Cart()
 
 
Categories
Contact Us
  • A&S Power Supply Co.,Ltd
  • Address:469, Xinsheng Road, Gaoxin District, Chengdu, Sichuan, China
  • Tel:+86-28-65376776
  • Fax:+86-28-86129221
  • Email:inverter@electrical8.com
  • Contact Person:Karina
Home / Products / power supply / Omron Power Supply / S8EX / Omron Power Supply S8EX Series S8EX-BP10048

Omron Power Supply S8EX Series S8EX-BP10048

Omron Power Supply S8EX Series S8EX-BP10048
share

Open type , Input 100 to 240 VAC , 100W , Output 48V 2.1A
Power rating 100 W
Efficiency 84% Min. ï¼ˆAt 100 VAC input)86% Min. ï¼ˆAt 200 VAC input)
Rated input voltage 100 to 240 VAC
Allowable-input voltage variable range 85 to 264 VAC120 to 370 VDC
Note at DC input The range for compliance with EC Directives and safety standards (UL, EN, etc.) is 100 to 240 VAC (85 to 264 VAC).
Frequency 50/60 Hz (47 to 63 Hz )
Rated input current 1.3 A TYP. ï¼ˆAt 100 VAC input)0.65 A TYP. ï¼ˆAt 200 VAC input)
Power factor 0.9 Min. (At rated input, 100% load)
Harmonic Current EN61000-3-2
Leakage current 0.5 mA Max. (At 100 VAC input)1 mA Max. (At 200 VAC input)
Inrush current 14.1 A TYP. ï¼ˆAt 100 VAC input (For cold start at 25 CEL))28.3 A TYP. ï¼ˆAt 200 VAC input (For cold start at 25 CEL))
Rated output voltage 48 VDC
Output voltage variable range -10 to +10% (With V. ADJ)(If the output voltage adjuster (V. ADJ) is turned, the voltage will increase by more than the allowable voltage range. When adjusting the output voltage, confirm the actual output voltage from the Power Supply and be sure that load is not damaged.)
Ripple 960 mV Max.
Static input variation influence 0.5% Max. (At 85 to 264 VAC input, 100% load)
Static load variation influence 1.5% Max. (At rated input, 0 to 100% load)
Ambient temperature variation influence 0.05 %/CEL Max.
Rated output current 2.1 A , 4.2 A (Peak current)
Start up time 650 ms TYP. ï¼ˆ100 VAC input)
Hold time 24 ms TYP. ï¼ˆ100 VAC input)
Overload protection 100% to 110% of power boost for output currenttVoltage drop, Intermittent operation, Automatic reset
Overvoltage protection Operated at 130% Min. of the rated output voltage, Shut-offResetting: Reset the power by turning it back (OFF time: at least 3 min)
Power factor improvement function Yes
Parallel operation No (However, backup operation is possible; external diodes required.)
Series operation Yes (Up to 2 Power Supplies)
Applicable standard (UL) Standard No.: UL UR: UL60950-1 (Recognition)
Applicable standard (CSA) Standard No.: cUR: CSA C22.2 No.60950-1
Applicable standard (EN) Standard No.: EN50178, EN60950-1
Applicable standard (EC Directive (EMI)) Emission Enclosure: Conforms to EN55011 Group 1 Class BEmission AC mains: Conforms to EN55011 Group 1 Class B
Applicable standard(SEMI) F47-0706 (200 VAC input)
Ambient temperature Operating: -10 to 70 CELStorage: -25 to 75 CEL(with no icing or condensation)
Ambient humidity Operating: 25 to 85% RHStorage: 25 to 90% RH(With no icing or condensation)
Dielectric strength Between all inputs and all outputs: 3 kVAC for 1 min (Detection current: 20 mA)Between all inputs and PE terminals: 2 kVAC for 1 min (Detection current: 20 mA)Between all outputs and PE terminals: 1 kVAC for 1 min (Detection current: 20 mA)
Insulation resistance Between all outputs and all inputs/ PE terminals: 100 MOhm Min.
Vibration resistance 10 to 55 Hz, 19.6 m/s**2 (2 G) in each 3 directions for 1 hour
Shock resistance 196.1 m/s**2, in each 6 directions 3 times
Heat radiation Natural air-cooling
Construction Open-frame type
Weight 265 g Max.

Omron Power Supply S8VM Series S8VM-01515
Omron Power Supply S8VM Series S8VM-01515
Standard Type , Open-Frame Type , Bottom Mounting Type , Input 100 to 240 VAC , 15 W , Output 15 V 1 APower rating 15 WEfficiency 78% Min.Rated input voltage 10
Omron Power Supply S8EX Series S8EX-N01524
Omron Power Supply S8EX Series S8EX-N01524
Open type , Input 100 to 240 VAC , 15W , Output 24V 0.7APower rating 15 WEfficiency 80% Min. ï¼ˆAt 100 VAC input)78% Min. ï¼ˆAt 200 VAC input)Rated inpu
Omron Power Supply S8VM Series S8VM-05024D
Omron Power Supply S8VM Series S8VM-05024D
Standard Type , Open-Frame Type , DIN Rail Mounting Bracket Type , Input 100 to 240 VAC , 50 W , Output 24 V 2.2 APower rating 50 WEfficiency 80% Min.Rated 
Omron Power Supply S8JX Switch Mode Power S8JX-G10012C
Omron Power Supply S8JX Switch Mode Power S8JX-G10012C
Covered type , Input 100 to 240 VAC , 100 W , Output 12 V 8.5 A , Front-mounting typePower rating 100 WEfficiency 81% Min.Rated input voltage 100 to 240 VACAllowable
Omron S8JX Switch Mode Power S8JX-G05012
Omron S8JX Switch Mode Power S8JX-G05012
Open-Frame Type , Input 100 to 240 VAC , 50W , Output 12V 4.2A , Front-mounting typePower rating 50 WEfficiency 81% Min.Rated input voltage 100 to 240 VACAllowable-input volta
Omron Power Supply S8JX Switch Mode Power S8JX-P15005D
Omron Power Supply S8JX Switch Mode Power S8JX-P15005D
Open-Frame Type , Input 100 to 240 VAC , 150W , Output 5V 30A , DIN Rail mounting typePower rating 150 WEfficiency 79% Min.Rated input voltage 100 to 240 VACAllowable-inp
Omron Power Supply S8JX Switch Mode Power S8JX-P15012D
Omron Power Supply S8JX Switch Mode Power S8JX-P15012D
Open-Frame Type , Input 100 to 240 VAC , 150W , Output 12V 13A , DIN Rail mounting typePower rating 150 WEfficiency 78% Min.Rated input voltage 100 to 240 VACAllowable-in
Omron Power Supply S8EX Series S8EX-N03005
Omron Power Supply S8EX Series S8EX-N03005
Open type , Input 100 to 240 VAC , 30W , Output 5V 6APower rating 30 WEfficiency 77% Min. ï¼ˆAt 100 VAC input)79% Min. ï¼ˆAt 200 VAC input)Rated input&n
Omron S8JX Switch Mode Power S8JX-G05048C
Omron S8JX Switch Mode Power S8JX-G05048C
Covered type , Input 100 to 240 VAC , 50 W , Output 48 V 1.1 A , Front-mounting typePower rating 50 WEfficiency 82% Min.Rated input voltage 100 to 240 VACAllowable-i
Omron Power Supply S8TX Series S8TS-03012F
Omron Power Supply S8TX Series S8TS-03012F
Basic Block , Connector Terminal Type , Input 100 to 240 VAC , Output 12 V 2.5 APower rating 30 WEfficiency 73% TYP. ï¼ˆAt rated input, 100% load)Rated input volt