Omron Power Supply S8VS Series S8VS-06024B-F

Omron Power Supply S8VS Series S8VS-06024B-F
share

Standard Model , Input 100 to 240 VAC , 120 W , Output 24 V 5 A
Power rating 120 W
Efficiency 84% TYP. ï¼ˆAt 100 VAC input)87% TYP. ï¼ˆAt 200 VAC input)
Rated input voltage 100 to 240 VAC
Allowable-input voltage variable range 85 to 264 VAC80 to 370 VDC
Note at DC input The range for compliance with EC Directives and safety standards (UL, EN, etc.) is 100 to 240 VAC (85 to 264 VAC).
Frequency 50/60 Hz (47 to 63 Hz Single-phase)
Rated input current 1.5 A TYP. ï¼ˆAt 100 VAC input)0.71 A TYP. ï¼ˆAt 200 VAC input)
Power factor 0.9 Min.
Harmonic Current EN61000-3-2
Leakage current 0.5 mA Max. (At 100 VAC input)1.0 mA Max. (At 200 VAC input)
Inrush current 14 A TYP. ï¼ˆAt 100 VAC input (For cold start at 25 CEL))28 A TYP. ï¼ˆAt 200 VAC input (For cold start at 25 CEL))
Rated output voltage 24 VDC
Output voltage variable range -10 to +15% (With V. ADJ)(The output voltage may increase beyond the allowable voltage range (up to +15% of the rated voltage) depending on the operation of the output voltage adjuster (V.ADJ). When adjusting the output voltage, check the output voltage of the Power Supply and be sure that the load is not damaged.)
Ripple 2%(p-p) Max. (Under the rated I/O conditions.)60 mV Max. (Under the rated I/O conditions.)
Static input variation influence 0.5% Max. (At 85 to 264 VAC input, 100% load)
Static load variation influence 1.5% Max. (At rated input, 0 to 100% load)
Ambient temperature variation influence 0.05 %/CEL Max.
Rated output current 5 A
Start up time 550 ms TYP. ï¼ˆ100 VAC input)430 ms TYP. ï¼ˆ200 VAC input)
Hold time 52 ms TYP. ï¼ˆ100 VAC input)54 ms TYP. ï¼ˆ200 VAC input)
Overload protection 105% to 160% of the rated output currentInverted L voltage drop, Automatic reset
Overvoltage protection Operated at 115 to 150 % of the rated output voltage, Shut-offResetting: Reset the power by turning it back (OFF time: at least 3 min)
Overheat protection No
Maintenance forecast monitor output No
Total run time monitor output No
Undervoltage alarm output No
Power failure alarm output No
Parallel operation No (However, backup operation is possible; external diodes required.)
Series operation Yes (Up to 2 Power Supplies with external diode)
Remote sensing function No
Applicable standard (UL) Standard No.: UL Listed: UL508 (Listing), UL UR: UL60950-1 (Recognition)
Applicable standard (CSA) Standard No.: cUL: CSA C22.2 No.107.1, cUR: CSA C22.2 No.60950-1
Applicable standard (EN) Standard No.: EN50178, EN60950-1
Applicable standard (EC Directive (EMI)) EMI: EN61204-3 Class BEmission Enclosure: Conforms to EN55011 Group 1 Class BEmission AC mains: Conforms to EN55011 Group 1 Class B and based on FCC Class AEMS: EN61204-3 High severity levels
Applicable standard(VDE) Standard No.: VDE0160, VDE0805 Teil 1 File number:
Applicable standard(SEMI) F47-0200 (200 VAC input)
Ambient temperature Operating: -10 to 60 CELStorage: -25 to 65 CEL(with no icing or condensation)
Ambient humidity Operating: 25 to 85%Storage: 25 to 90%(With no icing or condensation)
Dielectric strength Between all inputs and all outputs/alarm outputs: 3 kVAC for 1 min (Detection current: 20 mA)Between all inputs and PE terminals: 2 kVAC for 1 min (Detection current: 20 mA)Between all outputs/alarm outputs and all PE terminals: 1 kVAC for 1 min (Detection current: 30 mA)Between all outputs and all alarm outputs: 500 VAC for 1 min (Detection current: 20 mA)
Insulation resistance Between all outputs/alarm outputs and all inputs/PE terminals: 100 MOhm Min. (at 500 VDC)
Vibration resistance 10 to 55 Hz, 0.375 mm single amplitude in each 3 directions for 2 hours
Shock resistance 150 m/s**2, in each 6 directions 3 times
Output indicator Yes (color: green)
Heat radiation Natural air-cooling
Construction Covered type
Terminal type Screw terminal
Mounting type DIN Rail mounting type
Weight 550 g Max.

Omron Power Supply S8EX Series S8EX-N03024LC
Omron Power Supply S8EX Series S8EX-N03024LC
With chassis and cover , Input 100 to 240 VAC , 30W , Output 24V 1.3APower rating 30 WEfficiency 85% Min. ï¼ˆAt 100 VAC input)86% Min. ï¼ˆAt 200 VAC inpu
Omron Power Supply S82S S82S-7724
Omron Power Supply S82S S82S-7724
Input 12 to 24 VDC , 7.5 W , Output 24 V 0.3 APower rating 7.5 WEfficiency 70% Min.Rated input voltage 12 to 24 VDCAllowable-input voltage variable range 10.2 to 27.6&nbs
Omron S8JX Switch Mode Power S8JX-G05012CD
Omron S8JX Switch Mode Power S8JX-G05012CD
Covered type , Input 100 to 240 VAC , 50 W , Output 12 V 4.2 A , DIN Rail mounting typePower rating 50 WEfficiency 81% Min.Rated input voltage 100 to 240 V
Omron Power Supply S8EX Series S8EX-BP10024L
Omron Power Supply S8EX Series S8EX-BP10024L
With chassis , Input 100 to 240 VAC , 100W , Output 24V 4.3APower rating 100 WEfficiency 84% Min. ï¼ˆAt 100 VAC input)86% Min. ï¼ˆAt 200 VAC input)Rated 
Omron Power Supply S8JX Switch Mode Power S8JX-P15024C
Omron Power Supply S8JX Switch Mode Power S8JX-P15024C
Covered type , Input 100 to 240 VAC , 150W , Output 24V 6.5A , Front-mounting typePower rating 150 WEfficiency 81% Min.Rated input voltage 100 to 240 VACAllowable-input voltag
Omron Power Supply S8EX Series S8EX-BP15024L
Omron Power Supply S8EX Series S8EX-BP15024L
With chassis , Input 100 to 240 VAC , 150W , Output 24V 6.3APower rating 150 WEfficiency 84% Min. ï¼ˆAt 100 VAC input)87% Min. ï¼ˆAt 200 VAC input)Rated 
Omron S8JX Switch Mode Power S8JX-G03505C
Omron S8JX Switch Mode Power S8JX-G03505C
Covered type , Input 100 to 240 VAC , 35 W , Output 5 V 7 A , Front-mounting typeAs of November 15, 2012Power rating 35 WEfficiency 73% Min.Rated input voltage
Omron Power Supply S8EX Series S8EX-BP15012L
Omron Power Supply S8EX Series S8EX-BP15012L
With chassis , Input 100 to 240 VAC , 150W , Output 12V 12.5APower rating 150 WEfficiency 83% Min. ï¼ˆAt 100 VAC input)86% Min. ï¼ˆAt 200 VAC input)Rated&nbs
Omron S8JX Switch Mode Power S8JX-G05012D
Omron S8JX Switch Mode Power S8JX-G05012D
Open-Frame Type , Input 100 to 240 VAC , 50W , Output 12V 4.2A , DIN Rail mounting typePower rating 50 WEfficiency 81% Min.Rated input voltage 100 to 240 VACAllowable-inp
Omron Power Supply S8VS Series S8VS-09024BE-F
Omron Power Supply S8VS Series S8VS-09024BE-F
Total Run Time Monitor , Input 100 to 240 VAC , 90 W , Output 24 V 3.75 APower rating 90 WEfficiency 83% TYP. ï¼ˆAt 100 VAC input)85% TYP. ï¼ˆAt 200