Omron Power Supply S8EX Series S8EX-BP10048

Omron Power Supply S8EX Series S8EX-BP10048
share

Open type , Input 100 to 240 VAC , 100W , Output 48V 2.1A
Power rating 100 W
Efficiency 84% Min. ï¼ˆAt 100 VAC input)86% Min. ï¼ˆAt 200 VAC input)
Rated input voltage 100 to 240 VAC
Allowable-input voltage variable range 85 to 264 VAC120 to 370 VDC
Note at DC input The range for compliance with EC Directives and safety standards (UL, EN, etc.) is 100 to 240 VAC (85 to 264 VAC).
Frequency 50/60 Hz (47 to 63 Hz )
Rated input current 1.3 A TYP. ï¼ˆAt 100 VAC input)0.65 A TYP. ï¼ˆAt 200 VAC input)
Power factor 0.9 Min. (At rated input, 100% load)
Harmonic Current EN61000-3-2
Leakage current 0.5 mA Max. (At 100 VAC input)1 mA Max. (At 200 VAC input)
Inrush current 14.1 A TYP. ï¼ˆAt 100 VAC input (For cold start at 25 CEL))28.3 A TYP. ï¼ˆAt 200 VAC input (For cold start at 25 CEL))
Rated output voltage 48 VDC
Output voltage variable range -10 to +10% (With V. ADJ)(If the output voltage adjuster (V. ADJ) is turned, the voltage will increase by more than the allowable voltage range. When adjusting the output voltage, confirm the actual output voltage from the Power Supply and be sure that load is not damaged.)
Ripple 960 mV Max.
Static input variation influence 0.5% Max. (At 85 to 264 VAC input, 100% load)
Static load variation influence 1.5% Max. (At rated input, 0 to 100% load)
Ambient temperature variation influence 0.05 %/CEL Max.
Rated output current 2.1 A , 4.2 A (Peak current)
Start up time 650 ms TYP. ï¼ˆ100 VAC input)
Hold time 24 ms TYP. ï¼ˆ100 VAC input)
Overload protection 100% to 110% of power boost for output currenttVoltage drop, Intermittent operation, Automatic reset
Overvoltage protection Operated at 130% Min. of the rated output voltage, Shut-offResetting: Reset the power by turning it back (OFF time: at least 3 min)
Power factor improvement function Yes
Parallel operation No (However, backup operation is possible; external diodes required.)
Series operation Yes (Up to 2 Power Supplies)
Applicable standard (UL) Standard No.: UL UR: UL60950-1 (Recognition)
Applicable standard (CSA) Standard No.: cUR: CSA C22.2 No.60950-1
Applicable standard (EN) Standard No.: EN50178, EN60950-1
Applicable standard (EC Directive (EMI)) Emission Enclosure: Conforms to EN55011 Group 1 Class BEmission AC mains: Conforms to EN55011 Group 1 Class B
Applicable standard(SEMI) F47-0706 (200 VAC input)
Ambient temperature Operating: -10 to 70 CELStorage: -25 to 75 CEL(with no icing or condensation)
Ambient humidity Operating: 25 to 85% RHStorage: 25 to 90% RH(With no icing or condensation)
Dielectric strength Between all inputs and all outputs: 3 kVAC for 1 min (Detection current: 20 mA)Between all inputs and PE terminals: 2 kVAC for 1 min (Detection current: 20 mA)Between all outputs and PE terminals: 1 kVAC for 1 min (Detection current: 20 mA)
Insulation resistance Between all outputs and all inputs/ PE terminals: 100 MOhm Min.
Vibration resistance 10 to 55 Hz, 19.6 m/s**2 (2 G) in each 3 directions for 1 hour
Shock resistance 196.1 m/s**2, in each 6 directions 3 times
Heat radiation Natural air-cooling
Construction Open-frame type
Weight 265 g Max.

Omron Power Supply S8VS Series S8VS-24024BP
Omron Power Supply S8VS Series S8VS-24024BP
Total Run Time Monitor , Input 100 to 240 VAC , 240 W , Output 24 V 10 A , With Undervoltage Alarm (Ttransistor (Sourcing))Power rating 240 WEfficiency 85% TYP. 
Omron Power Supply S8VM Series S8VM-05015D
Omron Power Supply S8VM Series S8VM-05015D
Standard Type , Open-Frame Type , DIN Rail Mounting Bracket Type , Input 100 to 240 VAC , 50 W , Output 15 V 3.5 APower rating 50 WEfficiency 79% Min.Rated 
Omron Power Supply S8VS Series S8VS-09024-F
Omron Power Supply S8VS Series S8VS-09024-F
Maintenance Forecast Monitor Type , Input 100 to 240 VAC , 90 W , Output 24 V 3.75 APower rating 90 WEfficiency 83% TYP. ï¼ˆAt 100 VAC input)85% TYP. ï¼ˆAt&nbs
Omron Power Supply S8JX Switch Mode Power S8JX-G10012
Omron Power Supply S8JX Switch Mode Power S8JX-G10012
Open-Frame Type , Input 100 to 240 VAC , 100W , Output 12V 8.5A , Front-mounting typePower rating 100 WEfficiency 81% Min.Rated input voltage 100 to 240 VACAllowable-input vol
Omron Power Supply S8EX Series S8EX-P10005
Omron Power Supply S8EX Series S8EX-P10005
Open type , Input 100 to 240 VAC , 100W , Output 5V 20APower rating 100 WEfficiency 81% Min. ï¼ˆAt 100 VAC input)84% Min. ï¼ˆAt 200 VAC input)Rated inpu
Omron Power Supply S8VM Series S8VM-10024AD
Omron Power Supply S8VM Series S8VM-10024AD
Undervoltage Alarm Type , Covered Type , DIN Rail Mounting Bracket Type , Input 100 to 240 VAC , 100 W , Output 24 V 4.5 APower rating 100 WEfficiency 82% 
Omron Power Supply S8JX Switch Mode Power S8JX-G10024
Omron Power Supply S8JX Switch Mode Power S8JX-G10024
Open-Frame Type , Input 100 to 240 VAC , 100W , Output 24V 4.5A , Front-mounting typePower rating 100 WEfficiency 83% Min.Rated input voltage 100 to 240 VACAllowable-input vol
Omron Power Supply S8VS Series S8VS-24024BP-F
Omron Power Supply S8VS Series S8VS-24024BP-F
Total Run Time Monitor , Input 100 to 240 VAC , 240 W , Output 24 V 10 A , With Undervoltage Alarm (Ttransistor (Sourcing))Power rating 240 WEfficiency 85% TYP. 
Omron S8JX Switch Mode Power S8JX-P05012D
Omron S8JX Switch Mode Power S8JX-P05012D
Open-Frame Type , Input 100 to 240 VAC , 50W , Output 12V 4.2A , DIN Rail mounting typePower rating 50 WEfficiency 76% Min.Rated input voltage 100 to 240 VACAllowable-inp
Omron Power Supply S8EX Series S8EX-N01548LC
Omron Power Supply S8EX Series S8EX-N01548LC
With chassis and cover , Input 100 to 240 VAC , 15W , Output 48V 0.32APower rating 15 WEfficiency 83% Min. ï¼ˆAt 100 VAC input)82% Min. ï¼ˆAt 200 VAC inp