- power supply
- TDK Lambda Power Supply
- Yamaha Power Supply
- Omron Power Supply
- Plus Power Supply
- Bestec Power Supply
- Sorensen Power Supply
- Antec Power Supply
- Meanwell Power Supply
- Weidmuller Power Supply
- Hipro Power Supply
- Sparkle Power Supply
- Lenovo Power Supply
- Zippy Power Supply
- Enermax Power Supply
- Agilent Power Supply
- Phihong Power Supply
- Liteon power supply
- Acble Power Supply
- Instek Power Supply
- Zalman Power Supply
- FSP Power Supply
- Aopen Power Supply
- Spellman Supply
- Delta Supply
- Cosel Supply
- Aj`s Power Source Supply
- Coolmax Supply
- MEAN WELL Power Supply
- SENDON Power Supply
- MGE Power Supply
- UPS Power Supply
- APC UPS Power Supply
- Riello UPS Power Supply
- EATON UPS Power Supply
- SANTAK UPS Power Supply
- Siemens UPS Power Supply
- Powerware UPS Power Supply
- OMRON UPS Power Supply
- Mitsubishi UPS Power Suppply
- DELTA Uninterruptible Power Supply
- EAST UPS Power Supply
- EMERSON UPS Power Supply
- Fuji UPS Power Supply
- EFFEKTA Uninterruptible Power Supply
- Gutor UPS Power Supply
- KELONG UPS Power Supply
- LADIS Uninterruptible Power Supply
- CBC UPS Power Supply
- Phoenix UPS Power Supply
- SVC Uninterruptible Power Supply
- Avaya UPS Power Supply
- NETCCA Uninterruptible Power Supply
- battery
- inverter
- Xantrex inverter
- Samlex inverter
- Schumacher inverter
- KACO inverter
- Wagan inverter
- AIMS inverter
- Victron inverter
- Targus inverter
- Whistler inverter
- Enphase inverter
- Satcon inverter
- Sima inverter
- Kensington inverter
- Exeltech inverter
- Stanley inverter
- ABB inverter
- SMA inverter
- Hyundai inverter
- Mastervolt inverter
- YAMAHA inverter
- Belkin inverter
- Microtek inverter
- Growatt inverter
- TDK inverter
- TOSHIBA inverter
- Su kam inverter
- Omnik inverter
- Ingeteam inverter
- Samil Power inverter
- Sungrow inverter
- Cobra inverter
- Power Bright inverter
- Bestek inverter
- A&S Power Supply Co.,Ltd
- Address:469, Xinsheng Road, Gaoxin District, Chengdu, Sichuan, China
- Tel:+86-28-65376776
- Fax:+86-28-86129221
- Email:inverter@electrical8.com
- Contact Person:Karina
Omron Power Supply S8VS Series S8VS-12024BP
Standard Model , Input 100 to 240 VAC , 15 W , Output 12 V 1.2 A
Power rating 15 W
Efficiency 79% TYP. (At 100 VAC input)78% TYP. (At 200 VAC input)
Rated input voltage 100 to 240 VAC
Allowable-input voltage variable range 85 to 264 VAC80 to 370 VDC
Note at DC input The range for compliance with EC Directives and safety standards (UL, EN, etc.) is 100 to 240 VAC (85 to 264 VAC).
Frequency 50/60 Hz (47 to 450 Hz Single-phase)
Rated input current 0.34 A TYP. (At 100 VAC input)0.22 A TYP. (At 200 VAC input)
Harmonic Current EN61000-3-2
Leakage current 0.5 mA Max. (At 100 VAC input)1.0 mA Max. (At 200 VAC input)
Inrush current 14 A TYP. (At 100 VAC input (For cold start at 25 CEL))28 A TYP. (At 200 VAC input (For cold start at 25 CEL))
Rated output voltage 12 VDC
Output voltage variable range -10 to +15% (With V. ADJ)(The output voltage may increase beyond the allowable voltage range (up to +15% of the rated voltage) depending on the operation of the output voltage adjuster (V.ADJ). When adjusting the output voltage, check the output voltage of the Power Supply and be sure that the load is not damaged.)
Ripple 2%(p-p) Max. (Under the rated I/O conditions.)70 mV Max. (Under the rated I/O conditions.)
Static input variation influence 0.5% Max. (At 85 to 264 VAC input, 100% load)
Static load variation influence 1.5% Max. (Output voltage: 12 V, at rated input, 0 to 100% load)
Ambient temperature variation influence 0.05 %/CEL Max.
Rated output current 1.2 A
Start up time 530 ms TYP. (100 VAC input)360 ms TYP. (200 VAC input)
Hold time 27 ms TYP. (100 VAC input)134 ms TYP. (200 VAC input)
Overload protection 105% to 160% of the rated output currentInverted L voltage drop, Intermittent operation, Automatic reset
Overvoltage protection Operated at 130% Min. of the rated output voltage, Shut-offResetting: Reset the power by turning it back (OFF time: at least 3 min)
Overheat protection No
Maintenance forecast monitor output No
Total run time monitor output No
Undervoltage alarm output No
Power failure alarm output No
Parallel operation No (However, backup operation is possible; external diodes required.)
Series operation No
Remote sensing function No
Applicable standard (UL) Standard No.: UL508 (Listing, Class 2: Per UL1310), UL UR: UL60950-1 (Recognition)
Applicable standard (CSA) Standard No.: cUL: CSA C22.2 No.107.1 (Class 2: Per No.223), cUR: CSA C22.2 No.60950-1
Applicable standard (EN) Standard No.: EN50178, EN60950-1
Applicable standard (EC Directive (EMI)) Emission Enclosure: Conforms to EN61204-3 Class BEmission AC mains: Conforms to EN61204-3 Class B and based on FCC Class AEMS: EN61204-3 Class B
Applicable standard(VDE) Standard No.: VDE0160, VDE0805 Teil 1 File number:
Applicable standard(SEMI) F47-0200 (200 VAC input)
Ambient temperature Operating: -10 to 60 CELStorage: -25 to 65 CEL(with no icing or condensation)
Ambient humidity Operating: 25 to 85%Storage: 25 to 90%(With no icing or condensation)
Dielectric strength Between all inputs and all outputs: 3 kVAC for 1 min (Detection current: 20 mA)Between all inputs and PE terminals: 2 kVAC for 1 min (Detection current: 20 mA)Between all outputs and PE terminals: 1 kVAC for 1 min (Detection current: 20 mA)
Insulation resistance Between all outputs and all inputs/ PE terminals: 100 MOhm Min. (at 500 VDC)
Vibration resistance 10 to 55 Hz, 0.375 mm single amplitude in each 3 directions for 2 hours
Shock resistance 150 m/s**2, in each 6 directions 3 times
Output indicator Yes (color: green)
Heat radiation Natural air-cooling
Construction Covered type
Terminal type Screw terminal
Mounting type DIN Rail mounting type
Weight 160 g Max.
Total Run Time Monitor , Input 100 to 240 VAC , 240 W , Output 24 V 10 APower rating 240 WEfficiency 85% TYP. (At 100 VAC input)88% TYP. (At 200
Covered type , Input 100 to 240 VAC , 300W , Output 48V 7A , Front-mounting typePower rating 300 WEfficiency 78% Min.Rated input voltage 100 to 240 VACAllowable-input voltage&
Covered type , Input 100 to 240 VAC , 15 W , Output 24 V 0.65 A , Front-mounting typeAs of November 15, 2012Power rating 15 WEfficiency 68% Min.Rated input volt
Standard Type , Covered Type , Bottom Mounting Type , Input 100 to 240 VAC , 100 W , Output 12 V 8.5 APower rating 100 WEfficiency 81% Min.Rated input voltage 1
Standard Model , Input 100 to 240 VAC , 180 W , Output 24 V 7.5 A , Screwless Terminal BlockPower rating 180 WEfficiency 85% TYP. (At 100 VAC input)88% TYP
With chassis , Input 100 to 240 VAC , 150W , Output 48V 3.2APower rating 150 WEfficiency 85% Min. (At 100 VAC input)88% Min. (At 200 VAC input)Rated 
Open-Frame Type , Input 100 to 240 VAC , 15W , Output 5V 3A , Front-mounting typePower rating 15 WEfficiency 68% Min.Rated input voltage 100 to 240 VACAllowable-input voltage&
Standard Type , Open-Frame Type , Bottom Mounting Type , Input 100 to 240 VAC , 100 W , Output 12 V 8.5 APower rating 100 WEfficiency 81% Min.Rated input voltag
Open-Frame Type , Input 100 to 240 VAC , 15W , Output 24V 0.65A , Front-mounting typeAs of November 15, 2012Power rating 15 WEfficiency 68% Min.Rated input voltage 100 to
Maintenance Forecast Monitor Type , Input 100 to 240 VAC , 240 W , Output 24 V 10 APower rating 240 WEfficiency 85% TYP. (At 100 VAC input)88% TYP. (At&nbs