Omron Power Supply S8JX Switch Mode Power S8JX-G10005CD-Power Supply, Battery and Inverter
 
Cart()
 
 
Categories
Contact Us
  • A&S Power Supply Co.,Ltd
  • Address:469, Xinsheng Road, Gaoxin District, Chengdu, Sichuan, China
  • Tel:+86-28-65376776
  • Fax:+86-28-86129221
  • Email:inverter@electrical8.com
  • Contact Person:Karina
Home / Products / power supply / Omron Power Supply / S8JX Switch Mode Power / Omron Power Supply S8JX Switch Mode Power S8JX-G10005CD

Omron Power Supply S8JX Switch Mode Power S8JX-G10005CD

Omron Power Supply S8JX Switch Mode Power S8JX-G10005CD
share

Covered type , Input 100 to 240 VAC , 100 W , Output 5 V 20 A , DIN Rail mounting type
Power rating 100 W
Efficiency 76% Min.
Rated input voltage 100 to 240 VAC
Allowable-input voltage variable range 85 to 264 VAC80 to 370 VDC
Note at DC input The range for compliance with EC Directives and safety standards (UL, EN, etc.) is 100 to 240 VAC (85 to 264 VAC).
Frequency 50/60 Hz (47 to 450 Hz Single-phase)
Rated input current 2.5 A Max. Ã¯Â¼Ë†At 100 VAC input)1.5 A Max. Ã¯Â¼Ë†At 200 VAC input)
Leakage current 0.5 mA Max. (At 100 VAC input)1 mA Max. (At 200 VAC input)
Inrush current 20 A Max. Ã¯Â¼Ë†At 100 VAC input (For cold start at 25 CEL))40 A Max. Ã¯Â¼Ë†At 200 VAC input (For cold start at 25 CEL))
Rated output voltage 5 VDC
Output voltage variable range -10 to +15% (With V. ADJ)(If the output voltage adjuster (V. ADJ) is turned, the voltage will increase by more than the allowable voltage range. When adjusting the output voltage, confirm the actual output voltage from the Power Supply and be sure that load is not damaged.)
Ripple 2%(p-p) Max. (Under the rated I/O conditions.)
Static input variation influence 0.4% Max. (with AC input voltage)
Static load variation influence 0.8% Max. (At rated input, 0 to 100% load)
Ambient temperature variation influence 0.05 %/CEL Max. (At rated input/output voltage)
Rated output current 20 A
Start up time 500 ms Max. Ã¯Â¼Ë†Up to 90% of output voltage at rated input and output)
Hold time 20 ms Min. (At rated input voltage: 100 or 200 VAC at 100% load.)
Overload protection 105% to 175% of the rated output currentVoltage drop, Intermittent operation, Automatic reset
Overvoltage protection Operated at 120 to 140 % of the rated output voltage, Shut-offResetting: Reset the power by turning it back (OFF time: at least 7 min)
Overheat protection No
Maintenance forecast monitor output No
Total run time monitor output No
Undervoltage alarm output No
Power failure alarm output No
Parallel operation No (However, backup operation is possible; external diodes required.)
Series operation Yes (Up to 2 Power Supplies with external diode)
Remote sensing function No
Applicable standard (UL) Standard No.: UL Listed: UL508 (Listing), UL UR: UL60950-1 (Recognition)
Applicable standard (CSA) Standard No.: cUL Listed: CSA C22.2 No.107.1, cUR: CSA C22.2 No.60950-1
Applicable standard (EN) Standard No.: EN50178, EN60950-1
Applicable standard (EC Directive (EMI)) Emission Enclosure: Conforms to EN55011 Group 1 Class AEmission AC mains: Conforms to EN55011 Group 1 Class A and based on FCC Class AEMS: EN61204-3 High severity levels
Applicable standard(VDE) Standard No.: VDE0160, VDE0805 Teil 1 File number:
Applicable standard(SEMI) F47-0200 (200 VAC input)
Applicable standard(Other) Conformed standard 2: Terminal block: Based on DIN EN50274 (VDE0660-514)
Ambient temperature Operating: -10 to 60 CELStorage: -25 to 65 CEL(with no icing or condensation)
Ambient humidity Operating: 25 to 85%Storage: 25 to 90%(With no icing or condensation)
Dielectric strength Between all inputs and all outputs: 3 kVAC for 1 min (Detection current: 20 mA)Between all inputs and PE terminals: 2 kVAC for 1 min (Detection current: 20 mA)Between all outputs and PE terminals: 1 kVAC for 1 min (Detection current: 20 mA)
Insulation resistance Between all outputs and all inputs/ PE terminals: 100 MOhm Min. (at 500 VDC)
Vibration resistance 10 to 55 Hz, 0.375 mm single amplitude in each 3 directions for 2 hours
Shock resistance 150 m/s**2, in each 6 directions 3 times
Output indicator Yes (color: green)
Heat radiation Natural air-cooling
Construction Covered type
Terminal type Screw terminal
Mounting type DIN Rail mounting type
Weight 710 g Max.

Omron Power Supply S8EX Series S8EX-N03015L
Omron Power Supply S8EX Series S8EX-N03015L
With chassis and cover , Input 100 to 240 VAC , 30W , Output 15V 2APower rating 30 WEfficiency 83% Min. Ã¯Â¼Ë†At 100 VAC input)83% Min. Ã¯Â¼Ë†At 200 VAC inputÃ
Omron Power Supply S8VS Series S8VS-09024BES-F
Omron Power Supply S8VS Series S8VS-09024BES-F
Total Run Time Monitor , Input 100 to 240 VAC , 90 W , Output 24 V 3.75 APower rating 90 WEfficiency 83% TYP. Ã¯Â¼Ë†At 100 VAC input)85% TYP. Ã¯Â¼Ë†At 200 
Omron Power Supply S8EX Series S8EX-P10005L
Omron Power Supply S8EX Series S8EX-P10005L
With chassis , Input 100 to 240 VAC , 100W , Output 5V 20APower rating 100 WEfficiency 81% Min. Ã¯Â¼Ë†At 100 VAC input)84% Min. Ã¯Â¼Ë†At 200 VAC input)Rated i
Omron Power Supply S8JX Switch Mode Power S8JX-P60005C
Omron Power Supply S8JX Switch Mode Power S8JX-P60005C
Covered type , Input 100 to 240 VAC , 600W , Output 5V 120A , Front-mounting typePower rating 600 WEfficiency 76% Min.Rated input voltage 100 to 240 VACAllowable-input voltage
Omron Power Supply S8JX Switch Mode Power S8JX-P30048C
Omron Power Supply S8JX Switch Mode Power S8JX-P30048C
Covered type , Input 100 to 240 VAC , 300W , Output 48V 7A , Front-mounting typePower rating 300 WEfficiency 78% Min.Rated input voltage 100 to 240 VACAllowable-input voltage&
Omron Power Supply S8VM Series S8VM-10015CD
Omron Power Supply S8VM Series S8VM-10015CD
Standard Type , Covered Type , DIN Rail Mounting Bracket Type , Input 100 to 240 VAC , 100 W , Output 15 V 7 APower rating 100 WEfficiency 81% Min.Rated in
Omron Power Supply S8VS Series S8VS-48024A
Omron Power Supply S8VS Series S8VS-48024A
Maintenance Forecast Monitor Type , Input 100 to 240 VAC , 480 W , Output 24 V 20 APower rating 480 WEfficiency 85% TYP. Ã¯Â¼Ë†At 100 VAC input)89% TYP. Ã¯Â¼Ë†At&nbs
Omron Power Supply S8VM Series S8VM-03024
Omron Power Supply S8VM Series S8VM-03024
Standard Type , Open-Frame Type , Bottom Mounting Type , Input 100 to 240 VAC , 30 W , Output 24 V 1.3 APower rating 30 WEfficiency 81% Min.Rated input voltage
Omron Power Supply S8EX Series S8EX-N01512LC
Omron Power Supply S8EX Series S8EX-N01512LC
With chassis and cover , Input 100 to 240 VAC , 15W , Output 12V 1.3APower rating 15 WEfficiency 77% Min. Ã¯Â¼Ë†At 100 VAC input)77% Min. Ã¯Â¼Ë†At 200 VAC inpu
Omron S8JX Switch Mode Power S8JX-G05048C
Omron S8JX Switch Mode Power S8JX-G05048C
Covered type , Input 100 to 240 VAC , 50 W , Output 48 V 1.1 A , Front-mounting typePower rating 50 WEfficiency 82% Min.Rated input voltage 100 to 240 VACAllowable-i