Omron Power Supply S8EX Series S8EX-BP10048L

Omron Power Supply S8EX Series S8EX-BP10048L
share

With chassis , Input 100 to 240 VAC , 100W , Output 48V 2.1A
Power rating 100 W
Efficiency 84% Min. ï¼ˆAt 100 VAC input)86% Min. ï¼ˆAt 200 VAC input)
Rated input voltage 100 to 240 VAC
Allowable-input voltage variable range 85 to 264 VAC120 to 370 VDC
Note at DC input The range for compliance with EC Directives and safety standards (UL, EN, etc.) is 100 to 240 VAC (85 to 264 VAC).
Frequency 50/60 Hz (47 to 63 Hz )
Rated input current 1.3 A TYP. ï¼ˆAt 100 VAC input)0.65 A TYP. ï¼ˆAt 200 VAC input)
Power factor 0.9 Min. (At rated input, 100% load)
Harmonic Current EN61000-3-2
Leakage current 0.5 mA Max. (At 100 VAC input)1 mA Max. (At 200 VAC input)
Inrush current 14.1 A TYP. ï¼ˆAt 100 VAC input (For cold start at 25 CEL))28.3 A TYP. ï¼ˆAt 200 VAC input (For cold start at 25 CEL))
Rated output voltage 48 VDC
Output voltage variable range -10 to +10% (With V. ADJ)(If the output voltage adjuster (V. ADJ) is turned, the voltage will increase by more than the allowable voltage range. When adjusting the output voltage, confirm the actual output voltage from the Power Supply and be sure that load is not damaged.)
Ripple 960 mV Max.
Static input variation influence 0.5% Max. (At 85 to 264 VAC input, 100% load)
Static load variation influence 1.5% Max. (At rated input, 0 to 100% load)
Ambient temperature variation influence 0.05 %/CEL Max.
Rated output current 2.1 A , 4.2 A (Peak current)
Start up time 650 ms TYP. ï¼ˆ100 VAC input)
Hold time 24 ms TYP. ï¼ˆ100 VAC input)
Overload protection 100% to 110% of power boost for output currenttVoltage drop, Intermittent operation, Automatic reset
Overvoltage protection Operated at 130% Min. of the rated output voltage, Shut-offResetting: Reset the power by turning it back (OFF time: at least 3 min)
Power factor improvement function Yes
Parallel operation No (However, backup operation is possible; external diodes required.)
Series operation Yes (Up to 2 Power Supplies)
Applicable standard (UL) Standard No.: UL UR: UL60950-1 (Recognition)
Applicable standard (CSA) Standard No.: cUR: CSA C22.2 No.60950-1
Applicable standard (EN) Standard No.: EN50178, EN60950-1
Applicable standard (EC Directive (EMI)) Emission Enclosure: Conforms to EN55011 Group 1 Class BEmission AC mains: Conforms to EN55011 Group 1 Class B
Applicable standard(SEMI) F47-0706 (200 VAC input)
Ambient temperature Operating: -10 to 70 CELStorage: -25 to 75 CEL(with no icing or condensation)
Ambient humidity Operating: 25 to 85% RHStorage: 25 to 90% RH(With no icing or condensation)
Dielectric strength Between all inputs and all outputs: 3 kVAC for 1 min (Detection current: 20 mA)Between all inputs and PE terminals: 2 kVAC for 1 min (Detection current: 20 mA)Between all outputs and PE terminals: 1 kVAC for 1 min (Detection current: 20 mA)
Insulation resistance Between all outputs and all inputs/ PE terminals: 100 MOhm Min.
Vibration resistance 10 to 55 Hz, 19.6 m/s**2 (2 G) in each 3 directions for 1 hour
Shock resistance 196.1 m/s**2, in each 6 directions 3 times
Heat radiation Natural air-cooling
Construction With chassis
Weight 410 g Max.

Omron Power Supply S8VS Series S8VS-12024
Omron Power Supply S8VS Series S8VS-12024
Total Run Time Monitor , Input 100 to 240 VAC , 60 W , Output 24 V 2.5 APower rating 60 WEfficiency 83% TYP. ï¼ˆAt 100 VAC input)85% TYP. ï¼ˆAt 200 V
Omron Power Supply S8VM Series S8VM-10015C
Omron Power Supply S8VM Series S8VM-10015C
Standard Type , Covered Type , Bottom Mounting Type , Input 100 to 240 VAC , 100 W , Output 15 V 7 APower rating 100 WEfficiency 81% Min.Rated input voltage 100
Omron Power Supply S8VM Series S8VM-03015
Omron Power Supply S8VM Series S8VM-03015
Standard Type , Open-Frame Type , Bottom Mounting Type , Input 100 to 240 VAC , 30 W , Output 15 V 2 APower rating 30 WEfficiency 79% Min.Rated input voltage 10
Omron Power Supply S8EX Series S8EX-P15005
Omron Power Supply S8EX Series S8EX-P15005
Open type , Input 100 to 240 VAC , 150W , Output 5V 30APower rating 150 WEfficiency 84% Min. ï¼ˆAt 100 VAC input)87% Min. ï¼ˆAt 200 VAC input)Rated inpu
Omron Power Supply S8VS Series S8VS-09024-F
Omron Power Supply S8VS Series S8VS-09024-F
Maintenance Forecast Monitor Type , Input 100 to 240 VAC , 90 W , Output 24 V 3.75 APower rating 90 WEfficiency 83% TYP. ï¼ˆAt 100 VAC input)85% TYP. ï¼ˆAt&nbs
Omron Power Supply S8VS Series S8VS-12024BE
Omron Power Supply S8VS Series S8VS-12024BE
Standard Model , Input 100 to 240 VAC , 30 W , Output 12 V 2.5 APower rating 30 WEfficiency 81% TYP. ï¼ˆAt 100 VAC input)80% TYP. ï¼ˆAt 200 VAC input)Rate
Omron Power Supply S8VS Series S8VS-09024
Omron Power Supply S8VS Series S8VS-09024
Total Run Time Monitor , Input 100 to 240 VAC , 90 W , Output 24 V 3.75 A , With Undervoltage Alarm (Ttransistor (Sourcing))Power rating 90 WEfficiency 83% TYP. 
Omron S8JX Switch Mode Power S8JX-G03512CD
Omron S8JX Switch Mode Power S8JX-G03512CD
Covered type , Input 100 to 240 VAC , 35 W , Output 12 V 3 A , DIN Rail mounting typeAs of November 15, 2012Power rating 35 WEfficiency 73% Min.Rated input
Omron S8JX Switch Mode Power S8JX-G05024D
Omron S8JX Switch Mode Power S8JX-G05024D
Open-Frame Type , Input 100 to 240 VAC , 50W , Output 24V 2.1A , DIN Rail mounting typePower rating 50 WEfficiency 83% Min.Rated input voltage 100 to 240 VACAllowable-inp
Omron S8JX Switch Mode Power S8JX-G01548CD
Omron S8JX Switch Mode Power S8JX-G01548CD
Covered type , Input 100 to 240 VAC , 15 W , Output 48 V 0.35 A , DIN Rail mounting typeAs of November 15, 2012Power rating 15 WEfficiency 68% Min.Rated in