Technical Specifications:
ELECTRICAL INPUT
Voltage 120 and 230 VAC nominal;
Online Voltage -30%, +20% for nominal voltages; user-selectable
Range extended range of -35%, +20% (-30%, +15% for 127
and 240 VAC)
Nominal Input 50/60 Hz; auto-selection (60 Hz only for 120 and 127 Vac)
Frequency
Frequency Tolerance Nominal ±3 Hz
ELECTRICAL OUTPUT
Power Levels 1000 – 3000 VA
Online Regulation -10%, +6%; within Computer Business Equipment
Manufacturers Association's Guidelines (-15%;
+10% using extended range)
On Battery Regulation <±5% RMS
Voltage Wave Shape Sine wave, 3% THD

Powerware BPII HE UPS 10 kVA/8 kw
Powerware BPII HE UPS 10 kVA/8 kw
Descriptions:Balanced Power II HE and Balanced Power II-S HE (BPII HE and BPII-S HE) offer the reliability of true online technology utilizing digital signal processing (DSP) control and monitoring. In addition, the BPII HE and BPII-S HE use the patented technology of an inverter software harmonic c
Powerware 5119 UPS PW5119 3000i
Powerware 5119 UPS PW5119 3000i
Technical Specifications:ELECTRICAL INPUTVoltage 120 and 230 VAC nominal;Online Voltage -30%, +20% for nominal voltages; user-selectableRange extended range of -35%, +20% (-30%, +15% for 127and 240 VAC)Nominal Input 50/60 Hz; auto-selection (60 Hz only for 120 and 127 Vac)FrequencyFrequency Toleranc
Powerware BPII HE UPS 30 kVA/24 kw
Powerware BPII HE UPS 30 kVA/24 kw
Descriptions:Balanced Power II HE and Balanced Power II-S HE (BPII HE and BPII-S HE) offer the reliability of true online technology utilizing digital signal processing (DSP) control and monitoring. In addition, the BPII HE and BPII-S HE use the patented technology of an inverter software harmonic c
Powerware 5125 RM UPS 51253000ERMBLK
Powerware 5125 RM UPS 51253000ERMBLK
Technical SpecificationsRating 3000VACapacity (VA/watts)3000/2700Dimensions WxDxH (mm) 483x622x89 Weight (kg) 46Input connection IEC320/16AOutput connection 9 x IEC320/10A1 x IEC320/16ATypical Runtime (full load) pf 0.9 (half load)5 min 15 min
POWERWARE 9150 UPS 12I-N-10
POWERWARE 9150 UPS 12I-N-10
Specifications:Rating 8-15 kVA at computer loadEfficiency Up to 93% onlineAudible noise
Powerware 9170 Online UPS PW12S12K-PD
Powerware 9170 Online UPS PW12S12K-PD
Specifications:Power DescriptionLoad Capacity 12 kVA/8.40 kWInput Voltage 110 V AC220 V ACInput Voltage Range 120 V AC208 V AC240 V ACOutput Voltage 120 V AC208 V AC240 V ACFrequency 50 Hz60 Hz
Powerware 9170 Online UPS PW6S3K-LPD
Powerware 9170 Online UPS PW6S3K-LPD
Specifications:Technical InformationPlug/Connector Type NEMA 14-50PReceptacles 12 x NEMA 5-20R2 x NEMA L6-30R2 x NEMA L14-30RPower DescriptionLoad Capacity 9 kVAInput Voltage 110 V AC/220 V ACInput Voltage Range 208 V AC to 240 V AC/176 V AC to 276 V AC/100 V AC to 127 V AC200 V ACOutput Voltage 200
Powerware 5119 UPS PW5119 2400i
Powerware 5119 UPS PW5119 2400i
Technical Specifications:ELECTRICAL INPUTVoltage 120 and 230 VAC nominal;Online Voltage -30%, +20% for nominal voltages; user-selectableRange extended range of -35%, +20% (-30%, +15% for 127and 240 VAC)Nominal Input 50/60 Hz; auto-selection (60 Hz only for 120 and 127 Vac)FrequencyFrequency Toleranc
Powerware 3110 UPS PW3110 700
Powerware 3110 UPS PW3110 700
Descriptions:Ideal for PC-based applications, the Powerware 3110 provides affordable protection in a sleek, well-designed unit that can fit undera desk or can be wall-mounted.
Powerware 5119 UPS PW5119 2000i
Powerware 5119 UPS PW5119 2000i
Technical Specifications:ELECTRICAL INPUTVoltage 120 and 230 VAC nominal;Online Voltage -30%, +20% for nominal voltages; user-selectableRange extended range of -35%, +20% (-30%, +15% for 127and 240 VAC)Nominal Input 50/60 Hz; auto-selection (60 Hz only for 120 and 127 Vac)FrequencyFrequency Toleranc