Omron Power Supply S8TX Series S8TS-06024-E1

Omron Power Supply S8TX Series S8TS-06024-E1
share

Basic Block , Screw Terminal , Input 100 to 240 VAC , Output 24 V 2.5 A
Power rating 60 W
Efficiency 80% TYP. ï¼ˆAt rated input, 100% load)
Rated input voltage 100 to 240 VAC
Allowable-input voltage variable range 85 to 264 VAC80 to 370 VDC
Note at DC input The range for compliance with EC Directives and safety standards (UL, EN, etc.) is 100 to 240 VAC (85 to 264 VAC).
Frequency 50/60 Hz (47 to 63 Hz Single-phase)
Rated input current 1.0 A Max. ï¼ˆAt 100 VAC input)0.5 A Max. ï¼ˆAt 200 VAC input)
Power factor 0.9 Min. (At rated input, 100% load)
Harmonic Current EN61000-3-2
Leakage current 0.35 mA Max. (At 100 VAC input)0.7 mA Max. (At 240 VAC input)
Inrush current 17.5 A Max. ï¼ˆAt 100 VAC input (For cold start at 25 CEL))35 A Max. ï¼ˆAt 200 VAC input (For cold start at 25 CEL))
Rated output voltage 24 VDC
Output voltage variable range 22 to 28 V (With V. ADJ)
Ripple 2%(p-p) Max. (Under the rated I/O conditions.)
Static input variation influence 0.5% Max. (At 85 to 264 VAC input, 100% load)
Static load variation influence 3.5% Max. (Single operation, 0 to 100% load)2% Max. (Single operation, 10 to 100% load)5.5% Max. (Parallel operation, 0 to 100% load)3% Max. (Parallel operation, 10 to 100% load)
Ambient temperature variation influence 0.05 %/CEL Max.
Rated output current 2.5 A
Start up time 1000 ms Max. ï¼ˆ100/200 VAC, rated input)
Hold time 20 ms Min. (100/200 VAC, rated input)
Overload protection 105% to 140% of the rated output current (Single operation), 100% to 140% of the rated output current (Parallel operation)Inverted L voltage drop, Automatic reset
Overvoltage protection Operated at 120 to 145 % of the rated output voltage, Shut-offResetting: Reset the power by turning it back (OFF time: at least 1 min)
Maintenance forecast monitor output No
Total run time monitor output No
Undervoltage alarm output Yes (open collector output), 30 VDC Max., 50 mA Max.
Parallel operation Yes (Up to 4 Blocks)
N+1 redundant system Yes (Up to 5 Blocks)
Series operation Yes
Applicable standard (UL) Standard No.: UL508 (Listing, Class 2: Per UL1310), UL UR: UL60950-1 (Recognition)
Applicable standard (CSA) Standard No.: cUL Listed: CSA C22.2 No.107.1 (Class 2: Per No.223), cUR: CSA C22.2 No.60950-1
Applicable standard (EN) Standard No.: EN50178, EN60950-1
Applicable standard (EC Directive (EMI)) EMI: EN61204-3Emission Enclosure: Conforms to EN61204-3 Class BEmission AC mains: Conforms to EN61204-3 Class B and based on FCC Class AEMS: EN61204-3
Applicable standard(VDE) Standard No.: VDE0160, VDE0805 Teil 1 File number:
Ambient temperature Operating: -10 to 60 CELStorage: -25 to 65 CEL(with no icing or condensation)
Ambient humidity Operating: 25 to 85% RHStorage: 25 to 90% RH(With no condensation)
Dielectric strength Between all inputs and all outputs: 3 kVAC for 1 min (Detection current: 20 mA)Between all inputs and PE terminals: 2 kVAC for 1 min (Detection current: 20 mA)Between all outputs and PE terminals: 1 kVAC for 1 min (Detection current: 20 mA)
Insulation resistance Between all outputs and all inputs/ PE terminals: 100 MOhm Min. (at 500 VDC)
Vibration resistance 10 to 55 Hz, 0.375 mm single amplitude in each 3 directions for 2 hours
Shock resistance 150 m/s**2, in each 6 directions 3 times
Output indicator Yes (color: green)
Heat radiation Natural air-cooling
Construction Covered type
Structure Screw terminals
Mounting type DIN Rail mounting type
Attachment Bus Line Connector
Weight 450 g Max.

Omron Power Supply S8JX Switch Mode Power S8JX-P10012D
Omron Power Supply S8JX Switch Mode Power S8JX-P10012D
Open-Frame Type , Input 100 to 240 VAC , 100W , Output 12V 8.5A , DIN Rail mounting typePower rating 100 WEfficiency 78% Min.Rated input voltage 100 to 240 VACAllowable-i
Omron Power Supply S8VS Series S8VS-09024A-F
Omron Power Supply S8VS Series S8VS-09024A-F
Total Run Time Monitor , Input 100 to 240 VAC , 90 W , Output 24 V 3.75 APower rating 90 WEfficiency 83% TYP. ï¼ˆAt 100 VAC input)85% TYP. ï¼ˆAt 200 
Omron Power Supply S8JX Switch Mode Power S8JX-P10024CD
Omron Power Supply S8JX Switch Mode Power S8JX-P10024CD
Covered type , Input 100 to 240 VAC , 100W , Output 24V 4.5A , DIN Rail mounting typePower rating 100 WEfficiency 81% Min.Rated input voltage 100 to 240 VACAllowable-inpu
Omron Power Supply S8VM Series S8VM-01505CD
Omron Power Supply S8VM Series S8VM-01505CD
Standard Type , Covered Type , DIN Rail Mounting Bracket Type , Input 100 to 240 VAC , 15 W , Output 5 V 3 APower rating 15 WEfficiency 75% Min.Rated input
Omron S8JX Switch Mode Power S8JX-G01548
Omron S8JX Switch Mode Power S8JX-G01548
Open-Frame Type , Input 100 to 240 VAC , 15W , Output 48V 0.35A , Front-mounting typeAs of November 15, 2012Power rating 15 WEfficiency 68% Min.Rated input voltage 100 to
Omron Power Supply S8VS Series S8VS-03005
Omron Power Supply S8VS Series S8VS-03005
Total Run Time Monitor , Input 100 to 240 VAC , 120 W , Output 24 V 5 APower rating 120 WEfficiency 83% TYP. ï¼ˆAt 100 VAC input)85% TYP. ï¼ˆAt 200 V
Omron Power Supply S8JX Switch Mode Power S8JX-G10012C
Omron Power Supply S8JX Switch Mode Power S8JX-G10012C
Covered type , Input 100 to 240 VAC , 100 W , Output 12 V 8.5 A , Front-mounting typePower rating 100 WEfficiency 81% Min.Rated input voltage 100 to 240 VACAllowable
Omron Power Supply S8VS Series S8VS-06024A-F
Omron Power Supply S8VS Series S8VS-06024A-F
Maintenance Forecast Monitor Type , Input 100 to 240 VAC , 120 W , Output 24 V 5 APower rating 120 WEfficiency 83% TYP. ï¼ˆAt 100 VAC input)85% TYP. ï¼ˆAt 
Omron Power Supply S8VS Series S8VS-18024A
Omron Power Supply S8VS Series S8VS-18024A
Maintenance Forecast Monitor Type , Input 100 to 240 VAC , 180 W , Output 24 V 7.5 APower rating 180 WEfficiency 85% TYP. ï¼ˆAt 100 VAC input)87% TYP. ï¼ˆAt&nb
Omron Power Supply S8JX Switch Mode Power S8JX-G10048CD
Omron Power Supply S8JX Switch Mode Power S8JX-G10048CD
Covered type , Input 100 to 240 VAC , 100 W , Output 48 V 2.1 A , DIN Rail mounting typePower rating 100 WEfficiency 83% Min.Rated input voltage 100 to 240