Total Run Time Monitor , Input 100 to 240 VAC , 90 W , Output 24 V 3.75 A
Power rating 90 W
Efficiency 83% TYP. Ã¯Â¼Ë†At 100 VAC input)85% TYP. Ã¯Â¼Ë†At 200 VAC input)
Rated input voltage 100 to 240 VAC
Allowable-input voltage variable range 85 to 264 VAC80 to 370 VDC
Note at DC input The range for compliance with EC Directives and safety standards (UL, EN, etc.) is 100 to 240 VAC (85 to 264 VAC).
Frequency 50/60 Hz (47 to 450 Hz Single-phase)
Rated input current 1.9 A TYP. Ã¯Â¼Ë†At 100 VAC input)1.2 A TYP. Ã¯Â¼Ë†At 200 VAC input)
Harmonic Current EN61000-3-2
Leakage current 0.5 mA Max. (At 100 VAC input)1.0 mA Max. (At 200 VAC input)
Inrush current 14 A TYP. Ã¯Â¼Ë†At 100 VAC input (For cold start at 25 CEL))28 A TYP. Ã¯Â¼Ë†At 200 VAC input (For cold start at 25 CEL))
Rated output voltage 24 VDC
Ripple 2%(p-p) Max. (Under the rated I/O conditions.)150 mV Max. (Under the rated I/O conditions.)
Static input variation influence 0.5% Max. (At 85 to 264 VAC input, 100% load)
Static load variation influence 1.5% Max. (At rated input, 0 to 100% load)
Ambient temperature variation influence 0.05 %/CEL Max.
Rated output current 3.75 A
Start up time 660 ms TYP. Ã¯Â¼Ë†100 VAC input)420 ms TYP. Ã¯Â¼Ë†200 VAC input)
Hold time 28 ms TYP. Ã¯Â¼Ë†100 VAC input)136 ms TYP. Ã¯Â¼Ë†200 VAC input)
Overload protection 105% to 160% of the rated output currentInverted L voltage drop, Intermittent operation, Automatic reset
Overvoltage protection Operated at 130% Min. of the rated output voltage, Shut-offResetting: Reset the power by turning it back (OFF time: at least 3 min)
Overheat protection No
Maintenance forecast monitor output No
Total run time monitor output No
Undervoltage alarm output No
Power failure alarm output No
Parallel operation No (However, backup operation is possible; external diodes required.)
Series operation Yes (Up to 2 Power Supplies with external diode)
Remote sensing function No
Applicable standard (UL) Standard No.: UL Listed: UL508 (Listing, Class 2: Per UL1310), UL UR: UL60950-1 (Recognition)
Applicable standard (CSA) Standard No.: cUL: CSA C22.2 No.107.1 (Class 2: Per No.223), cUR: CSA C22.2 No.60950-1
Applicable standard (EN) Standard No.: EN50178, EN60950-1
Applicable standard (EC Directive (EMI)) Emission Enclosure: Conforms to EN61204-3 Class AEmission AC mains: Conforms to EN61204-3 Class A and based on FCC Class AEMS: EN61204-3 High severity levels
Applicable standard(VDE) Standard No.: VDE0160, VDE0805 Teil 1 File number:
Applicable standard(SEMI) F47-0200 (200 VAC input)
Ambient temperature Operating: -10 to 60 CELStorage: -25 to 65 CEL(with no icing or condensation)
Ambient humidity Operating: 25 to 85%Storage: 25 to 90%(With no icing or condensation)
Dielectric strength Between all inputs and all outputs/alarm outputs: 3 kVAC for 1 min (Detection current: 20 mA)Between all inputs and PE terminals: 2 kVAC for 1 min (Detection current: 20 mA)Between all outputs/alarm outputs and all PE terminals: 1 kVAC for 1 min (Detection current: 20 mA)Between all outputs and all alarm outputs: 500 VAC for 1 min (Detection current: 20 mA)
Insulation resistance Between all outputs/alarm outputs and all inputs/PE terminals: 100 MOhm Min. (at 500 VDC)
Vibration resistance 10 to 55 Hz, 0.375 mm single amplitude in each 3 directions for 2 hours
Shock resistance 150 m/s**2, in each 6 directions 3 times
Output indicator Yes (color: green)
Heat radiation Natural air-cooling
Construction Covered type
Terminal type Screwless terminal
Mounting type DIN Rail mounting type
Weight 490 g Max.

Omron Power Supply S8VM Series S8VM-03012
Omron Power Supply S8VM Series S8VM-03012
Standard Type , Open-Frame Type , Bottom Mounting Type , Input 100 to 240 VAC , 30 W , Output 12 V 2.5 APower rating 30 WEfficiency 79% Min.Rated input voltage
Omron Power Supply S8EX Series S8EX-BP15024LC
Omron Power Supply S8EX Series S8EX-BP15024LC
With chassis and cover , Input 100 to 240 VAC , 150W , Output 24V 6.3APower rating 150 WEfficiency 84% Min. Ã¯Â¼Ë†At 100 VAC input)87% Min. Ã¯Â¼Ë†At 200 VAC in
Omron Power Supply S8VS Series S8VS-18024B-F
Omron Power Supply S8VS Series S8VS-18024B-F
Total Run Time Monitor , Input 100 to 240 VAC , 180 W , Output 24 V 7.5 APower rating 180 WEfficiency 85% TYP. Ã¯Â¼Ë†At 100 VAC input)87% TYP. Ã¯Â¼Ë†At 200 
Omron Power Supply S8VM Series S8VM-01505C
Omron Power Supply S8VM Series S8VM-01505C
Standard Type , Covered Type , Bottom Mounting Type , Input 100 to 240 VAC , 15 W , Output 5 V 3 APower rating 15 WEfficiency 75% Min.Rated input voltage 100&nb
Omron Power Supply S8VS Series S8VS-12024B-F
Omron Power Supply S8VS Series S8VS-12024B-F
Standard Model , Input 100 to 240 VAC , 15 W , Output 24 V 0.65 APower rating 15 WEfficiency 83% TYP. Ã¯Â¼Ë†At 100 VAC input)80% TYP. Ã¯Â¼Ë†At 200 VAC input)Rat
Omron Power Supply S8VS Series S8VS-48024A-F
Omron Power Supply S8VS Series S8VS-48024A-F
Maintenance Forecast Monitor Type , Input 100 to 240 VAC , 480 W , Output 24 V 20 A , Screwless Terminal BlockPower rating 480 WEfficiency 85% TYP. Ã¯Â¼Ë†At 100 
Omron Power Supply S8EX Series S8EX-BP15048L
Omron Power Supply S8EX Series S8EX-BP15048L
With chassis , Input 100 to 240 VAC , 150W , Output 48V 3.2APower rating 150 WEfficiency 85% Min. Ã¯Â¼Ë†At 100 VAC input)88% Min. Ã¯Â¼Ë†At 200 VAC input)Rated 
Omron Power Supply S8VS Series S8VS-48024B
Omron Power Supply S8VS Series S8VS-48024B
Total Run TimeMonitor , Input 100 to 240 VAC , 480 W , Output 24 V 20 APower rating 480 WEfficiency 85% TYP. Ã¯Â¼Ë†At 100 VAC input)89% TYP. Ã¯Â¼Ë†At 200 VAC&nb
Omron Power Supply S8EX Series S8EX-N03015L
Omron Power Supply S8EX Series S8EX-N03015L
With chassis and cover , Input 100 to 240 VAC , 30W , Output 15V 2APower rating 30 WEfficiency 83% Min. Ã¯Â¼Ë†At 100 VAC input)83% Min. Ã¯Â¼Ë†At 200 VAC inputÃ
Omron Power Supply S8VS Series S8VS-48024A
Omron Power Supply S8VS Series S8VS-48024A
Maintenance Forecast Monitor Type , Input 100 to 240 VAC , 480 W , Output 24 V 20 APower rating 480 WEfficiency 85% TYP. Ã¯Â¼Ë†At 100 VAC input)89% TYP. Ã¯Â¼Ë†At&nbs