Specifications:
Input Specifications
Frequency range (60 Hz) 57-63 Hz (50 Hz) 47-53 Hz
Power factor 0.95 typical at full load with input filter
Input current Less than 7% with input filter distortion
Output Specifications
Voltage THD Less than 3% for 100% linear load.
Less than 5% for 100% non-linear
load when tested in accordance with EN50091-3
Voltage regulation Better than ±1%
Frequency (free run) ±0.005 Hz
Frequency sync range ±0.5 Hz
Frequency slew rate 1 Hz/second maximum

POWERWARE 9150 UPS 10I-S-7
POWERWARE 9150 UPS 10I-S-7
Specifications:Rating 8-15 kVA at computer loadEfficiency Up to 93% onlineAudible noise
Powerware BPII-S HE UPS 30 kVA/24 kw
Powerware BPII-S HE UPS 30 kVA/24 kw
Descriptions:Balanced Power II HE and Balanced Power II-S HE (BPII HE and BPII-S HE) offer the reliability of true online technology utilizing digital signal processing (DSP) control and monitoring. In addition, the BPII HE and BPII-S HE use the patented technology of an inverter software harmonic c
Powerware 9125 Rackmount UPS 91252000iRM
Powerware 9125 Rackmount UPS 91252000iRM
Specifications:Rating 2000VA Capacity (VA/Watts) 2000/1400Dimensions WxDxH (mm) 432x490x89 Weight (kg) 23 Input Connection IEC320/10AOutput Connection 6xIEC320 10A OperationalNominal input voltage (Vac) 220/230/240 VacInput voltage range 160-288 VAC
Powerware 9305 UPS PW9305-40I-NX
Powerware 9305 UPS PW9305-40I-NX
Specifications:Rating 40 kVA Capacity (VA/Watts) 40 kVA/28 kWDimensions WxDxH (mm) 520x788x1530Weight (kg) 230 Input connection Hardwired Output connection HardwiredTypical runtime (Full load) 10 min (Half load) 25 min
Powerware BPIII HE UPS 62.5 kVA/50 kw
Powerware BPIII HE UPS 62.5 kVA/50 kw
Specifications:Configuration: 3-Phase, 3 wire plus groundRange Nominal +10%, –15%Frequency range Nominal ±3 Hz (60 Hz)Power factor Minimum 0.9 with filterPower walk-in 3-60 seconds to full loadInput current 10% THD under nominal conditions distortion with filterTransient protection 6kV OC, 3 kV S
Powerware 5119 Rackmount UPS PW5119 1000RM
Powerware 5119 Rackmount UPS PW5119 1000RM
Specifications:Electrical InputVoltage 120 and 230 VAC NominalOn Line Voltage Range -30%, +20% for nominal voltages; user selectable extended range of -35%, +20% (-30%, +15% for 127 and 240 VAC)Nominal Input Frequency 50/60 Hz; auto-selection (60 Hz only for 120 and 127 VAC)Frequency Tolerance No
Eaton Powerware 5110 UPS 51100350A
Eaton Powerware 5110 UPS 51100350A
Specifications:Capacity 350VA/210W Dimensions (mm) HxWxD 270x87x260Unit Weight (kg) 5 6 8 12 12.5Input Connection 1.8 metre line cord IEC to Australian 10Amp PlugOutput Connection 6 Australian 10Amp Outlets (3 Battery Backup & Surge Protection,3 Surge Protection only)OperationInput Voltage Range (on
Powerware BPIII Industrial UPS 30-160 KVA
Powerware BPIII Industrial UPS 30-160 KVA
Specifications:Configuration 3-phase, 3-wire plus groundRange Nominal +10%, -15%Frequency range Nominal ±3 Hz (60 Hz)Power factor Minimum 0.9with filterPower walk-in 3 to 60 seconds to full loadInput current 10% THD under nominal conditionsdistortion with filterTransient protection 6 kV OC, 3 kA pe
Powerware 5119 UPS PW5119 1000
Powerware 5119 UPS PW5119 1000
Technical Specifications:ELECTRICAL INPUTVoltage 120 and 230 VAC nominal;Online Voltage -30%, +20% for nominal voltages; user-selectableRange extended range of -35%, +20% (-30%, +15% for 127and 240 VAC)Nominal Input 50/60 Hz; auto-selection (60 Hz only for 120 and 127 Vac)FrequencyFrequency Toleranc
Powerware BPIII HE UPS 75 kVA/60 kw
Powerware BPIII HE UPS 75 kVA/60 kw
Specifications:Configuration: 3-Phase, 3 wire plus groundRange Nominal +10%, –15%Frequency range Nominal ±3 Hz (60 Hz)Power factor Minimum 0.9 with filterPower walk-in 3-60 seconds to full loadInput current 10% THD under nominal conditions distortion with filterTransient protection 6kV OC, 3 kV S