Covered type , Input 100 to 240 VAC , 15 W , Output 48 V 0.35 A , DIN Rail mounting type
As of November 15, 2012
Power rating 15 W
Efficiency 68% Min.
Rated input voltage 100 to 240 VAC
Allowable-input voltage variable range 85 to 264 VAC80 to 370 VDC
Note at DC input The range for compliance with EC Directives and safety standards (UL, EN, etc.) is 100 to 240 VAC (85 to 264 VAC).
Frequency 50/60 Hz (47 to 450 Hz Single-phase)
Rated input current 0.4 A Max. Ã¯Â¼Ë†At 100 VAC input)0.25 A Max. Ã¯Â¼Ë†At 200 VAC input)
Leakage current 0.5 mA Max. (At 100 VAC input)1 mA Max. (At 200 VAC input)
Inrush current 20 A Max. Ã¯Â¼Ë†At 100 VAC input (For cold start at 25 CEL))40 A Max. Ã¯Â¼Ë†At 200 VAC input (For cold start at 25 CEL))
Rated output voltage 48 VDC
Output voltage variable range -10 to +10% (With V. ADJ)(If the output voltage adjuster (V. ADJ) is turned, the voltage will increase by more than the allowable voltage range. When adjusting the output voltage, confirm the actual output voltage from the Power Supply and be sure that load is not damaged.)
Ripple 2%(p-p) Max. (Under the rated I/O conditions.)
Static input variation influence 0.4% Max. (with AC input voltage)
Static load variation influence 0.8% Max. (At rated input, 0 to 100% load)
Ambient temperature variation influence 0.05 %/CEL Max. (At rated input/output voltage)
Rated output current 0.35 A
Start up time 500 ms Max. Ã¯Â¼Ë†Up to 90% of output voltage at rated input and output)
Hold time 20 ms Min. (At rated input voltage: 100 or 200 VAC at 100% load.)
Overload protection 105% to 175% of the rated output currentVoltage drop, Intermittent operation, Automatic reset
Overvoltage protection Operated at 120 to 140 % of the rated output voltage, Shut-offResetting: Reset the power by turning it back (OFF time: at least 7 min)
Overheat protection No
Maintenance forecast monitor output No
Total run time monitor output No
Undervoltage alarm output No
Power failure alarm output No
Parallel operation No (However, backup operation is possible; external diodes required.)
Series operation Yes (Up to 2 Power Supplies with external diode)
Remote sensing function No
Applicable standard (UL) Standard No.: UL Listed: UL508 (Listing), UL UR: UL60950-1 (Recognition)
Applicable standard (CSA) Standard No.: cUL Listed: CSA C22.2 No.107.1, cUR: CSA C22.2 No.60950-1
Applicable standard (EN) Standard No.: EN50178, EN60950-1
Applicable standard (EC Directive (EMI)) Emission Enclosure: Conforms to EN55011 Group 1 Class AEmission AC mains: Conforms to EN55011 Group 1 Class A and based on FCC Class AEMS: EN61204-3 High severity levels
Applicable standard(VDE) Standard No.: VDE0160, VDE0805 Teil 1 File number:
Applicable standard(SEMI) F47-0200 (200 VAC input)
Applicable standard(Other) Conformed standard 2: Terminal block: Based on DIN EN50274 (VDE0660-514)
Ambient temperature Operating: -10 to 60 CELStorage: -25 to 65 CEL(with no icing or condensation)
Ambient humidity Operating: 25 to 85%Storage: 25 to 90%(With no icing or condensation)
Dielectric strength Between all inputs and all outputs: 3 kVAC for 1 min (Detection current: 20 mA)Between all inputs and PE terminals: 2 kVAC for 1 min (Detection current: 20 mA)Between all outputs and PE terminals: 1 kVAC for 1 min (Detection current: 20 mA)
Insulation resistance Between all outputs and all inputs/ PE terminals: 100 MOhm Min. (at 500 VDC)
Vibration resistance 10 to 55 Hz, 0.375 mm single amplitude in each 3 directions for 2 hours
Shock resistance 150 m/s**2, in each 6 directions 3 times
Output indicator Yes (color: green)
Heat radiation Natural air-cooling
Construction Covered type
Terminal type Screw terminal
Mounting type DIN Rail mounting type
Weight 370 g Max.

Omron Power Supply S8VS Series S8VS-03024
Omron Power Supply S8VS Series S8VS-03024
Total Run Time Monitor , Input 100 to 240 VAC , 120 W , Output 24 V 5 APower rating 120 WEfficiency 83% TYP. Ã¯Â¼Ë†At 100 VAC input)85% TYP. Ã¯Â¼Ë†At 200 V
Omron Power Supply S8JX Switch Mode Power S8JX-G15012
Omron Power Supply S8JX Switch Mode Power S8JX-G15012
Open-Frame Type , Input 100 to 240 VAC , 150W , Output 12V 13A , Front-mounting typePower rating 150 WEfficiency 79% Min.Rated input voltage 100 to 240 VACAllowable-input volt
Omron Power Supply S8EX Series S8EX-BP10048
Omron Power Supply S8EX Series S8EX-BP10048
Open type , Input 100 to 240 VAC , 100W , Output 48V 2.1APower rating 100 WEfficiency 84% Min. Ã¯Â¼Ë†At 100 VAC input)86% Min. Ã¯Â¼Ë†At 200 VAC input)Rated in
Omron Power Supply S8VS Series S8VS-03005
Omron Power Supply S8VS Series S8VS-03005
Total Run Time Monitor , Input 100 to 240 VAC , 120 W , Output 24 V 5 APower rating 120 WEfficiency 83% TYP. Ã¯Â¼Ë†At 100 VAC input)85% TYP. Ã¯Â¼Ë†At 200 V
Omron Power Supply S8EX Series S8EX-N03015L
Omron Power Supply S8EX Series S8EX-N03015L
With chassis and cover , Input 100 to 240 VAC , 30W , Output 15V 2APower rating 30 WEfficiency 83% Min. Ã¯Â¼Ë†At 100 VAC input)83% Min. Ã¯Â¼Ë†At 200 VAC inputÃ
Omron Power Supply S8JX Switch Mode Power S8JX-G10012CD
Omron Power Supply S8JX Switch Mode Power S8JX-G10012CD
Covered type , Input 100 to 240 VAC , 100 W , Output 12 V 8.5 A , DIN Rail mounting typePower rating 100 WEfficiency 81% Min.Rated input voltage 100 to 240 
Omron Power Supply S8JX Switch Mode Power S8JX-G15005
Omron Power Supply S8JX Switch Mode Power S8JX-G15005
Open-Frame Type , Input Switchable between 100 to 120 VAC and 200 to 240 VAC , 150W , Output 5V 30A , Front-mounting typePower rating 150 WEfficiency 78% Min.Rated i
Omron S8JX Switch Mode Power S8JX-G05012
Omron S8JX Switch Mode Power S8JX-G05012
Open-Frame Type , Input 100 to 240 VAC , 50W , Output 12V 4.2A , Front-mounting typePower rating 50 WEfficiency 81% Min.Rated input voltage 100 to 240 VACAllowable-input volta
Omron Power Supply S8VS Series S8VS-06024B
Omron Power Supply S8VS Series S8VS-06024B
Maintenance Forecast Monitor Type , Input 100 to 240 VAC , 120 W , Output 24 V 5 APower rating 120 WEfficiency 83% TYP. Ã¯Â¼Ë†At 100 VAC input)85% TYP. Ã¯Â¼Ë†At 
Omron Power Supply S8TX Series S8TS-02505
Omron Power Supply S8TX Series S8TS-02505
Basic Block , Screw Terminal , Input 100 to 240 VAC , Output 5 V 5 APower rating 25 WEfficiency 73% TYP. Ã¯Â¼Ë†At rated input, 100% load)Rated input voltage 100 to&n