Omron Power Supply S8JX Switch Mode Power S8JX-P10024D

Omron Power Supply S8JX Switch Mode Power S8JX-P10024D
share

Open-Frame Type , Input 100 to 240 VAC , 100W , Output 24V 4.5A , DIN Rail mounting type
Power rating 100 W
Efficiency 81% Min.
Rated input voltage 100 to 240 VAC
Allowable-input voltage variable range 85 to 264 VAC80 to 370 VDC
Note at DC input The range for compliance with EC Directives and safety standards (UL, EN, etc.) is 100 to 240 VAC (85 to 264 VAC).
Frequency 50/60 Hz (47 to 63 Hz Single-phase)
Rated input current 1.4 A Max. ï¼ˆAt 100 VAC input)0.75 A Max. ï¼ˆAt 200 VAC input)
Power factor 0.9 Min.
Harmonic Current EN61000-3-2
Leakage current 0.5 mA Max. (At 100 VAC input)1 mA Max. (At 200 VAC input)
Inrush current 17.5 A Max. ï¼ˆAt 100 VAC input (For cold start at 25 CEL))35 A Max. ï¼ˆAt 200 VAC input (For cold start at 25 CEL))
Rated output voltage 24 VDC
Output voltage variable range -10 to +15% (With V. ADJ)(If the output voltage adjuster (V. ADJ) is turned, the voltage will increase by more than the allowable voltage range. When adjusting the output voltage, confirm the actual output voltage from the Power Supply and be sure that load is not damaged.)
Ripple 2%(p-p) Max. (Under the rated I/O conditions.)
Static input variation influence 0.4% Max. (with AC input voltage)
Static load variation influence 0.8% Max. (At rated input, 0 to 100% load)
Ambient temperature variation influence 0.05 %/CEL Max. (At rated input/output voltage)
Rated output current 4.5 A
Start up time 1000 ms Max.
Hold time 20 ms Min. (At rated input voltage: 100 or 200 VAC at 100% load.)
Overload protection 105% to 160% of the rated output currentVoltage drop, Automatic reset
Overvoltage protection Operated at 130% Min. of the rated output voltage, Shut-offResetting: Reset the power by turning it back (OFF time: at least 3 min)
Overheat protection No
Parallel operation No (However, backup operation is possible; external diodes required.)
Series operation Yes (Up to 2 Power Supplies with external diode)
Applicable standard (UL) Standard No.: UL Listed: UL508 (Listing), UL UR: UL60950-1 (Recognition)
Applicable standard (CSA) Standard No.: cUL Listed: CSA C22.2 No.107.1, cUR: CSA C22.2 No.60950-1
Applicable standard (EN) Standard No.: EN50178, EN60950-1
Applicable standard (EC Directive (EMI)) Emission Enclosure: Conforms to EN55011 Group 1 Class BEmission AC mains: Conforms to EN55011 Group 1 Class B and based on FCC Class B
Applicable standard(VDE) Standard No.: VDE0160, VDE0805 Teil 1 File number:
Applicable standard(SEMI) F47-0706 (200 VAC input)
Applicable standard(Other) Conformed standard 2: Terminal block: Based on DIN EN50274 (VDE0660-514)
Ambient temperature Operating: -10 to 70 CELStorage: -25 to 75 CEL(with no icing or condensation)
Ambient humidity Operating: 25 to 85%Storage: 25 to 90%(With no icing or condensation)
Dielectric strength Between all inputs and all outputs: 3 kVAC for 1 min (Detection current: 20 mA)Between all inputs and PE terminals: 2 kVAC for 1 min (Detection current: 20 mA)Between all outputs and PE terminals: 1 kVAC for 1 min (Detection current: 20 mA)
Insulation resistance Between all outputs and all inputs/ PE terminals: 100 MOhm Min. (at 500 VDC)
Vibration resistance 10 to 55 Hz, 0.375 mm single amplitude in each 3 directions for 2 hours
Shock resistance 150 m/s**2, in each 6 directions 3 times
Heat radiation Natural air-cooling
Construction Open-frame type
Terminal type Screw terminal
Mounting type DIN Rail mounting type

Omron S8JX Switch Mode Power S8JX-G05012CD
Omron S8JX Switch Mode Power S8JX-G05012CD
Covered type , Input 100 to 240 VAC , 50 W , Output 12 V 4.2 A , DIN Rail mounting typePower rating 50 WEfficiency 81% Min.Rated input voltage 100 to 240 V
Omron Power Supply S8VM Series S8VM-05012
Omron Power Supply S8VM Series S8VM-05012
Standard Type , Open-Frame Type , Bottom Mounting Type , Input 100 to 240 VAC , 50 W , Output 12 V 4.3 APower rating 50 WEfficiency 79% Min.Rated input voltage
Omron Power Supply S8EX Series S8EX-N03015
Omron Power Supply S8EX Series S8EX-N03015
Open type , Input 100 to 240 VAC , 30W , Output 15V 2APower rating 30 WEfficiency 83% Min. ï¼ˆAt 100 VAC input)83% Min. ï¼ˆAt 200 VAC input)Rated input&
Omron S8JX Switch Mode Power S8JX-P10005D
Omron S8JX Switch Mode Power S8JX-P10005D
Open-Frame Type , Input 100 to 240 VAC , 100W , Output 5V 20A , DIN Rail mounting typePower rating 100 WEfficiency 78% Min.Rated input voltage 100 to 240 VACAllowable-inp
Omron S8JX Switch Mode Power S8JX-G05012D
Omron S8JX Switch Mode Power S8JX-G05012D
Open-Frame Type , Input 100 to 240 VAC , 50W , Output 12V 4.2A , DIN Rail mounting typePower rating 50 WEfficiency 81% Min.Rated input voltage 100 to 240 VACAllowable-inp
Omron Power Supply S8VM Series S8VM-03015C
Omron Power Supply S8VM Series S8VM-03015C
Standard Type , Covered Type , Bottom Mounting Type , Input 100 to 240 VAC , 30 W , Output 15 V 2 APower rating 30 WEfficiency 79% Min.Rated input voltage 100&n
Omron Power Supply S8JX Switch Mode Power S8JX-G10048C
Omron Power Supply S8JX Switch Mode Power S8JX-G10048C
Covered type , Input 100 to 240 VAC , 100 W , Output 48 V 2.1 A , Front-mounting typePower rating 100 WEfficiency 83% Min.Rated input voltage 100 to 240 VACAllowable
Omron S8JX Switch Mode Power S8JX-G03548C
Omron S8JX Switch Mode Power S8JX-G03548C
Covered type , Input 100 to 240 VAC , 35 W , Output 48 V 0.75 A , Front-mounting typePower rating 35 WEfficiency 73% Min.Rated input voltage 100 to 240 VACAllowable-
Omron Power Supply S8VM Series S8VM-10012C
Omron Power Supply S8VM Series S8VM-10012C
Standard Type , Covered Type , Bottom Mounting Type , Input 100 to 240 VAC , 100 W , Output 12 V 8.5 APower rating 100 WEfficiency 81% Min.Rated input voltage 1
Omron Power Supply S8JX Switch Mode Power S8JX-P15005C
Omron Power Supply S8JX Switch Mode Power S8JX-P15005C
Covered type , Input 100 to 240 VAC , 150W , Output 5V 30A , Front-mounting typePower rating 150 WEfficiency 79% Min.Rated input voltage 100 to 240 VACAllowable-input voltage&