INPUT
Rated power 120000 VA
Voltage 400 Vac three-phase Vac
Voltage tolerance + 20% - 25%
Frequency 50/60 Hz with autorange
Frequency tolerance 45/65 Hz
Power factor 0,99
Input current 169 A
Current distorsion <3%
Soft start 0-100% in 10
BY PASS
Rated voltage 400 Vac three-phase selectable 380 and 415
Voltage tolerance ± 15% (selectable from ± 10% to ± 25% from front panel)
Rated frequency 50/60 Hz (autorange)
Frequency tolerance ± 2% (selectable from ± 1% to ± 5% from front panel)
Rated current 169 A
Number phases 3
Back-feed protection yes
Overload capacity Inx10ms 14
OUTPUT and INVERTER OUTPUT
Rated power 120000 VA
Active power 120000 W
Number phases 3 + N
Crest factor (Ipeak/Irms) 3 : 1
Waveform Sinewave
Dynamic stability ± 5% in 5 ms
Frequency same as the input (autorange)
Voltage distortion with distorcing load <3%
Voltage distortion with linear load <1%
Frequency stability ± 0,05% on mains failure ± 2% (selectable from ± 1% to ± 5% from front panel) with mains supply present
Overload 125% 150% 200% of the rated current for 10' / 1' / 7

Riello Multi Sentry UPS MSM 15
Riello Multi Sentry UPS MSM 15
Specifications:INPUTRated power 15000 VAVoltage 230 Vac single-phase or 400 Vac three-phase + N VacVoltage tolerance ± 20%Frequency tolerance 40/72 HzPower factor 0.99BY PASSRated voltage 230Voltage tolerance ± 15% (selectable from ± 5% to ± 25%)Rated frequency 50/60 HzFrequency tolerance ± 5%
Riello Multi Sentry UPS MSM 12
Riello Multi Sentry UPS MSM 12
Specifications: INPUT Rated power 12000 VA Voltage 230 Vac single-phase or 400 Vac three-phase + N Vac Voltage tolerance ± 20% Frequency tolerance 40/72 Hz Power factor 0.99 BY PASS Rated voltage 230 Voltage tolerance ± 15% (selectable from ± 5% to ± 25%) Rated frequency 50/60 Hz Freq
Riello Multi Sentry UPS MCT 20
Riello Multi Sentry UPS MCT 20
Specifications:INPUTRated power 20000 VAVoltage 400 Vac three-phase + N VacVoltage tolerance ± 20%Frequency tolerance 40/72 HzPower factor 0.99BY PASSRated voltage 400Voltage tolerance ± 15% (selectable from ± 5% to ± 25%)Rated frequency 50/60 HzFrequency tolerance ± 5% (selectable from ± 0.25
Riello Multi Sentry UPS MCT 15
Riello Multi Sentry UPS MCT 15
Specifications:INPUTRated power 15000 VAVoltage 400 Vac three-phase + N VacVoltage tolerance ± 20%Frequency tolerance 40/72 HzPower factor 0.99BY PASSRated voltage 400Voltage tolerance ± 15% (selectable from ± 5% to ± 25%)Rated frequency 50/60 HzFrequency tolerance ± 5% (selectable from ± 0.25
Riello Multi Sentry UPS MST 80
Riello Multi Sentry UPS MST 80
Specifications:INPUTINPUTRated power 80000 VAVoltage 400 Vac three-phase + N VacVoltage tolerance ± 20%Frequency tolerance 40/72 HzPower factor 0.99BY PASSRated voltage 400Voltage tolerance ± 15% (selectable from ± 5% to ± 25%)Rated frequency 50/60 HzFrequency tolerance ± 5% (selectable from ±
Riello Sentinel Dual (Low Power) UPS SDH 1000
Riello Sentinel Dual (Low Power) UPS SDH 1000
Specifications:INPUTRated power 1000 VAVoltage 220-230-240 VacVoltage tolerance 140 Vac < Vin < 276 Vac @50% LOAD / 184 Vac < Vin < 276 Vac @ 100% LOADFrequency 50/60 HzFrequency tolerance 50 Hz ± 5% / 60 Hz ± 5%Power factor > 0.99Current distorsion ≤7%BY PASSVoltage tolerance 180 - 264Frequency
Riello Sentinel Power Green UPS SPH 10
Riello Sentinel Power Green UPS SPH 10
Specifications:INPUTVoltage 220-230-240 VacFrequency 50/60 Hz +/- 10 HzBY PASSVoltage tolerance 160 - 276 Vac (selectable in Economy Mode or Smart Active Mode)Frequency tolerance Selected frequency ±10%OUTPUT and INVERTER OUTPUTRated power 10000 VAActive power 9000 WWaveform SinusoidalOVERLOAD TIME
Riello Master HP UPS MHT 100
Riello Master HP UPS MHT 100
SpecificationsINPUTRated power 100000 VAVoltage 400 Vac three-phase VacVoltage tolerance + 20% - 25%Frequency 50/60 Hz with autorangeFrequency tolerance 45/65 HzPower factor 0,99Input current 141 ACurrent distorsion
Riello Sentinel Dual (Low Power) UPS SDH 2200 ER
Riello Sentinel Dual (Low Power) UPS SDH 2200 ER
Specifications:INPUTRated power 2200 VAVoltage 220-230-240 VacVoltage tolerance 140 Vac < Vin < 276 Vac @50% LOAD / 184 Vac < Vin < 276 Vac @ 100% LOADFrequency 50/60 HzFrequency tolerance 50 Hz ± 5% / 60 Hz ± 5%Power factor > 0.99Current distorsion ≤7%BY PASSVoltage tolerance 200 - 253Frequency
Rielloi Dialog Rack UPS IDR 600
Rielloi Dialog Rack UPS IDR 600
Specifications:INPUTRated power 600 VAVoltage 220-240 VacVoltage tolerance 230 Vac (+ 20 / - 25%)Frequency 50/60 Hz auto sensingOUTPUT and INVERTER OUTPUTRated power 600 VAActive power 360 WNumber phases 1Wave form on battery Pseudo sinewaveFrequency on battery operation 50 or 60 Hz (± 1%)BATTERIES