterruptible Power Supply
- CBC UPS Power Supply
- Phoenix UPS Power Supply
- SVC Uninterruptible Power Supply
- Avaya UPS Power Supply
- NETCCA Uninterruptible Power Supply
- battery
- inverter
- Xantrex inverter
- Samlex inverter
- Schumacher inverter
- KACO inverter
- Wagan inverter
- AIMS inverter
- Victron inverter
- Targus inverter
- Whistler inverter
- Enphase inverter
- Satcon inverter
- Sima inverter
- Kensington inverter
- Exeltech inverter
- Stanley inverter
- ABB inverter
- SMA inverter
- Hyundai inverter
- Mastervolt inverter
- YAMAHA inverter
- Belkin inverter
- Microtek inverter
- Growatt inverter
- TDK inverter
- TOSHIBA inverter
- Su kam inverter
- Omnik inverter
- Ingeteam inverter
- Samil Power inverter
- Sungrow inverter
- Cobra inverter
- Power Bright inverter
- Bestek inverter
- A&S Power Supply Co.,Ltd
- Address:469, Xinsheng Road, Gaoxin District, Chengdu, Sichuan, China
- Tel:+86-28-65376776
- Fax:+86-28-86129221
- Email:inverter@electrical8.com
- Contact Person:Karina
Omron Power Supply S8EX Series S8EX-P10005LC
With chassis and cover , Input 100 to 240 VAC , 100W , Output 5V 20A
Power rating 100 W
Efficiency 81% Min. (At 100 VAC input)84% Min. (At 200 VAC input)
Rated input voltage 100 to 240 VAC
Allowable-input voltage variable range 85 to 264 VAC120 to 370 VDC
Note at DC input The range for compliance with EC Directives and safety standards (UL, EN, etc.) is 100 to 240 VAC (85 to 264 VAC).
Frequency 50/60 Hz (47 to 63 Hz )
Rated input current 1.3 A TYP. (At 100 VAC input)0.65 A TYP. (At 200 VAC input)
Power factor 0.9 Min. (At rated input, 100% load)
Harmonic Current EN61000-3-2
Leakage current 0.5 mA Max. (At 100 VAC input)1 mA Max. (At 200 VAC input)
Inrush current 14.1 A TYP. (At 100 VAC input (For cold start at 25 CEL))28.3 A TYP. (At 200 VAC input (For cold start at 25 CEL))
Rated output voltage 5 VDC
Output voltage variable range -10 to +10% (With V. ADJ)(If the output voltage adjuster (V. ADJ) is turned, the voltage will increase by more than the allowable voltage range. When adjusting the output voltage, confirm the actual output voltage from the Power Supply and be sure that load is not damaged.)
Ripple 150 mV Max.
Static input variation influence 0.5% Max. (At 85 to 264 VAC input, 100% load)
Static load variation influence 2% Max. (At rated input, 0 to 100% load)
Ambient temperature variation influence 0.05 %/CEL Max.
Rated output current 20 A
Start up time 480 ms TYP. (100 VAC input)
Hold time 24 ms TYP. (100 VAC input)
Overload protection 105% to 160% of the rated output currentVoltage drop, Intermittent operation, Automatic reset
Overvoltage protection Operated at 130% Min. of the rated output voltage, Shut-offResetting: Reset the power by turning it back (OFF time: at least 3 min)
Power factor improvement function Yes
Parallel operation No (However, backup operation is possible; external diodes required.)
Series operation Yes (Up to 2 Power Supplies)
Applicable standard (UL) Standard No.: UL UR: UL60950-1 (Recognition)
Applicable standard (CSA) Standard No.: cUR: CSA C22.2 No.60950-1
Applicable standard (EN) Standard No.: EN50178, EN60950-1
Applicable standard (EC Directive (EMI)) Emission Enclosure: Conforms to EN55011 Group 1 Class BEmission AC mains: Conforms to EN55011 Group 1 Class B
Applicable standard(SEMI) F47-0706 (200 VAC input)
Ambient temperature Operating: -10 to 70 CELStorage: -25 to 75 CEL(with no icing or condensation)
Ambient humidity Operating: 25 to 85% RHStorage: 25 to 90% RH(With no icing or condensation)
Dielectric strength Between all inputs and all outputs: 3 kVAC for 1 min (Detection current: 20 mA)Between all inputs and PE terminals: 2 kVAC for 1 min (Detection current: 20 mA)Between all outputs and PE terminals: 1 kVAC for 1 min (Detection current: 20 mA)
Insulation resistance Between all outputs and all inputs/ PE terminals: 100 MOhm Min.
Vibration resistance 10 to 55 Hz, 19.6 m/s**2 (2 G) in each 3 directions for 1 hour
Shock resistance 196.1 m/s**2, in each 6 directions 3 times
Heat radiation Natural air-cooling
Construction With chassis and cover
Total Run Time Monitor , Input 100 to 240 VAC , 90 W , Output 24 V 3.75 APower rating 90 WEfficiency 83% TYP. (At 100 VAC input)85% TYP. (At 200
Covered type , Input 100 to 240 VAC , 15 W , Output 12 V 1.3 A , Front-mounting typeAs of November 15, 2012Power rating 15 WEfficiency 68% Min.Rated input volta
Covered type , Input 100 to 240 VAC , 35 W , Output 5 V 7 A , Front-mounting typeAs of November 15, 2012Power rating 35 WEfficiency 73% Min.Rated input voltage
Total Run Time Monitor , Input 100 to 240 VAC , 240 W , Output 24 V 10 A , With Undervoltage Alarm (Ttransistor (Sourcing))Power rating 240 WEfficiency 85% TYP. 
Input 12 to 24 VDC , 3 W , Output 5 V 0.6 APower rating 3 WEfficiency 60% Min.Rated input voltage 12 to 24 VDCAllowable-input voltage variable range 10.2 to 27.6 VDC
Open type , Input 100 to 240 VAC , 15W , Output 15V 1APower rating 15 WEfficiency 80% Min. (At 100 VAC input)78% Min. (At 200 VAC input)Rated input&
Open-Frame Type , Input 100 to 240 VAC , 100W , Output 48V 2.1A , Front-mounting typePower rating 100 WEfficiency 83% Min.Rated input voltage 100 to 240 VACAllowable-input vol
Total Run Time Monitor , Input 100 to 240 VAC , 90 W , Output 24 V 3.75 APower rating 90 WEfficiency 83% TYP. (At 100 VAC input)85% TYP. (At 200
Covered type , Input 100 to 240 VAC , 35 W , Output 24 V 1.5 A , Front-mounting typePower rating 35 WEfficiency 73% Min.Rated input voltage 100 to 240 VACAllowable-i
Open-Frame Type , Input 100 to 240 VAC , 50W , Output 48V 1.1A , DIN Rail mounting typePower rating 50 WEfficiency 80% Min.Rated input voltage 100 to 240 VACAllowable-inp