Cart()
 
 
Categories
Contact Us
  • A&S Power Supply Co.,Ltd
  • Address:469, Xinsheng Road, Gaoxin District, Chengdu, Sichuan, China
  • Tel:+86-28-65376776
  • Fax:+86-28-86129221
  • Email:inverter@electrical8.com
  • Contact Person:Karina
Home / Products / power supply / Omron Power Supply / S8JX Switch Mode Power / Omron Power Supply S8JX Switch Mode Power S8JX-G15005D

Omron Power Supply S8JX Switch Mode Power S8JX-G15005D

Omron Power Supply S8JX Switch Mode Power S8JX-G15005D
share

Open-Frame Type , Input Switchable between 100 to 120 VAC and 200 to 240 VAC , 150W , Output 5V 30A , DIN Rail mounting type
Power rating 150 W
Efficiency 78% Min.
Rated input voltage 100 to 120 VAC200 to 240 VAC
Allowable-input voltage variable range 85 to 132 VAC170 to 264 VAC
Frequency 50/60 Hz (47 to 450 Hz Single-phase)
Rated input current 3.5 A Max. ï¼ˆAt 100 VAC input)2.1 A Max. ï¼ˆAt 200 VAC input)
Leakage current 0.5 mA Max. (At 100 VAC input)1 mA Max. (At 200 VAC input)
Inrush current 20 A Max. ï¼ˆAt 100 VAC input (For cold start at 25 CEL))40 A Max. ï¼ˆAt 200 VAC input (For cold start at 25 CEL))
Rated output voltage 5 VDC
Output voltage variable range -10 to +15% (With V. ADJ)(If the output voltage adjuster (V. ADJ) is turned, the voltage will increase by more than the allowable voltage range. When adjusting the output voltage, confirm the actual output voltage from the Power Supply and be sure that load is not damaged.)
Ripple 2%(p-p) Max. (Under the rated I/O conditions.)
Static input variation influence 0.4% Max.
Static load variation influence 0.8% Max. (At rated input, 0 to 100% load)
Ambient temperature variation influence 0.05 %/CEL Max. (At rated input/output voltage)
Rated output current 30 A
Start up time 500 ms Max. ï¼ˆUp to 90% of output voltage at rated input and output)
Hold time 20 ms Min. (At rated input voltage: 100 or 200 VAC at 100% load.)
Overload protection 105% to 175% of the rated output currentVoltage drop, Automatic reset
Overvoltage protection Operated at 120 to 140 % of the rated output voltage, Shut-offResetting: Reset the power by turning it back (OFF time: at least 7 min)
Overheat protection No
Maintenance forecast monitor output No
Total run time monitor output No
Undervoltage alarm output No
Power failure alarm output No
Parallel operation No (However, backup operation is possible; external diodes required.)
Series operation Yes (Up to 2 Power Supplies with external diode)
Remote sensing function No
Applicable standard (UL) Standard No.: UL Listed: UL508 (Listing), UL UR: UL60950-1 (Recognition)
Applicable standard (CSA) Standard No.: cUL Listed: CSA C22.2 No.107.1, cUR: CSA C22.2 No.60950-1
Applicable standard (EN) Standard No.: EN50178, EN60950-1
Applicable standard (EC Directive (EMI)) Emission Enclosure: Conforms to EN55011 Group 1 Class AEmission AC mains: Conforms to EN55011 Group 1 Class A and based on FCC Class AEMS: EN61204-3 High severity levels
Applicable standard(VDE) Standard No.: VDE0160, VDE0805 Teil 1 File number:
Applicable standard(Other) Conformed standard 2: Terminal block: Based on DIN EN50274 (VDE0660-514)
Ambient temperature Operating: -10 to 60 CELStorage: -25 to 65 CEL(with no icing or condensation)
Ambient humidity Operating: 25 to 85%Storage: 25 to 90%(With no icing or condensation)
Dielectric strength Between all inputs and all outputs: 3 kVAC for 1 min (Detection current: 20 mA)Between all inputs and PE terminals: 2 kVAC for 1 min (Detection current: 20 mA)Between all outputs and PE terminals: 1 kVAC for 1 min (Detection current: 20 mA)
Insulation resistance Between all outputs and all inputs/ PE terminals: 100 MOhm Min. (at 500 VDC)
Vibration resistance 10 to 55 Hz, 0.375 mm single amplitude in each 3 directions for 2 hours
Shock resistance 150 m/s**2, in each 6 directions 3 times
Output indicator Yes (color: green)
Heat radiation Natural air-cooling
Construction Open-frame type
Terminal type Screw terminal
Mounting type DIN Rail mounting type

Omron Power Supply S8JX Switch Mode Power S8JX-P15024CD
Omron Power Supply S8JX Switch Mode Power S8JX-P15024CD
Covered type , Input 100 to 240 VAC , 150W , Output 24V 6.5A , DIN Rail mounting typePower rating 150 WEfficiency 81% Min.Rated input voltage 100 to 240 VACAllowable-inpu
Omron Power Supply S82S S82S-7312
Omron Power Supply S82S S82S-7312
Input 12 to 24 VDC , 3 W , Output 12 V 0.25 APower rating 3 WEfficiency 60% Min.Rated input voltage 12 to 24 VDCAllowable-input voltage variable range 10.2 to 27.6 V
Omron Power Supply S8EX Series S8EX-BP15012
Omron Power Supply S8EX Series S8EX-BP15012
Open type , Input 100 to 240 VAC , 150W , Output 12V 12.5APower rating 150 WEfficiency 83% Min. ï¼ˆAt 100 VAC input)86% Min. ï¼ˆAt 200 VAC input)Rated i
Omron Power Supply S8VM Series S8VM-05024C
Omron Power Supply S8VM Series S8VM-05024C
Standard Type , Covered Type , Bottom Mounting Type , Input 100 to 240 VAC , 50 W , Output 24 V 2.2 APower rating 50 WEfficiency 80% Min.Rated input voltage 100
Omron Power Supply S8JX Switch Mode Power S8JX-P30024CD
Omron Power Supply S8JX Switch Mode Power S8JX-P30024CD
Covered type , Input 100 to 240 VAC , 300W , Output 24V 14A , DIN Rail mounting typePower rating 300 WEfficiency 79% Min.Rated input voltage 100 to 240 VACAllowable-input
Omron S8JX Switch Mode Power S8JX-G15048
Omron S8JX Switch Mode Power S8JX-G15048
Open-Frame Type , Input 100 to 240 VAC , 150W , Output 48V 3.3A , Front-mounting typePower rating 150 WEfficiency 85% Min.Rated input voltage 100 to 240 VACAllowable-input vol
Omron Power Supply S8VS Series S8VS-18024BE
Omron Power Supply S8VS Series S8VS-18024BE
Total Run Time Monitor , Input 100 to 240 VAC , 180 W , Output 24 V 7.5 APower rating 180 WEfficiency 85% TYP. ï¼ˆAt 100 VAC input)87% TYP. ï¼ˆAt 200 
Omron Power Supply S8JX Switch Mode Power S8JX-P15005D
Omron Power Supply S8JX Switch Mode Power S8JX-P15005D
Open-Frame Type , Input 100 to 240 VAC , 150W , Output 5V 30A , DIN Rail mounting typePower rating 150 WEfficiency 79% Min.Rated input voltage 100 to 240 VACAllowable-inp
Omron Power Supply S8EX Series S8EX-BP10048LC
Omron Power Supply S8EX Series S8EX-BP10048LC
With chassis and cover , Input 100 to 240 VAC , 100W , Output 48V 2.1APower rating 100 WEfficiency 84% Min. ï¼ˆAt 100 VAC input)86% Min. ï¼ˆAt 200 VAC in
Omron S8JX Switch Mode Power S8JX-G05024CD
Omron S8JX Switch Mode Power S8JX-G05024CD
Covered type , Input 100 to 240 VAC , 50 W , Output 24 V 2.1 A , DIN Rail mounting typePower rating 50 WEfficiency 83% Min.Rated input voltage 100 to 240 V