- power supply
- TDK Lambda Power Supply
- Yamaha Power Supply
- Omron Power Supply
- Plus Power Supply
- Bestec Power Supply
- Sorensen Power Supply
- Antec Power Supply
- Meanwell Power Supply
- Weidmuller Power Supply
- Hipro Power Supply
- Sparkle Power Supply
- Lenovo Power Supply
- Zippy Power Supply
- Enermax Power Supply
- Agilent Power Supply
- Phihong Power Supply
- Liteon power supply
- Acble Power Supply
- Instek Power Supply
- Zalman Power Supply
- FSP Power Supply
- Aopen Power Supply
- Spellman Supply
- Delta Supply
- Cosel Supply
- Aj`s Power Source Supply
- Coolmax Supply
- MEAN WELL Power Supply
- SENDON Power Supply
- MGE Power Supply
- UPS Power Supply
- APC UPS Power Supply
- Riello UPS Power Supply
- EATON UPS Power Supply
- SANTAK UPS Power Supply
- Siemens UPS Power Supply
- Powerware UPS Power Supply
- OMRON UPS Power Supply
- Mitsubishi UPS Power Suppply
- DELTA Uninterruptible Power Supply
- EAST UPS Power Supply
- EMERSON UPS Power Supply
- Fuji UPS Power Supply
- EFFEKTA Uninterruptible Power Supply
- Gutor UPS Power Supply
- KELONG UPS Power Supply
- LADIS Uninterruptible Power Supply
- CBC UPS Power Supply
- Phoenix UPS Power Supply
- SVC Uninterruptible Power Supply
- Avaya UPS Power Supply
- NETCCA Uninterruptible Power Supply
- battery
- inverter
- Xantrex inverter
- Samlex inverter
- Schumacher inverter
- KACO inverter
- Wagan inverter
- AIMS inverter
- Victron inverter
- Targus inverter
- Whistler inverter
- Enphase inverter
- Satcon inverter
- Sima inverter
- Kensington inverter
- Exeltech inverter
- Stanley inverter
- ABB inverter
- SMA inverter
- Hyundai inverter
- Mastervolt inverter
- YAMAHA inverter
- Belkin inverter
- Microtek inverter
- Growatt inverter
- TDK inverter
- TOSHIBA inverter
- Su kam inverter
- Omnik inverter
- Ingeteam inverter
- Samil Power inverter
- Sungrow inverter
- Cobra inverter
- Power Bright inverter
- Bestek inverter
- A&S Power Supply Co.,Ltd
- Address:469, Xinsheng Road, Gaoxin District, Chengdu, Sichuan, China
- Tel:+86-28-65376776
- Fax:+86-28-86129221
- Email:inverter@electrical8.com
- Contact Person:Karina
Omron Power Supply S8TX Series S8TS-03012-E1
Basic Block , Screw Terminal , Input 100 to 240 VAC , Output 12 V 2.5 A
Power rating 30 W
Efficiency 73% TYP. (At rated input, 100% load)
Rated input voltage 100 to 240 VAC
Allowable-input voltage variable range 85 to 264 VAC80 to 370 VDC
Note at DC input The range for compliance with EC Directives and safety standards (UL, EN, etc.) is 100 to 240 VAC (85 to 264 VAC).
Frequency 50/60 Hz (47 to 63 Hz Single-phase)
Rated input current 0.7 A Max. (At 100 VAC input)0.4 A Max. (At 200 VAC input)
Power factor 0.8 Min. (At rated input, 100% load)
Harmonic Current EN61000-3-2
Leakage current 0.35 mA Max. (At 100 VAC input)0.7 mA Max. (At 240 VAC input)
Inrush current 17.5 A Max. (At 100 VAC input (For cold start at 25 CEL))35 A Max. (At 200 VAC input (For cold start at 25 CEL))
Rated output voltage 12 VDC
Output voltage variable range -10 to +10% (With V. ADJ)(The output voltage may increase beyond the allowable voltage range (up to +10% of the rated voltage) depending on the operation of the output voltage adjuster (V.ADJ). When adjusting the output voltage, check the output voltage of the Power Supply and be sure that the load is not damaged.)
Ripple 2%(p-p) Max. (Under the rated I/O conditions.)
Static input variation influence 0.5% Max. (At 85 to 264 VAC input, 100% load)
Static load variation influence 5% Max. (Single operation, 0 to 100% load)2% Max. (Single operation, 10 to 100% load)5.5% Max. (Parallel operation, 0 to 100% load)3% Max. (Parallel operation, 10 to 100% load)
Ambient temperature variation influence 0.05 %/CEL Max.
Rated output current 2.5 A
Start up time 1000 ms Max. (100/200 VAC, rated input)
Hold time 20 ms Min. (100/200 VAC, rated input)
Overload protection 105% to 140% of the rated output current (Single operation), 100% to 140% of the rated output current (Parallel operation)Inverted L voltage drop, Automatic reset
Overvoltage protection Operated at 115 to 145 % of the rated output voltage, Shut-offResetting: Reset the power by turning it back (OFF time: at least 1 min)
Maintenance forecast monitor output No
Total run time monitor output No
Undervoltage alarm output Yes (open collector output), 30 VDC Max., 50 mA Max.
Parallel operation Yes (Up to 4 Blocks)
N+1 redundant system Yes (Up to 5 Blocks)
Series operation Yes
Applicable standard (UL) Standard No.: UL Listed: UL508 (Listing), UL UR: UL60950-1 (Recognition)
Applicable standard (CSA) Standard No.: cUL Listed: CSA C22.2 No.107.1, cUR: CSA C22.2 No.60950-1
Applicable standard (EN) Standard No.: EN50178, EN60950-1
Applicable standard (EC Directive (EMI)) EMI: EN61204-3Emission Enclosure: Conforms to EN61204-3 Class BEmission AC mains: Conforms to EN61204-3 Class B and based on FCC Class AEMS: EN61204-3
Applicable standard(VDE) Standard No.: VDE0160, VDE0805 Teil 1 File number:
Ambient temperature Operating: -10 to 60 CELStorage: -25 to 65 CEL(with no icing or condensation)
Ambient humidity Operating: 25 to 85% RHStorage: 25 to 90% RH(With no condensation)
Dielectric strength Between all inputs and all outputs: 3 kVAC for 1 min (Detection current: 20 mA)Between all inputs and PE terminals: 2 kVAC for 1 min (Detection current: 20 mA)Between all outputs and PE terminals: 1 kVAC for 1 min (Detection current: 20 mA)
Insulation resistance Between all outputs and all inputs/ PE terminals: 100 MOhm Min. (at 500 VDC)
Vibration resistance 10 to 55 Hz, 0.375 mm single amplitude in each 3 directions for 2 hours
Shock resistance 150 m/s**2, in each 6 directions 3 times
Output indicator Yes (color: green)
Heat radiation Natural air-cooling
Construction Covered type
Structure Screw terminals
Mounting type DIN Rail mounting type
Attachment Bus Line Connector
Weight 450 g Max.
Standard Model , Input 100 to 240 VAC , 15 W , Output 12 V 1.2 APower rating 15 WEfficiency 79% TYP. (At 100 VAC input)78% TYP. (At 200 VAC input)Rate
With chassis and cover , Input 100 to 240 VAC , 150W , Output 24V 6.3APower rating 150 WEfficiency 84% Min. (At 100 VAC input)87% Min. (At 200 VAC in
Covered type , Input 100 to 240 VAC , 50 W , Output 12 V 4.2 A , Front-mounting typePower rating 50 WEfficiency 81% Min.Rated input voltage 100 to 240 VACAllowable-i
Open-Frame Type , Input 100 to 240 VAC , 100W , Output 5V 20A , DIN Rail mounting typePower rating 100 WEfficiency 78% Min.Rated input voltage 100 to 240 VACAllowable-inp
Total Run Time Monitor , Input 100 to 240 VAC , 240 W , Output 24 V 10 APower rating 240 WEfficiency 85% TYP. (At 100 VAC input)88% TYP. (At 200
Covered type , Input 100 to 240 VAC , 100 W , Output 5 V 20 A , DIN Rail mounting typePower rating 100 WEfficiency 76% Min.Rated input voltage 100 to 240 V
Open-Frame Type , Input 100 to 240 VAC , 100W , Output 48V 2.1A , Front-mounting typePower rating 100 WEfficiency 83% Min.Rated input voltage 100 to 240 VACAllowable-input vol
Total Run Time Monitor , Input 100 to 240 VAC , 180 W , Output 24 V 7.5 APower rating 180 WEfficiency 85% TYP. (At 100 VAC input)87% TYP. (At 200 
Total Run Time Monitor , Input 100 to 240 VAC , 90 W , Output 24 V 3.75 A , With Undervoltage Alarm (Ttransistor (Sourcing))Power rating 90 WEfficiency 83% TYP. 
Open-Frame Type , Input 100 to 240 VAC, 150W , Output 24V 6.5A , Front-mounting typePower rating 150 WEfficiency 86% Min.Rated input voltage 100 to 240 VACAllowable-input voltage&n