Omron Power Supply S8VM Series S8VM-05012D

Omron Power Supply S8VM Series S8VM-05012D
share

Standard Type , Open-Frame Type , DIN Rail Mounting Bracket Type , Input 100 to 240 VAC , 50 W , Output 12 V 4.3 A
Power rating 50 W
Efficiency 79% Min.
Rated input voltage 100 to 240 VAC
Allowable-input voltage variable range 85 to 264 VAC
Frequency 50/60 Hz (47 to 63 Hz Single-phase)
Rated input current 0.8 A Max. ï¼ˆAt 100 VAC input)0.4 A Max. ï¼ˆAt 200 VAC input)
Power factor 0.98 Min. (At 100 VAC input)0.94 Min. (At 200 VAC input)
Harmonic Current EN61000-3-2
Leakage current 0.4 mA Max. (At 100 VAC input)0.75 mA Max. (At 200 VAC input)
Inrush current 17.5 A Max. ï¼ˆAt 100 VAC input (For cold start at 25 CEL))35 A Max. ï¼ˆAt 200 VAC input (For cold start at 25 CEL))
Rated output voltage 12 VDC
Output voltage variable range -20 to +20% (With V. ADJ)(The output voltage may increase beyond the allowable voltage range (up to +20% of the rated voltage) depending on the operation of the output voltage adjuster (V.ADJ). When adjusting the output voltage, check the output voltage of the Power Supply and be sure that the load is not damaged.)
Ripple 1.5%(p-p) Max.
Static input variation influence 0.4% Max. (At 85 to 264 VAC input, 100% load)
Static load variation influence 0.8% Max. (At rated input, 0 to 100% load)
Ambient temperature variation influence 0.02 %/CEL Max. (At rated input/output voltage)
Rated output current 4.3 A
Start up time 800 ms Max. ï¼ˆAt rated input/output voltage)
Hold time 20 ms TYP.
Overload protection 105% to 160% of the rated output currentInverted L voltage drop, Automatic reset
Overvoltage protection Operated at 125 to 145 % of the rated output voltage, Shut-offResetting: Reset the power by turning it back (OFF time: at least 3 min)
Maintenance forecast monitor output No
Total run time monitor output No
Undervoltage alarm output No
Power failure alarm indication No
Power failure alarm output No
Parallel operation No (However, backup operation is possible; external diodes required.)
Series operation Yes (Up to 2 Power Supplies with external diode)
Remote sensing function No
Applicable standard (UL) Standard No.: UL508 (Listing), UL60950-1, UL1604 (Listing, Class I / Division 2)
Applicable standard (CSA) Standard No.: cUL: CSA C22.2 No.14, No.213 (Class I / Division 2), cUR: CSA C22.2 No.60950-1
Applicable standard (EN) Standard No.: EN50178, EN60950-1
Applicable standard (EC Directive (EMI)) Emission Enclosure: Conforms to EN61204-3 Class BEmission AC mains: Conforms to EN61204-3 Class B and based on FCC Class B
Applicable standard(SEMI) F47-0200 (200 VAC input)
Applicable standard(Other) Conformed standard 2: VDE0106 / P100
Ambient temperature Operating: -10 to 70 CELStorage: -25 to 65 CEL(with no icing or condensation)
Ambient humidity Operating: 30 to 85% RHStorage: 25 to 90% RH(With no icing or condensation)
Dielectric strength Between all inputs and all outputs: 3 kVAC for 1 min (Detection current: 20 mA)Between all inputs and PE/FG terminals: 2 kVAC for 1 min (Detection current: 20 mA)Between all outputs and PE/FG terminals: 500 VAC for 1 min (Detection current: 100 mA)
Insulation resistance Between all outputs and all inputs/ PE/FG terminals: 100 MOhm Min. (at 500 VDC)
Vibration resistance 10 to 55 Hz, 0.375 mm single amplitude in each 3 directions for 2 hours
Shock resistance 150 m/s**2, in each 6 directions 3 times
Output indicator Yes (color: green)
Heat radiation Natural air-cooling
Construction Open-frame type
Mounting type DIN Rail mounting type
Attachment Instruction manual

Omron Power Supply S82S S82S-7305
Omron Power Supply S82S S82S-7305
Input 12 to 24 VDC , 3 W , Output 5 V 0.6 APower rating 3 WEfficiency 60% Min.Rated input voltage 12 to 24 VDCAllowable-input voltage variable range 10.2 to 27.6 VDC
Omron S8JX Switch Mode Power S8JX-G01548D
Omron S8JX Switch Mode Power S8JX-G01548D
Open-Frame Type , Input 100 to 240 VAC , 15W , Output 48V 0.35A , DIN Rail mounting typeAs of November 15, 2012Power rating 15 WEfficiency 68% Min.Rated input voltag
Omron Power Supply S8EX Series S8EX-BP15024L
Omron Power Supply S8EX Series S8EX-BP15024L
With chassis , Input 100 to 240 VAC , 150W , Output 24V 6.3APower rating 150 WEfficiency 84% Min. ï¼ˆAt 100 VAC input)87% Min. ï¼ˆAt 200 VAC input)Rated 
Omron S8JX Switch Mode Power S8JX-G03515
Omron S8JX Switch Mode Power S8JX-G03515
Open-Frame Type , Input 100 to 240 VAC , 35W , Output 15V 2.4A , Front-mounting typeAs of November 15, 2012Power rating 35 WEfficiency 73% Min.Rated input voltage 100 to&
Omron Power Supply S8VS Series S8VS-09024BES
Omron Power Supply S8VS Series S8VS-09024BES
Total Run Time Monitor , Input 100 to 240 VAC , 90 W , Output 24 V 3.75 APower rating 90 WEfficiency 83% TYP. ï¼ˆAt 100 VAC input)85% TYP. ï¼ˆAt 200 
Omron Power Supply S8VM Series S8VM-05024A
Omron Power Supply S8VM Series S8VM-05024A
Undervoltage Alarm Type , Covered Type , Bottom Mounting Type , Input 100 to 240 VAC , 50 W , Output 24 V 2.2 APower rating 50 WEfficiency 80% Min.Rated input&n
Omron Power Supply S8JX Switch Mode Power S8JX-P30048CD
Omron Power Supply S8JX Switch Mode Power S8JX-P30048CD
Covered type , Input 100 to 240 VAC , 300W , Output 48V 7A , DIN Rail mounting typePower rating 300 WEfficiency 78% Min.Rated input voltage 100 to 240 VACAllowable-input&
Omron Power Supply S8JX Switch Mode Power S8JX-P15012
Omron Power Supply S8JX Switch Mode Power S8JX-P15012
Open-Frame Type , Input 100 to 240 VAC , 150W , Output 12V 13A , Front-mounting typePower rating 150 WEfficiency 78% Min.Rated input voltage 100 to 240 VACAllowable-input volt
Omron Power Supply S8EX Series S8EX-N01548L
Omron Power Supply S8EX Series S8EX-N01548L
With chassis , Input 100 to 240 VAC , 15W , Output 48V 0.32APower rating 15 WEfficiency 83% Min. ï¼ˆAt 100 VAC input)82% Min. ï¼ˆAt 200 VAC input)Rated 
Omron S8JX Switch Mode Power S8JX-G03512
Omron S8JX Switch Mode Power S8JX-G03512
Open-Frame Type , Input 100 to 240 VAC , 35W , Output 12V 3A , Front-mounting typeAs of November 15, 2012Power rating 35 WEfficiency 73% Min.Rated input voltage 100 to&nb