Total Run Time Monitor , Input 100 to 240 VAC , 90 W , Output 24 V 3.75 A , With Undervoltage Alarm (Ttransistor (Sourcing))
Power rating 90 W
Efficiency 83% TYP. ï¼ˆAt 100 VAC input)85% TYP. ï¼ˆAt 200 VAC input)
Rated input voltage 100 to 240 VAC
Allowable-input voltage variable range 85 to 264 VAC80 to 370 VDC
Note at DC input The range for compliance with EC Directives and safety standards (UL, EN, etc.) is 100 to 240 VAC (85 to 264 VAC).
Frequency 50/60 Hz (47 to 450 Hz Single-phase)
Rated input current 1.9 A TYP. ï¼ˆAt 100 VAC input)1.2 A TYP. ï¼ˆAt 200 VAC input)
Harmonic Current EN61000-3-2
Leakage current 0.5 mA Max. (At 100 VAC input)1.0 mA Max. (At 200 VAC input)
Inrush current 14 A TYP. ï¼ˆAt 100 VAC input (For cold start at 25 CEL))28 A TYP. ï¼ˆAt 200 VAC input (For cold start at 25 CEL))
Rated output voltage 24 VDC
Ripple 2%(p-p) Max. (Under the rated I/O conditions.)150 mV Max. (Under the rated I/O conditions.)
Static input variation influence 0.5% Max. (At 85 to 264 VAC input, 100% load)
Static load variation influence 1.5% Max. (At rated input, 0 to 100% load)
Ambient temperature variation influence 0.05 %/CEL Max.
Rated output current 3.75 A
Start up time 660 ms TYP. ï¼ˆ100 VAC input)420 ms TYP. ï¼ˆ200 VAC input)
Hold time 28 ms TYP. ï¼ˆ100 VAC input)136 ms TYP. ï¼ˆ200 VAC input)
Overload protection 105% to 160% of the rated output currentInverted L voltage drop, Intermittent operation, Automatic reset
Overvoltage protection Operated at 130% Min. of the rated output voltage, Shut-offResetting: Reset the power by turning it back (OFF time: at least 3 min)
Overheat protection No
Maintenance forecast monitor output No
Total run time monitor output Yes (open collector output), 30 VDC Max., 50 mA Max., Sourcing (PNP)
Undervoltage alarm output Yes (open collector output), 30 VDC Max., 50 mA Max., Sourcing (PNP)
Power failure alarm output No
Parallel operation No (However, backup operation is possible; external diodes required.)
Series operation Yes (Up to 2 Power Supplies with external diode)
Remote sensing function No
Applicable standard (UL) Standard No.: UL Listed: UL508 (Listing, Class 2: Per UL1310), UL UR: UL60950-1 (Recognition)
Applicable standard (CSA) Standard No.: cUL: CSA C22.2 No.107.1 (Class 2: Per No.223), cUR: CSA C22.2 No.60950-1
Applicable standard (EN) Standard No.: EN50178, EN60950-1
Applicable standard (EC Directive (EMI)) Emission Enclosure: Conforms to EN61204-3 Class AEmission AC mains: Conforms to EN61204-3 Class A and based on FCC Class AEMS: EN61204-3 High severity levels
Applicable standard(VDE) Standard No.: VDE0160, VDE0805 Teil 1 File number:
Applicable standard(SEMI) F47-0200 (200 VAC input)
Ambient temperature Operating: -10 to 60 CELStorage: -25 to 65 CEL(with no icing or condensation)
Ambient humidity Operating: 25 to 85%Storage: 25 to 90%(With no icing or condensation)
Dielectric strength Between all inputs and all outputs/alarm outputs: 3 kVAC for 1 min (Detection current: 20 mA)Between all inputs and PE terminals: 2 kVAC for 1 min (Detection current: 20 mA)Between all outputs/alarm outputs and all PE terminals: 1 kVAC for 1 min (Detection current: 20 mA)Between all outputs and all alarm outputs: 500 VAC for 1 min (Detection current: 20 mA)
Insulation resistance Between all outputs/alarm outputs and all inputs/PE terminals: 100 MOhm Min. (at 500 VDC)
Vibration resistance 10 to 55 Hz, 0.375 mm single amplitude in each 3 directions for 2 hours
Shock resistance 150 m/s**2, in each 6 directions 3 times
Output indicator Yes (color: green)
Heat radiation Natural air-cooling
Construction Covered type
Terminal type Screwless terminal
Mounting type DIN Rail mounting type
Weight 490 g Max.

Omron Power Supply S8VS Series S8VS-12024-F
Omron Power Supply S8VS Series S8VS-12024-F
Standard Model , Input 100 to 240 VAC , 120 W , Output 24 V 5 A , Screwless Terminal BlockPower rating 120 WEfficiency 84% TYP. ï¼ˆAt 100 VAC input)87% TYP.&
Omron Power Supply S8VS Series S8VS-24024A
Omron Power Supply S8VS Series S8VS-24024A
Maintenance Forecast Monitor Type , Input 100 to 240 VAC , 240 W , Output 24 V 10 APower rating 240 WEfficiency 85% TYP. ï¼ˆAt 100 VAC input)88% TYP. ï¼ˆAt&nbs
Omron Power Supply S8VS Series S8VS-09024BPS-F
Omron Power Supply S8VS Series S8VS-09024BPS-F
Maintenance Forecast Monitor Type , Input 100 to 240 VAC , 90 W , Output 24 V 3.75 A , With Undervoltage Alarm (Ttransistor (Sourcing))Power rating 90 WEfficiency 83%&nbs
Omron Power Supply S8VM Series S8VM-01512D
Omron Power Supply S8VM Series S8VM-01512D
Standard Type , Open-Frame Type , DIN Rail Mounting Bracket Type , Input 100 to 240 VAC , 15 W , Output 12 V 1.3 APower rating 15 WEfficiency 78% Min.Rated 
Omron Power Supply S8EX Series S8EX-N03015
Omron Power Supply S8EX Series S8EX-N03015
Open type , Input 100 to 240 VAC , 30W , Output 15V 2APower rating 30 WEfficiency 83% Min. ï¼ˆAt 100 VAC input)83% Min. ï¼ˆAt 200 VAC input)Rated input&
Omron Power Supply S8VM Series S8VM-10012D
Omron Power Supply S8VM Series S8VM-10012D
Standard Type , Open-Frame Type , DIN Rail Mounting Bracket Type , Input 100 to 240 VAC , 100 W , Output 12 V 8.5 APower rating 100 WEfficiency 81% Min.Rated&nb
Omron Power Supply S8VM Series S8VM-01524
Omron Power Supply S8VM Series S8VM-01524
Standard Type , Open-Frame Type , Bottom Mounting Type , Input 100 to 240 VAC , 15 W , Output 24 V 0.65 APower rating 15 WEfficiency 80% Min.Rated input voltage
Omron Power Supply S8VS Series S8VS-01524
Omron Power Supply S8VS Series S8VS-01524
Total Run Time Monitor , Input 100 to 240 VAC , 120 W , Output 24 V 5 APower rating 120 WEfficiency 83% TYP. ï¼ˆAt 100 VAC input)85% TYP. ï¼ˆAt 200 V
Omron S8JX Switch Mode Power S8JX-G01548D
Omron S8JX Switch Mode Power S8JX-G01548D
Open-Frame Type , Input 100 to 240 VAC , 15W , Output 48V 0.35A , DIN Rail mounting typeAs of November 15, 2012Power rating 15 WEfficiency 68% Min.Rated input voltag
Omron S8JX Switch Mode Power S8JX-G01512
Omron S8JX Switch Mode Power S8JX-G01512
Open-Frame Type , Input 100 to 240 VAC , 15W , Output 12V 1.3A , Front-mounting typePower rating 15 WEfficiency 68% Min.Rated input voltage 100 to 240 VACAllowable-input volta