With chassis and cover , Input 100 to 240 VAC , 100W , Output 24V 4.3A
Power rating 100 W
Efficiency 84% Min. ï¼ˆAt 100 VAC input)86% Min. ï¼ˆAt 200 VAC input)
Rated input voltage 100 to 240 VAC
Allowable-input voltage variable range 85 to 264 VAC120 to 370 VDC
Note at DC input The range for compliance with EC Directives and safety standards (UL, EN, etc.) is 100 to 240 VAC (85 to 264 VAC).
Frequency 50/60 Hz (47 to 63 Hz )
Rated input current 1.3 A TYP. ï¼ˆAt 100 VAC input)0.65 A TYP. ï¼ˆAt 200 VAC input)
Power factor 0.9 Min. (At rated input, 100% load)
Harmonic Current EN61000-3-2
Leakage current 0.5 mA Max. (At 100 VAC input)1 mA Max. (At 200 VAC input)
Inrush current 14.1 A TYP. ï¼ˆAt 100 VAC input (For cold start at 25 CEL))28.3 A TYP. ï¼ˆAt 200 VAC input (For cold start at 25 CEL))
Rated output voltage 24 VDC
Output voltage variable range -10 to +10% (With V. ADJ)(If the output voltage adjuster (V. ADJ) is turned, the voltage will increase by more than the allowable voltage range. When adjusting the output voltage, confirm the actual output voltage from the Power Supply and be sure that load is not damaged.)
Ripple 480 mV Max.
Static input variation influence 0.5% Max. (At 85 to 264 VAC input, 100% load)
Static load variation influence 1.5% Max. (At rated input, 0 to 100% load)
Ambient temperature variation influence 0.05 %/CEL Max.
Rated output current 4.3 A , 8.6 A (Peak current)
Start up time 540 ms TYP. ï¼ˆ100 VAC input)
Hold time 22 ms TYP. ï¼ˆ100 VAC input)
Overload protection 100% to 110% of power boost for output currenttVoltage drop, Intermittent operation, Automatic reset
Overvoltage protection Operated at 130% Min. of the rated output voltage, Shut-offResetting: Reset the power by turning it back (OFF time: at least 3 min)
Power factor improvement function Yes
Parallel operation No (However, backup operation is possible; external diodes required.)
Series operation Yes (Up to 2 Power Supplies)
Applicable standard (UL) Standard No.: UL UR: UL60950-1 (Recognition)
Applicable standard (CSA) Standard No.: cUR: CSA C22.2 No.60950-1
Applicable standard (EN) Standard No.: EN50178, EN60950-1
Applicable standard (EC Directive (EMI)) Emission Enclosure: Conforms to EN55011 Group 1 Class BEmission AC mains: Conforms to EN55011 Group 1 Class B
Applicable standard(SEMI) F47-0706 (200 VAC input)
Ambient temperature Operating: -10 to 70 CELStorage: -25 to 75 CEL(with no icing or condensation)
Ambient humidity Operating: 25 to 85% RHStorage: 25 to 90% RH(With no icing or condensation)
Dielectric strength Between all inputs and all outputs: 3 kVAC for 1 min (Detection current: 20 mA)Between all inputs and PE terminals: 2 kVAC for 1 min (Detection current: 20 mA)Between all outputs and PE terminals: 1 kVAC for 1 min (Detection current: 20 mA)
Insulation resistance Between all outputs and all inputs/ PE terminals: 100 MOhm Min.
Vibration resistance 10 to 55 Hz, 19.6 m/s**2 (2 G) in each 3 directions for 1 hour
Shock resistance 196.1 m/s**2, in each 6 directions 3 times
Heat radiation Natural air-cooling
Construction With chassis and cover
Weight 450 g Max.

Omron Power Supply S8VM Series S8VM-05012
Omron Power Supply S8VM Series S8VM-05012
Standard Type , Open-Frame Type , Bottom Mounting Type , Input 100 to 240 VAC , 50 W , Output 12 V 4.3 APower rating 50 WEfficiency 79% Min.Rated input voltage
Omron Power Supply S8VM Series S8VM-01524C
Omron Power Supply S8VM Series S8VM-01524C
Standard Type , Covered Type , Bottom Mounting Type , Input 100 to 240 VAC , 15 W , Output 24 V 0.65 APower rating 15 WEfficiency 80% Min.Rated input voltage 10
Omron Power Supply S8EX Series S8EX-BP15048LC
Omron Power Supply S8EX Series S8EX-BP15048LC
With chassis and cover , Input 100 to 240 VAC , 150W , Output 48V 3.2APower rating 150 WEfficiency 85% Min. ï¼ˆAt 100 VAC input)88% Min. ï¼ˆAt 200 VAC in
Omron S8JX Switch Mode Power S8JX-G01505CD
Omron S8JX Switch Mode Power S8JX-G01505CD
Covered type , Input 100 to 240 VAC , 15 W , Output 5 V 3 A , DIN Rail mounting typePower rating 15 WEfficiency 68% Min.Rated input voltage 100 to 240 VACA
Omron Power Supply S8VM Series S8VM-10015CD
Omron Power Supply S8VM Series S8VM-10015CD
Standard Type , Covered Type , DIN Rail Mounting Bracket Type , Input 100 to 240 VAC , 100 W , Output 15 V 7 APower rating 100 WEfficiency 81% Min.Rated in
Omron Power Supply S8EX Series S8EX-N01512L
Omron Power Supply S8EX Series S8EX-N01512L
With chassis , Input 100 to 240 VAC , 15W , Output 12V 1.3APower rating 15 WEfficiency 77% Min. ï¼ˆAt 100 VAC input)77% Min. ï¼ˆAt 200 VAC input)Rated i
Omron Power Supply S8JX Switch Mode Power S8JX-P30005C
Omron Power Supply S8JX Switch Mode Power S8JX-P30005C
Covered type , Input 100 to 240 VAC , 300W , Output 5V 60A , Front-mounting typePower rating 300 WEfficiency 75% Min.Rated input voltage 100 to 240 VACAllowable-input voltage&
Omron S8JX Switch Mode Power S8JX-G15048
Omron S8JX Switch Mode Power S8JX-G15048
Open-Frame Type , Input 100 to 240 VAC , 150W , Output 48V 3.3A , Front-mounting typePower rating 150 WEfficiency 85% Min.Rated input voltage 100 to 240 VACAllowable-input vol
Omron Power Supply S8VS Series S8VS-09024AP-F
Omron Power Supply S8VS Series S8VS-09024AP-F
Total Run Time Monitor , Input 100 to 240 VAC , 90 W , Output 24 V 3.75 A , With Undervoltage Alarm (Ttransistor (Sourcing))Power rating 90 WEfficiency 83% TYP. 
Omron Power Supply S8VS Series S8VS-24024B
Omron Power Supply S8VS Series S8VS-24024B
Total Run Time Monitor , Input 100 to 240 VAC , 240 W , Output 24 V 10 APower rating 240 WEfficiency 85% TYP. ï¼ˆAt 100 VAC input)88% TYP. ï¼ˆAt 200