Cart()
 
 
Categories
Contact Us
  • A&S Power Supply Co.,Ltd
  • Address:469, Xinsheng Road, Gaoxin District, Chengdu, Sichuan, China
  • Tel:+86-28-65376776
  • Fax:+86-28-86129221
  • Email:inverter@electrical8.com
  • Contact Person:Karina
Home / Products / power supply / Omron Power Supply / S8TX / Omron Power Supply S8TX Series S8TS-03012F-E1

Omron Power Supply S8TX Series S8TS-03012F-E1

Omron Power Supply S8TX Series S8TS-03012F-E1
share

Basic Block , Connector Terminal Type , Input 100 to 240 VAC , Output 12 V 2.5 A
Power rating 30 W
Efficiency 73% TYP. ï¼ˆAt rated input, 100% load)
Rated input voltage 100 to 240 VAC
Allowable-input voltage variable range 85 to 264 VAC80 to 370 VDC
Note at DC input The range for compliance with EC Directives and safety standards (UL, EN, etc.) is 100 to 240 VAC (85 to 264 VAC).
Frequency 50/60 Hz (47 to 63 Hz Single-phase)
Rated input current 0.7 A Max. ï¼ˆAt 100 VAC input)0.4 A Max. ï¼ˆAt 200 VAC input)
Power factor 0.8 Min. (At rated input, 100% load)
Harmonic Current EN61000-3-2
Leakage current 0.35 mA Max. (At 100 VAC input)0.7 mA Max. (At 240 VAC input)
Inrush current 17.5 A Max. ï¼ˆAt 100 VAC input (For cold start at 25 CEL))35 A Max. ï¼ˆAt 200 VAC input (For cold start at 25 CEL))
Rated output voltage 12 VDC
Output voltage variable range -10 to +10% (With V. ADJ)(The output voltage may increase beyond the allowable voltage range (up to +10% of the rated voltage) depending on the operation of the output voltage adjuster (V.ADJ). When adjusting the output voltage, check the output voltage of the Power Supply and be sure that the load is not damaged.)
Ripple 2%(p-p) Max. (Under the rated I/O conditions.)
Static input variation influence 0.5% Max. (At 85 to 264 VAC input, 100% load)
Static load variation influence 5% Max. (Single operation, 0 to 100% load)2% Max. (Single operation, 10 to 100% load)5.5% Max. (Parallel operation, 0 to 100% load)3% Max. (Parallel operation, 10 to 100% load)
Ambient temperature variation influence 0.05 %/CEL Max.
Rated output current 2.5 A
Start up time 1000 ms Max. ï¼ˆ100/200 VAC, rated input)
Hold time 20 ms Min. (100/200 VAC, rated input)
Overload protection 105% to 140% of the rated output current (Single operation), 100% to 140% of the rated output current (Parallel operation)Inverted L voltage drop, Automatic reset
Overvoltage protection Operated at 115 to 145 % of the rated output voltage, Shut-offResetting: Reset the power by turning it back (OFF time: at least 1 min)
Maintenance forecast monitor output No
Total run time monitor output No
Undervoltage alarm output Yes (open collector output), 30 VDC Max., 50 mA Max.
Parallel operation Yes (Up to 4 Blocks)
N+1 redundant system Yes (Up to 5 Blocks)
Series operation Yes
Applicable standard (UL) Standard No.: UL Listed: UL508 (Listing), UL UR: UL60950-1 (Recognition)
Applicable standard (CSA) Standard No.: cUL Listed: CSA C22.2 No.107.1, cUR: CSA C22.2 No.60950-1
Applicable standard (EN) Standard No.: EN50178, EN60950-1
Applicable standard (EC Directive (EMI)) EMI: EN61204-3Emission Enclosure: Conforms to EN61204-3 Class BEmission AC mains: Conforms to EN61204-3 Class B and based on FCC Class AEMS: EN61204-3
Applicable standard(VDE) Standard No.: VDE0160, VDE0805 Teil 1 File number:
Ambient temperature Operating: -10 to 60 CELStorage: -25 to 65 CEL(with no icing or condensation)
Ambient humidity Operating: 25 to 85% RHStorage: 25 to 90% RH(With no condensation)
Dielectric strength Between all inputs and all outputs: 3 kVAC for 1 min (Detection current: 20 mA)Between all inputs and PE terminals: 2 kVAC for 1 min (Detection current: 20 mA)Between all outputs and PE terminals: 1 kVAC for 1 min (Detection current: 20 mA)
Insulation resistance Between all outputs and all inputs/ PE terminals: 100 MOhm Min. (at 500 VDC)
Vibration resistance 10 to 55 Hz, 0.375 mm single amplitude in each 3 directions for 2 hours
Shock resistance 150 m/s**2, in each 6 directions 3 times
Output indicator Yes (color: green)
Heat radiation Natural air-cooling
Construction Covered type
Structure Connector terminals
Mounting type DIN Rail mounting type
Attachment Housing for connector terminals / Bus Line Connector
Weight 450 g Max.

Omron S8JX Switch Mode Power S8JX-G03548D
Omron S8JX Switch Mode Power S8JX-G03548D
Open-Frame Type , Input 100 to 240 VAC , 35W , Output 48V 0.75A , DIN Rail mounting typePower rating 35 WEfficiency 73% Min.Rated input voltage 100 to 240 VACAllowable-in
Omron S8JX Switch Mode Power S8JX-G60024C
Omron S8JX Switch Mode Power S8JX-G60024C
Covered type , Input 100/200 VAC , 100 W , Output 24 V 27 A , Front-mounting type Power rating 600 W Efficiency 80% Min. Rated input voltage 100 to 120 VAC200 to 
Omron Power Supply S8VM Series S8VM-10005
Omron Power Supply S8VM Series S8VM-10005
Standard Type , Open-Frame Type , Bottom Mounting Type , Input 100 to 240 VAC , 100 W , Output 5 V 20 APower rating 100 WEfficiency 81% Min.Rated input voltage
Omron Power Supply S8VM Series S8VM-05005D
Omron Power Supply S8VM Series S8VM-05005D
Standard Type , Open-Frame Type , DIN Rail Mounting Bracket Type , Input 100 to 240 VAC , 50 W , Output 5 V 10 APower rating 50 WEfficiency 80% Min.Rated i
Omron S8JX Switch Mode Power S8JX-G03512C
Omron S8JX Switch Mode Power S8JX-G03512C
Covered type , Input 100 to 240 VAC , 35 W , Output 12 V 3 A , Front-mounting typeAs of November 15, 2012Power rating 35 WEfficiency 73% Min.Rated input voltage
Omron Power Supply S8JX Switch Mode Power S8JX-P15048C
Omron Power Supply S8JX Switch Mode Power S8JX-P15048C
Covered type , Input 100 to 240 VAC , 150W , Output 48V 3.3A , Front-mounting typePower rating 150 WEfficiency 82% Min.Rated input voltage 100 to 240 VACAllowable-input voltag
Omron Power Supply S8VM Series S8VM-01505
Omron Power Supply S8VM Series S8VM-01505
Standard Type , Open-Frame Type , Bottom Mounting Type , Input 100 to 240 VAC , 15 W , Output 5 V 3 APower rating 15 WEfficiency 75% Min.Rated input voltage 100
Omron Power Supply S8EX Series S8EX-N03012L
Omron Power Supply S8EX Series S8EX-N03012L
With chassis , Input 100 to 240 VAC , 30W , Output 12V 2.5APower rating 30 WEfficiency 82% Min. ï¼ˆAt 100 VAC input)83% Min. ï¼ˆAt 200 VAC input)Rated i
Omron Power Supply S8EX Series S8EX-N01548
Omron Power Supply S8EX Series S8EX-N01548
Open type , Input 100 to 240 VAC , 15W , Output 48V 0.32APower rating 15 WEfficiency 83% Min. ï¼ˆAt 100 VAC input)82% Min. ï¼ˆAt 200 VAC input)Rated inp
Omron Power Supply S8JX Switch Mode Power S8JX-P10024D
Omron Power Supply S8JX Switch Mode Power S8JX-P10024D
Open-Frame Type , Input 100 to 240 VAC , 100W , Output 24V 4.5A , DIN Rail mounting typePower rating 100 WEfficiency 81% Min.Rated input voltage 100 to 240 VACAllowable-i