Omron Power Supply S8VM Series S8VM-01512C-Power Supply, Battery and Inverter
 
Cart()
 
 
Categories
Contact Us
  • A&S Power Supply Co.,Ltd
  • Address:469, Xinsheng Road, Gaoxin District, Chengdu, Sichuan, China
  • Tel:+86-28-65376776
  • Fax:+86-28-86129221
  • Email:inverter@electrical8.com
  • Contact Person:Karina
Home / Products / power supply / Omron Power Supply / S8VM / Omron Power Supply S8VM Series S8VM-01512C

Omron Power Supply S8VM Series S8VM-01512C

Omron Power Supply S8VM Series S8VM-01512C
share

Standard Type , Covered Type , Bottom Mounting Type , Input 100 to 240 VAC , 15 W , Output 12 V 1.3 A
Power rating 15 W
Efficiency 78% Min.
Rated input voltage 100 to 240 VAC
Allowable-input voltage variable range 85 to 264 VAC
Frequency 50/60 Hz (47 to 63 Hz Single-phase)
Rated input current 0.5 A Max. Ã¯Â¼Ë†At 100 VAC input)0.25 A Max. Ã¯Â¼Ë†At 200 VAC input)
Leakage current 0.4 mA Max. (At 100 VAC input)0.75 mA Max. (At 200 VAC input)
Inrush current 17.5 A Max. Ã¯Â¼Ë†At 100 VAC input (For cold start at 25 CEL))35 A Max. Ã¯Â¼Ë†At 200 VAC input (For cold start at 25 CEL))
Rated output voltage 12 VDC
Output voltage variable range -20 to +20% (With V. ADJ)(The output voltage may increase beyond the allowable voltage range (up to +20% of the rated voltage) depending on the operation of the output voltage adjuster (V.ADJ). When adjusting the output voltage, check the output voltage of the Power Supply and be sure that the load is not damaged.)
Ripple 1.5%(p-p) Max.
Static input variation influence 0.4% Max. (At 85 to 264 VAC input, 100% load)
Static load variation influence 0.8% Max. (At rated input, 0 to 100% load)
Ambient temperature variation influence 0.02 %/CEL Max. (At rated input/output voltage)
Rated output current 1.3 A
Start up time 1100 ms Max. Ã¯Â¼Ë†At rated input/output voltage)
Hold time 20 ms TYP.
Overload protection 105% to 160% of the rated output currentGradual current increase/voltage drop, Intermittent operation, Automatic reset
Overvoltage protection Operated at 125 to 145 % of the rated output voltage, Shut-offResetting: Reset the power by turning it back (OFF time: at least 3 min)
Maintenance forecast monitor output No
Total run time monitor output No
Undervoltage alarm output No
Power failure alarm indication No
Power failure alarm output No
Parallel operation No (However, backup operation is possible; external diodes required.)
Series operation Yes (Up to 2 Power Supplies with external diode)
Remote sensing function No
Applicable standard (UL) Standard No.: UL508 (Listing), UL60950-1, UL1604 (Listing, Class I / Division 2)
Applicable standard (CSA) Standard No.: cUL: CSA C22.2 No.14, No.213 (Class I / Division 2), cUR: CSA C22.2 No.60950-1
Applicable standard (EN) Standard No.: EN50178, EN60950-1
Applicable standard (EC Directive (EMI)) Emission Enclosure: Conforms to EN61204-3 Class BEmission AC mains: Conforms to EN61204-3 Class B and based on FCC Class B
Applicable standard(SEMI) F47-0200 (200 VAC input)
Applicable standard(Other) Conformed standard 2: VDE0106 / P100
Ambient temperature Operating: -10 to 60 CELStorage: -25 to 65 CEL(with no icing or condensation)
Ambient humidity Operating: 30 to 85% RHStorage: 25 to 90% RH(With no icing or condensation)
Dielectric strength Between all inputs and all outputs: 3 kVAC for 1 min (Detection current: 20 mA)Between all inputs and PE/FG terminals: 2 kVAC for 1 min (Detection current: 20 mA)Between all outputs and PE/FG terminals: 500 VAC for 1 min (Detection current: 100 mA)
Insulation resistance Between all outputs and all inputs/ PE/FG terminals: 100 MOhm Min. (at 500 VDC)
Vibration resistance 10 to 55 Hz, 0.375 mm single amplitude in each 3 directions for 2 hours
Shock resistance 150 m/s**2, in each 6 directions 3 times
Output indicator Yes (color: green)
Heat radiation Natural air-cooling
Construction Covered type
Mounting type Bottom-mounting type
Attachment Instruction manual

Omron Power Supply S8VM Series S8VM-01505CD
Omron Power Supply S8VM Series S8VM-01505CD
Standard Type , Covered Type , DIN Rail Mounting Bracket Type , Input 100 to 240 VAC , 15 W , Output 5 V 3 APower rating 15 WEfficiency 75% Min.Rated input
Omron Power Supply S8EX Series S8EX-N01515LC
Omron Power Supply S8EX Series S8EX-N01515LC
With chassis and cover , Input 100 to 240 VAC , 15W , Output 15V 1APower rating 15 WEfficiency 80% Min. Ã¯Â¼Ë†At 100 VAC input)78% Min. Ã¯Â¼Ë†At 200 VAC inputÃ
Omron Power Supply S8JX Switch Mode Power S8JX-P30048CD
Omron Power Supply S8JX Switch Mode Power S8JX-P30048CD
Covered type , Input 100 to 240 VAC , 300W , Output 48V 7A , DIN Rail mounting typePower rating 300 WEfficiency 78% Min.Rated input voltage 100 to 240 VACAllowable-input&
Omron Power Supply S8VM Series S8VM-03024D
Omron Power Supply S8VM Series S8VM-03024D
Standard Type , Open-Frame Type , DIN Rail Mounting Bracket Type , Input 100 to 240 VAC , 30 W , Output 24 V 1.3 APower rating 30 WEfficiency 81% Min.Rated 
Omron Power Supply S8VM Series S8VM-03012CD
Omron Power Supply S8VM Series S8VM-03012CD
Standard Type , Covered Type , DIN Rail Mounting Bracket Type , Input 100 to 240 VAC , 30 W , Output 12 V 2.5 APower rating 30 WEfficiency 79% Min.Rated in
Omron Power Supply S8VM Series S8VM-05012D
Omron Power Supply S8VM Series S8VM-05012D
Standard Type , Open-Frame Type , DIN Rail Mounting Bracket Type , Input 100 to 240 VAC , 50 W , Output 12 V 4.3 APower rating 50 WEfficiency 79% Min.Rated 
Omron Power Supply S8VS Series S8VS-12024AP
Omron Power Supply S8VS Series S8VS-12024AP
Maintenance Forecast Monitor Type , Input 100 to 240 VAC , 60 W , Output 24 V 2.5 APower rating 60 WEfficiency 83% TYP. Ã¯Â¼Ë†At 100 VAC input)85% TYP. Ã¯Â¼Ë†At 
Omron Power Supply S8TX Series S8TS-02505F
Omron Power Supply S8TX Series S8TS-02505F
Basic Block , Connector Terminal Type , Input 100 to 240 VAC , Output 5 V 5 APower rating 25 WEfficiency 73% TYP. Ã¯Â¼Ë†At rated input, 100% load)Rated input voltage
Omron Power Supply S8JX Switch Mode Power S8JX-P10024C
Omron Power Supply S8JX Switch Mode Power S8JX-P10024C
Covered type , Input 100 to 240 VAC , 100W , Output 24V 4.5A , Front-mounting typePower rating 100 WEfficiency 81% Min.Rated input voltage 100 to 240 VACAllowable-input voltag
Omron Power Supply S8VS Series S8VS-18024BP-F
Omron Power Supply S8VS Series S8VS-18024BP-F
Total Run Time Monitor , Input 100 to 240 VAC , 180 W , Output 24 V 7.5 A , With Undervoltage Alarm (Ttransistor (Sourcing))Power rating 180 WEfficiency 85% TYP.&nbs