- power supply
- TDK Lambda Power Supply
- Yamaha Power Supply
- Omron Power Supply
- Plus Power Supply
- Bestec Power Supply
- Sorensen Power Supply
- Antec Power Supply
- Meanwell Power Supply
- Weidmuller Power Supply
- Hipro Power Supply
- Sparkle Power Supply
- Lenovo Power Supply
- Zippy Power Supply
- Enermax Power Supply
- Agilent Power Supply
- Phihong Power Supply
- Liteon power supply
- Acble Power Supply
- Instek Power Supply
- Zalman Power Supply
- FSP Power Supply
- Aopen Power Supply
- Spellman Supply
- Delta Supply
- Cosel Supply
- Aj`s Power Source Supply
- Coolmax Supply
- MEAN WELL Power Supply
- SENDON Power Supply
- MGE Power Supply
- UPS Power Supply
- APC UPS Power Supply
- Riello UPS Power Supply
- EATON UPS Power Supply
- SANTAK UPS Power Supply
- Siemens UPS Power Supply
- Powerware UPS Power Supply
- OMRON UPS Power Supply
- Mitsubishi UPS Power Suppply
- DELTA Uninterruptible Power Supply
- EAST UPS Power Supply
- EMERSON UPS Power Supply
- Fuji UPS Power Supply
- EFFEKTA Uninterruptible Power Supply
- Gutor UPS Power Supply
- KELONG UPS Power Supply
- LADIS Uninterruptible Power Supply
- CBC UPS Power Supply
- Phoenix UPS Power Supply
- SVC Uninterruptible Power Supply
- Avaya UPS Power Supply
- NETCCA Uninterruptible Power Supply
- battery
- inverter
- Xantrex inverter
- Samlex inverter
- Schumacher inverter
- KACO inverter
- Wagan inverter
- AIMS inverter
- Victron inverter
- Targus inverter
- Whistler inverter
- Enphase inverter
- Satcon inverter
- Sima inverter
- Kensington inverter
- Exeltech inverter
- Stanley inverter
- ABB inverter
- SMA inverter
- Hyundai inverter
- Mastervolt inverter
- YAMAHA inverter
- Belkin inverter
- Microtek inverter
- Growatt inverter
- TDK inverter
- TOSHIBA inverter
- Su kam inverter
- Omnik inverter
- Ingeteam inverter
- Samil Power inverter
- Sungrow inverter
- Cobra inverter
- Power Bright inverter
- Bestek inverter
- A&S Power Supply Co.,Ltd
- Address:469, Xinsheng Road, Gaoxin District, Chengdu, Sichuan, China
- Tel:+86-28-65376776
- Fax:+86-28-86129221
- Email:inverter@electrical8.com
- Contact Person:Karina
Omron Power Supply S8VM Series S8VM-03012
Standard Type , Open-Frame Type , Bottom Mounting Type , Input 100 to 240 VAC , 30 W , Output 12 V 2.5 A
Power rating 30 W
Efficiency 79% Min.
Rated input voltage 100 to 240 VAC
Allowable-input voltage variable range 85 to 264 VAC
Frequency 50/60 Hz (47 to 63 Hz Single-phase)
Rated input current 0.9 A Max. (At 100 VAC input)0.45 A Max. (At 200 VAC input)
Leakage current 0.4 mA Max. (At 100 VAC input)0.75 mA Max. (At 200 VAC input)
Inrush current 17.5 A Max. (At 100 VAC input (For cold start at 25 CEL))35 A Max. (At 200 VAC input (For cold start at 25 CEL))
Rated output voltage 12 VDC
Output voltage variable range -20 to +20% (With V. ADJ)(The output voltage may increase beyond the allowable voltage range (up to +20% of the rated voltage) depending on the operation of the output voltage adjuster (V.ADJ). When adjusting the output voltage, check the output voltage of the Power Supply and be sure that the load is not damaged.)
Ripple 1.5%(p-p) Max.
Static input variation influence 0.4% Max. (At 85 to 264 VAC input, 100% load)
Static load variation influence 0.8% Max. (At rated input, 0 to 100% load)
Ambient temperature variation influence 0.02 %/CEL Max. (At rated input/output voltage)
Rated output current 2.5 A
Start up time 1100 ms Max. (At rated input/output voltage)
Hold time 20 ms TYP.
Overload protection 105% to 160% of the rated output currentGradual current increase/voltage drop, Intermittent operation, Automatic reset
Overvoltage protection Operated at 125 to 145 % of the rated output voltage, Shut-offResetting: Reset the power by turning it back (OFF time: at least 3 min)
Maintenance forecast monitor output No
Total run time monitor output No
Undervoltage alarm output No
Power failure alarm indication No
Power failure alarm output No
Parallel operation No (However, backup operation is possible; external diodes required.)
Series operation Yes (Up to 2 Power Supplies with external diode)
Remote sensing function No
Applicable standard (UL) Standard No.: UL508 (Listing), UL60950-1, UL1604 (Listing, Class I / Division 2)
Applicable standard (CSA) Standard No.: cUL: CSA C22.2 No.14, No.213 (Class I / Division 2), cUR: CSA C22.2 No.60950-1
Applicable standard (EN) Standard No.: EN50178, EN60950-1
Applicable standard (EC Directive (EMI)) Emission Enclosure: Conforms to EN61204-3 Class BEmission AC mains: Conforms to EN61204-3 Class B and based on FCC Class B
Applicable standard(SEMI) F47-0200 (200 VAC input)
Applicable standard(Other) Conformed standard 2: VDE0106 / P100
Ambient temperature Operating: -10 to 70 CELStorage: -25 to 65 CEL(with no icing or condensation)
Ambient humidity Operating: 30 to 85% RHStorage: 25 to 90% RH(With no icing or condensation)
Dielectric strength Between all inputs and all outputs: 3 kVAC for 1 min (Detection current: 20 mA)Between all inputs and PE/FG terminals: 2 kVAC for 1 min (Detection current: 20 mA)Between all outputs and PE/FG terminals: 500 VAC for 1 min (Detection current: 100 mA)
Insulation resistance Between all outputs and all inputs/ PE/FG terminals: 100 MOhm Min. (at 500 VDC)
Vibration resistance 10 to 55 Hz, 0.375 mm single amplitude in each 3 directions for 2 hours
Shock resistance 150 m/s**2, in each 6 directions 3 times
Output indicator Yes (color: green)
Heat radiation Natural air-cooling
Construction Open-frame type
Mounting type Bottom-mounting type
Attachment Instruction manual
Weight 220 g Max.
Standard Model , Input 100 to 240 VAC , 60 W , Output 24 V 2.5 APower rating 60 WEfficiency 84% TYP. (At 100 VAC input)83% TYP. (At 200 VAC input)Rate
Standard Model , Input 100 to 240 VAC , 30 W , Output 12 V 2.5 APower rating 30 WEfficiency 81% TYP. (At 100 VAC input)80% TYP. (At 200 VAC input)Rate
Maintenance Forecast Monitor Type , Input 100 to 240 VAC , 60 W , Output 24 V 2.5 APower rating 60 WEfficiency 83% TYP. (At 100 VAC input)85% TYP. (At 
Total Run Time Monitor , Input 100 to 240 VAC , 180 W , Output 24 V 7.5 APower rating 180 WEfficiency 85% TYP. (At 100 VAC input)87% TYP. (At 200 
Maintenance Forecast Monitor Type , Input 100 to 240 VAC , 240 W , Output 24 V 10 APower rating 240 WEfficiency 85% TYP. (At 100 VAC input)88% TYP. (At&nbs
Standard Type , Open-Frame Type , DIN Rail Mounting Bracket Type , Input 100 to 240 VAC , 100 W , Output 24 V 4.5 APower rating 100 WEfficiency 82% Min.Rated&nb
Standard Type , Covered Type , Bottom Mounting Type , Input 100 to 240 VAC , 50 W , Output 5 V 10 APower rating 50 WEfficiency 80% Min.Rated input voltage 100&n
Maintenance Forecast Monitor Type , Input 100 to 240 VAC , 180 W , Output 24 V 7.5 A , With Undervoltage Alarm (Ttransistor (Sourcing))Power rating 180 WEfficiency 85%&nb
Standard Type , Open-Frame Type , Bottom Mounting Type , Input 100 to 240 VAC , 15 W , Output 24 V 0.65 APower rating 15 WEfficiency 80% Min.Rated input voltage
Covered type , Input 100 to 240 VAC , 300W , Output 24V 14A , Without mounting brackets typePower rating 300 WEfficiency 79% Min.Rated input voltage 100 to 240 VACAllowab