Standard Type , Open-Frame Type , DIN Rail Mounting Bracket Type , Input 100 to 240 VAC , 100 W , Output 15 V 7 A
Power rating 100 W
Efficiency 81% Min.
Rated input voltage 100 to 240 VAC
Allowable-input voltage variable range 85 to 264 VAC
Frequency 50/60 Hz (47 to 63 Hz Single-phase)
Rated input current 1.4 A Max. ï¼ˆAt 100 VAC input)0.7 A Max. ï¼ˆAt 200 VAC input)
Power factor 0.98 Min. (At 100 VAC input)0.94 Min. (At 200 VAC input)
Harmonic Current EN61000-3-2
Leakage current 0.4 mA Max. (At 100 VAC input)0.75 mA Max. (At 200 VAC input)
Inrush current 17.5 A Max. ï¼ˆAt 100 VAC input (For cold start at 25 CEL))35 A Max. ï¼ˆAt 200 VAC input (For cold start at 25 CEL))
Rated output voltage 15 VDC
Output voltage variable range -20 to +20% (With V. ADJ)(The output voltage may increase beyond the allowable voltage range (up to +20% of the rated voltage) depending on the operation of the output voltage adjuster (V.ADJ). When adjusting the output voltage, check the output voltage of the Power Supply and be sure that the load is not damaged.)
Ripple 1.2%(p-p) Max.
Static input variation influence 0.4% Max. (At 85 to 264 VAC input, 100% load)
Static load variation influence 0.8% Max. (At rated input, 0 to 100% load)
Ambient temperature variation influence 0.02 %/CEL Max. (At rated input/output voltage)
Rated output current 7 A
Start up time 800 ms Max. ï¼ˆAt rated input/output voltage)
Hold time 20 ms TYP.
Overload protection 105% to 160% of the rated output currentInverted L voltage drop, Automatic reset
Overvoltage protection Operated at 140% Min. of the rated output voltage, Shut-offResetting: Reset the power by turning it back (OFF time: at least 3 min)
Maintenance forecast monitor output No
Total run time monitor output No
Undervoltage alarm output No
Power failure alarm indication No
Power failure alarm output No
Parallel operation No (However, backup operation is possible; external diodes required.)
Series operation Yes (Up to 2 Power Supplies with external diode)
Remote sensing function Yes
Applicable standard (UL) Standard No.: UL508 (Listing), UL60950-1, UL1604 (Listing, Class I / Division 2)
Applicable standard (CSA) Standard No.: cUL: CSA C22.2 No.14, No.213 (Class I / Division 2), cUR: CSA C22.2 No.60950-1
Applicable standard (EN) Standard No.: EN50178, EN60950-1
Applicable standard (EC Directive (EMI)) Emission Enclosure: Conforms to EN61204-3 Class BEmission AC mains: Conforms to EN61204-3 Class B and based on FCC Class B
Applicable standard(SEMI) F47-0200 (200 VAC input)
Ambient temperature Operating: -10 to 70 CELStorage: -25 to 65 CEL(with no icing or condensation)
Ambient humidity Operating: 30 to 85% RHStorage: 25 to 90% RH(With no icing or condensation)
Dielectric strength Between all inputs and all outputs: 3 kVAC for 1 min (Detection current: 20 mA)Between all inputs and PE/FG terminals: 2 kVAC for 1 min (Detection current: 20 mA)Between all outputs and PE/FG terminals: 500 VAC for 1 min (Detection current: 100 mA)
Insulation resistance Between all outputs and all inputs/ PE/FG terminals: 100 MOhm Min. (at 500 VDC)
Vibration resistance 10 to 55 Hz, 0.375 mm single amplitude in each 3 directions for 2 hours
Shock resistance 150 m/s**2, in each 6 directions 3 times
Output indicator Yes (color: green)
Heat radiation Natural air-cooling
Construction Open-frame type
Mounting type DIN Rail mounting type
Attachment Instruction manual

Omron Power Supply S8TX Series S8TS-06024
Omron Power Supply S8TX Series S8TS-06024
Basic Block , Screw Terminal , Input 100 to 240 VAC , Output 24 V 2.5 APower rating 60 WEfficiency 80% TYP. ï¼ˆAt rated input, 100% load)Rated input voltage 100 t
Omron S8JX Switch Mode Power S8JX-G03515D
Omron S8JX Switch Mode Power S8JX-G03515D
Open-Frame Type , Input 100 to 240 VAC , 35W , Output 15V 2.4A , DIN Rail mounting typeAs of November 15, 2012Power rating 35 WEfficiency 73% Min.Rated input voltage
Omron S8JX Switch Mode Power S8JX-P05012D
Omron S8JX Switch Mode Power S8JX-P05012D
Open-Frame Type , Input 100 to 240 VAC , 50W , Output 12V 4.2A , DIN Rail mounting typePower rating 50 WEfficiency 76% Min.Rated input voltage 100 to 240 VACAllowable-inp
Omron Power Supply S8EX Series S8EX-BP15024
Omron Power Supply S8EX Series S8EX-BP15024
Open type , Input 100 to 240 VAC , 150W , Output 24V 6.3APower rating 150 WEfficiency 84% Min. ï¼ˆAt 100 VAC input)87% Min. ï¼ˆAt 200 VAC input)Rated in
Omron Power Supply S8EX Series S8EX-N01515
Omron Power Supply S8EX Series S8EX-N01515
Open type , Input 100 to 240 VAC , 15W , Output 15V 1APower rating 15 WEfficiency 80% Min. ï¼ˆAt 100 VAC input)78% Min. ï¼ˆAt 200 VAC input)Rated input&
Omron Power Supply S8VS Series S8VS-18024BE
Omron Power Supply S8VS Series S8VS-18024BE
Total Run Time Monitor , Input 100 to 240 VAC , 180 W , Output 24 V 7.5 APower rating 180 WEfficiency 85% TYP. ï¼ˆAt 100 VAC input)87% TYP. ï¼ˆAt 200 
Omron Power Supply S8VM Series S8VM-10024
Omron Power Supply S8VM Series S8VM-10024
Standard Type , Open-Frame Type , Bottom Mounting Type , Input 100 to 240 VAC , 100 W , Output 24 V 4.5 APower rating 100 WEfficiency 82% Min.Rated input voltag
Omron Power Supply S8VS Series S8VS-24024BP-F
Omron Power Supply S8VS Series S8VS-24024BP-F
Total Run Time Monitor , Input 100 to 240 VAC , 240 W , Output 24 V 10 A , With Undervoltage Alarm (Ttransistor (Sourcing))Power rating 240 WEfficiency 85% TYP. 
Omron Power Supply S8VM Series S8VM-10015CD
Omron Power Supply S8VM Series S8VM-10015CD
Standard Type , Covered Type , DIN Rail Mounting Bracket Type , Input 100 to 240 VAC , 100 W , Output 15 V 7 APower rating 100 WEfficiency 81% Min.Rated in
Omron Power Supply S8VS Series S8VS-06024A-F
Omron Power Supply S8VS Series S8VS-06024A-F
Maintenance Forecast Monitor Type , Input 100 to 240 VAC , 120 W , Output 24 V 5 APower rating 120 WEfficiency 83% TYP. ï¼ˆAt 100 VAC input)85% TYP. ï¼ˆAt